National Instruments BNC-2142 Installation Manual Download Page 4

BNC-2142 Installation Guide

4

www.natinst.com

Installing Your BNC-2142

Perform the following steps to connect your BNC-2142 to your DSA 
device. Consult your computer user manual or technical reference manual 
for specific instructions and warnings.

Note

You can either place the BNC-2142 on a workbench near the host computer or use 

the available DIN rail-mount kit.

1.

Connect the BNC-2142 to your DSA device.

2.

Connect the field signals to the BNC connectors. Refer to the 
Connecting Signals to Your BNC-2142 section earlier in this guide for 
more information.

When you have finished using your BNC-2142, turn off any powered 
external signals connected to your BNC-2142 before you turn off your 
computer.

Figure 1.  

Connecting the BNC-2142 to Your DSA Device

Warning

The BNC-2142 is not designed for input voltages greater than ±42.4 V, even if a 

user-installed voltage divider reduces the voltage to within the input range of the DSA 
device. Input voltages greater than ±42.4 V can damage the BNC-2142, any device 
connected to it, and the host computer. Overvoltage can also cause an electric shock hazard 
for the operator. National Instruments is not liable for damage or injury resulting from such 
misuse.

1

BNC-2142

2

Shielded Cable

3

DSA Device

4

Personal Computer

3

4

1

2

Summary of Contents for BNC-2142

Page 1: ... adapter you can connect directly to dynamic signal acquisition DSA devices It includes six BNC connectors for signal connections and a 68 pin I O connector for connection to the PCI 445x and NI 455x DSA devices The BNC 2142 is ideal for simplifying connections between your measurement apparatus and your DSA device in laboratory test and production environments What You Need to Get Started To set ...

Page 2: ...round Additionally if the source or load ground is at a different electrical potential than the ground of the BNC 2142 and DSA device ground loops may occur that can result in incorrect readings and may damage the BNC 2142 the DSA device or the host computer National Instruments is not liable for damage resulting from these connections To avoid encountering these conditions electrically isolate or...

Page 3: ... BNC 2142 connects to the analog output channels on the PCI 445x and NI 455x DSA devices via the DAC0OUT and DAC1OUT BNC connectors Cabling The BNC 2142 has one 68 position 0 8 mm VHDCI connector on the rear panel to connect to your DSA device Caution Do not connect the BNC 2142 to any device other than the National Instruments PCI 445x and NI 455x DSA devices Doing so can damage the BNC 2142 the ...

Page 4: ...guide for more information When you have finished using your BNC 2142 turn off any powered external signals connected to your BNC 2142 before you turn off your computer Figure 1 Connecting the BNC 2142 to Your DSA Device Warning The BNC 2142 is not designed for input voltages greater than 42 4 V even if a user installed voltage divider reduces the voltage to within the input range of the DSA devic...

Page 5: ...ge Each input should remain within 42 4 V 30 Vrms of ground Field connection 6 BNC connectors 4 single ended analog input connectors and 2 single ended analog output connectors Physical Dimensions 14 4 by 11 2 by 5 5 cm 5 7 by 4 4 by 2 2 in I O connector One 68 pin 0 8 mm VHDCI female connector BNC connectors 6 Environment Operating temperature 0 to 70 C Storage temperature 55 to 150 C Relative hu...

Page 6: ......

Reviews: