STATUS LED Indicators
Table 15. STATUS LED Indicators
LED Pattern
Indication
Blinks twice and
pauses
The sbRIO-96xx is in safe mode. Software is not installed, which is
the factory default state, or software has been improperly installed on
the sbRIO-96xx.
An error can occur when an attempt to upgrade the software is
interrupted. Reinstall software on the sbRIO-96xx. Refer to the
Measurement & Automation Explorer (MAX) Help
for information
about installing software on the sbRIO-96xx.
Blinks three times
and pauses
The sbRIO-96xx is in user-directed safe mode, or the sbRIO-96xx is
in install mode to indicate that software is currently being installed.
This pattern may also indicate that the user has forced the sbRIO-96xx
to boot into safe mode by pressing the reset button for longer than five
seconds or by enabling safe mode in MAX. Refer to the
Measurement
& Automation Explorer (MAX) Help
for information about safe mode.
Blinks four times
and pauses
The sbRIO-96xx is in safe mode. The software has crashed twice
without rebooting or cycling power between crashes.
Continuously blinks The sbRIO-96xx has not booted into NI Linux Real-Time. The
sbRIO-96xx either booted into an unsupported operating system, was
interrupted during the boot process, or detected an unrecoverable
software error.
On momentarily
The sbRIO-96xx is booting. No action required.
Off
The sbRIO-96xx is in run mode. Software is installed and the
operating system is running.
User LEDs
Note
You can define the USER1 and USER FPGA1 LEDs to meet the needs of
your application.
CompactRIO Single-Board Controller with NI-DAQmx Hardware Installation Manual
|
© National Instruments
|
25