3. Move the IP RESET and SAFE MODE switches to the OFF position.
4. Configure the IP and other network settings in MAX.
Caution
If the chassis is restored to the BIOS network settings, the LabVIEW
run-time engine does not load. You must reconfigure the network settings and
restart the chassis for the LabVIEW run-time engine to load.
NI 9148 Specifications
This document lists the specifications for the NI 9148 Ethernet Expansion Chassis. The
following specifications are typical for the -40 °C to 70 °C operating temperature range unless
otherwise noted.
Caution
Do not operate the NI 9148 in a manner not specified in this document.
Product misuse can result in a hazard. You can compromise the safety protection
built into the product if the product is damaged in any way. If the product is
damaged, return it to NI for repair.
Network
Network interface
10BaseT and 100BaseTX Ethernet
Compatibility
IEEE 802.3
Communication rates
10 Mbps, 100 Mbps, auto-negotiated
Maximum cabling distance
100 m/segment
Reconfigurable FPGA
Type
Xilinx Spartan-3 2M
Number of logic cells
46,080
Available embedded RAM
720 kbits
Power Requirements
Voltage input range
19 V to 30 V
Maximum power input
20 W maximum
Maximum power consumption
20 W maximum
Physical Characteristics
If you need to clean the NI 9148, wipe it with a dry towel.
Tip
For two-dimensional drawings and three-dimensional models of the NI 9148,
visit
and search by module number.
Weight (unloaded)
929 g (32.7 oz)