1-12
|
ni.com
Chapter 1
Getting Started with the cDAQ Chassis
Panel Mounting without a Panel Mount Kit
You can mount the cDAQ chassis directly on a flat surface using the mounting holes. Align the
chassis on the surface. Then, fasten the chassis to the surface using three M4 or No. 8 panhead
screws as shown in Figure 1-11. National Instruments does not provide these screws with the
chassis.
Figure 1-11.
Mounting the cDAQ Chassis Directly on a Flat Surface
Refer to the
NI cDAQ-9179 Specifications
for mounting dimensions.
Caution
Make sure that no C Series modules are in the chassis before removing it
from the surface.
Mounting the cDAQ Chassis on a DIN Rail
Use the NI 9916 DIN rail kit (part number 780982-01) to mount the NI cDAQ-9179 chassis on
a DIN rail.
Each DIN rail kit contains one clip three
M4
×
22
screws for mounting the chassis on a standard
35 mm DIN rail. To mount the chassis on a DIN rail, fasten the DIN rail clip to the chassis using
a number 2 Phillips screwdriver and three
M4
×
22
screws. Make sure the DIN rail kit is installed
as illustrated in Figure 1-12, with the larger lip of the DIN clip positioned up. When the DIN rail
kit is properly installed, the cDAQ chassis is centered on the DIN rail.