background image

Table 1.

 FlexRIO Documentation Locations and Descriptions (Continued)

Document

Location

Description

 

 

 

Specifications
document for your
adapter module

Available from the Start menu
and at 

ni.com/manuals

.

Contains specifications for your
adapter module.

LabVIEW FPGA
Module Help

Embedded in 

LabVIEW Help

and at 

ni.com/manuals

.

Contains information about the
basic functionality of the
LabVIEW FPGA Module.

Real-Time Module
Help

Embedded in 

LabVIEW Help

and at 

ni.com/manuals

.

Contains information about real-
time programming concepts, step-
by-step instructions for using
LabVIEW with the Real-Time
Module, reference information
about Real-Time Module VIs and
functions, and information about
LabVIEW features on real-time
operating systems.

FlexRIO Help

Available from the Start menu
and at 

ni.com/manuals

.

Contains information about the
FPGA module front panel
connectors and I/O, controller for
FlexRIO front panel connectors
and I/O, programming
instructions, and adapter module
component-level IP (CLIP).

FlexRIO Adapter
Module Development
Kit User Manual

Available from the Start menu
at 

Start

»

All Programs

»

National Instruments

»

NI

FlexRIO

»

NI FlexRIO

Adapter Module Development
Kit

»

Documentation

.

Contains information about how
to create custom adapter modules
for use with FlexRIO FPGA
modules.

LabVIEW Examples

Available in NI Example
Finder. In LabVIEW, click

Help

»

Find Examples

»

Hardware Input and Output

»

FlexRIO

.

Contains examples of how to run
FPGA VIs and Host VIs on your
device.

NI 5783 Getting Started Guide

  | 

© National Instruments

  | 

3

Summary of Contents for 5783

Page 1: ...ants The NI 5783 features 4 analog input channels with 16 bit resolution and sample rates up to 100 MS s and 4 analog output channels with 16 bit resolution and sample rates up to 100 MS s or 200 MS s Note The NI 5783 is compatible only with NI PXIe 797xR and NI 793xR devices This document explains how to install and configure the NI 5783 Contents Electromagnetic Compatibility Guidelines 2 FlexRIO...

Page 2: ...hermore any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Caution To ensure the specified EMC performance the length of all I O cables must be no longer than 3 m 10 ft FlexRIO Documenta...

Page 3: ...nd information about LabVIEW features on real time operating systems FlexRIO Help Available from the Start menu and at ni com manuals Contains information about the FPGA module front panel connectors and I O controller for FlexRIO front panel connectors and I O programming instructions and adapter module component level IP CLIP FlexRIO Adapter Module Development Kit User Manual Available from the ...

Page 4: ...ion To prevent ESD from damaging the devices ground yourself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove each module from the package and inspect it for loose components or any other sign of damage Caution Never touch the exposed pins of connectors Note Do not install a device ...

Page 5: ...rams about which devices reside in the system and how they are configured MAX is automatically installed with FlexRIO Support 1 Launch MAX by navigating to Start All Programs National Instruments NI MAX or by clicking the NI MAX desktop icon 2 In the Configuration pane double click Devices and Interfaces to see the list of installed devices Installed devices appear under the name of their associat...

Page 6: ... be used with the SCB 19 shielded desktop connector block Refer to the SCB 19 User Guide for information about how to connect and use the SCB 19 with the AUX I O front panel connector on your NI 5783 Related Information AUX I O Connector on page 8 Front Panel and Connector Pinouts The following figure shows the front panel connectors for the NI 5783 6 ni com NI 5783 Getting Started Guide ...

Page 7: ...ut TRIG Trigger input and output channel AUX I O Digital I O and PFI connector Caution To avoid permanent damage to the NI 5783 disconnect all signals connected to the NI 5783 before powering down the module and connect signals only after the adapter module has been powered on by the FlexRIO FPGA module or Controller for FlexRIO Caution Connections that exceed any of the maximum ratings of any con...

Page 8: ...DIO data channel 8 GND Ground reference for signals 9 DIO Port 1 1 Bidirectional SE DIO data channel 10 DIO Port 1 2 Bidirectional SE DIO data channel 11 GND Ground reference for signals 12 DIO Port 1 3 Bidirectional SE DIO data channel 13 PFI 0 Bidirectional SE DIO data channel 14 NC No connect 15 PFI 1 Bidirectional SE DIO data channel 16 PFI 2 Bidirectional SE DIO data channel 17 GND Ground ref...

Page 9: ...CXO Loop Filter PLL Phase Freq Adjust DAC Ch A Ch A DACCLK DATACLK 2 DACCLK Ch A Ch B Ch C Ch D Ch B Ch B DAC3484 QUAD 16 bit 1 25 GSPS DAC AD9511 Clock Distribution PLL 1 W Max Power Supplies 100 MS s Data Rate Interpolate x8 for Fixed Fdac of 800 MS S with Internal PLL Ch C Ch C Ch D Ch D Ch A HDMI DIO Ch A DATACLK 4 SAMPLECLK SAMPLECLK Ch B Ch B AD9653 QUAD 16 bit 125 MSPS ADC Clock at 100 MS S...

Page 10: ... also allows the CLIP to communicate directly with circuitry external to the FPGA Adapter module socketed CLIP allows your IP to communicate directly with both the FPGA VI and the external adapter module connector interface The FlexRIO adapter module ships with socketed CLIP items that add module I O to the LabVIEW project NI 5783 CLIP This CLIP provides access to four 16 bit 100 MS s analog input...

Page 11: ...an be written four samples at a time in the Data Clock domain with 2x interpolation or two samples at a time in the Data Clock 2x domain with 2x interpolation In addition the two analog output channels are provided through channels 1 and 2 of the front panel This CLIP also provides a User Command Interface to configure the clock selection Internal Sample Clock Free Running Internal Sample Clock lo...

Page 12: ... with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration NI corporate h...

Page 13: ...our application This item is also installed with the driver software Support ni com support Located at ni com manuals FlexRIO ni com flexrio Services ni com services Located at ni com gettingstarted Available from the Start menu NI 5783 Specifications FlexRIO Help Getting Started with LabVIEW LabVIEW FPGA Module Help FlexRIO Module Development Kit User Manual NI 5783 Getting Started Guide National...

Page 14: ...d party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Governme...