Connecting Differential Analog Input Signals

Complete the following steps to measure a differential (DIFF) analog input 
signal.

1.

Connect the BNC cable to one of the AI <0..7> BNC connectors on the 
front panel. 

Do not connect anything to the corresponding AI <8..15> BNC 
connector below the AI <0..7> BNC connector you use.

2.

Move the corresponding SE/DIFF switch to the DIFF position. On the 
BNC-2090A front panel, a line indicates which SE/DIFF switch 
corresponds to each AI <0..7> BNC connector.

3.

Configure your software to measure this channel differentially.

Figure 3 shows how differential AI signals are routed to the DAQ device.

Figure 3.  

Analog Input Differential Mode

Cable

Do Not

Connect

BNC-2090A

AI 0

SE

DIFF

AI 8

RSE/NRSE

Switch

Not Used

RSE

NRSE

AI 0

DAQ Device

AI 8

Summary of Contents for BNC-2090A

Page 1: ...Refer to the BNC 2090A User Manual for in depth information about accessory installation cable connections jumper settings signals and signal conditioning as well as accessory specifications Figure 1...

Page 2: ...gure 2 Connecting the BNC 2090A to Your DAQ Device 1 Place the BNC 2090A near the host computer or mount the BNC 2090A into a 19 inch rack If you do not rack mount the accessory attach the four adhesi...

Page 3: ...ltage to within the input range of the DAQ device Input voltages greater than 42 4 Vpk 60 VDC can damage the BNC 2090A all devices connected to it and the host computer Overvoltage can also cause an e...

Page 4: ...connector below the AI 0 7 BNC connector you use 2 Move the corresponding SE DIFF switch to the DIFF position On the BNC 2090A front panel a line indicates which SE DIFF switch corresponds to each AI...

Page 5: ...sponds to each AI 0 15 BNC connector 3 Move the RSE NRSE switch to select how the ground signal is routed All single ended signals share the one RSE NRSE switch For more information about non referenc...

Page 6: ...nd PFI 0 signals are routed to the DAQ device Figure 5 Analog Output APFI 0 and PFI 0 Connecting Digital Signals Use the BNC 2090A spring terminal block on the front panel to connect digital signals t...

Page 7: ...e 6 USER 1 2 BNC Connections Figure 7 shows an example of how to use the USER 1 2 BNCs To access the PFI 5 signal from a BNC connect USER1 on the spring terminal block to PFI 5 with a wire Figure 7 Co...

Page 8: ...ion Help Patents in your software the patents txt file on your CD or ni com patents 2006 National Instruments Corporation All rights reserved 371877A 01 Dec06 Where to Go from Here Refer to the BNC 20...

Reviews: