16
|
ni.com
|
Getting Started with NI 9501 Modules and NI SoftMotion
Figure 14 shows the parts of the
Axis Configuration
dialog box for NI 9501 UDV axes.
Refer to the
NI SoftMotion Module
section of the
LabVIEW Help
for detailed information
about each configuration option.
Figure 14.
Axis Configuration Dialog Box for NI 9501 UDV Axes
Note
The
Axis Configuration
dialog box user interface may not match this image
exactly depending on which version of the LabVIEW NI SoftMotion Module you are
using.
2.
Click the
Motor
button (
) and set the
Rated Phase Current
to the appropriate value
for your motor in Amps/Phase. Use the motor datasheet and the type of motor connection
used to determine this setting based on the following table.
3.
Click
OK
to close the
Axis Configuration
dialog box.
4.
Right-click the
Chassis
item in the
Project Explorer
window and select
Deploy
from the
shortcut menu.
Table 2.
NI 9501 Rated Phase Current Setting
Connection Type
Rated Phase Current (Amps/Phase)
Bipolar 4-wire
same as datasheet Amps/Phase
6-wire series
datasheet Amps/Phase
×
0.707
6-wire half-coil
same as datasheet Amps/Phase
8-wire series
datasheet Amps/Phase
×
0.707
8-wire parallel
datasheet Amps/Phase
×
1.414
8-wire half coil
same as datasheet Amps/Phase