background image

3

With the burner assembly removed, shine a flash light on 

9. 

the burner ribbons.  Look for carbon buildup, scale, dust, 

lint, and/or anything that might restrict flow through the 

spaces between the burner ribbons.  Holding the burner 

assembly so that any foreign material will fall away from 

the burner, use a stiff bristle brush to loosen and remove 

any foreign materials. 

If the burner is excessively dirty, remove one of the burner end 

caps. Remove the four screws that hold the end cap to the 

burner housing. Lightly tap the end cap to remove it. Clean all 

foreign material from the burner and venturi. After the burner is 

thoroughly clean, replace the end cap making certain that it is 

tight against the burner housing.

NOTE: 

If any of the burner components are damaged or 

deteriorated, replace the burner assembly.

ITEM

DESCRIPTION

PART NO.

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Complete Furnace Assembly 38 Mbh

Complete Furnace Assembly 51Mbh

Complete Furnace Assembly 64 Mbh

Flame Rollout Switch

Orifice Adapter

Orifice Adaptor Lock Nut

DSI Electrode Assembly

Flame Sensor

DSI Integrated Control Board w/Cooling Relay

High Temperature Limit Thermostat

Pressure Switch

High Altitude Pressure Switch

Combination Gas Valve

Venter Tube Assembly

Venter Wheel Motor Assembly

Heat Exchanger Assembly - 38 Mbh
Heat Exchanger Assembly - 51 Mbh
Heat Exchanger Assembly - 64 Mbh

Full Burner Body Assembly - 38 Mbh

Full Burner Body Assembly -51 Mbh

Full Burner Body Assembly - 64 Mbh

Control Plug Assembly (9 wire)

Natural Gas Orifice - 38 Mbh
Natural Gas Orifice - 51 Mbh
Natural Gas Orifice - 64 Mbh

L.P. Gas Orifice - 38 Mbh
L.P. Gas Orifice - 51 Mbh
L.P. Gas Orifice - 64 Mbh

Control Plug Assembly (5 wire)

1/2” 90° Street Elbow Pipe

1/2” 90° Elbow Pipe

1/2” x 8” Black Pipe Threaded Both Ends

14208309
14208308
14208303
14208314
14208315
14208316
14208317
14208318
14208319
14208320
14208324
14208325
14208326
14208327
14208328
14208329
14208330
14208331
14208332
14208333
14208334
14208335
14208336
14208337
14208338
14208339
14208340
14208341
14208342
14208349
14208350
14208351

REPLACEMENT PARTS GUIDE     

      

For proper performance and 

safety, it is important that 

replacement parts be obtained 

from National Comfort Products.  

Please refer to the parts list at 

left for the part numbers:

National Comfort Products

539  Dunksferry Road

Bensalem, PA 19020

(215) 244-1400

1-800-523-7138

Fax: (215) 244-9579

VERIFY PROPER OPERATION AFTER SERVICING.

Summary of Contents for 14208309/HS038

Page 1: ...539 Dunksferry Road Bensalem PA 19020 215 244 1400 1 800 523 7138 Fax 215 244 9579 14299573 03 10 14299575 10 29 2014 National Comfort Products 539 Dunksferry Road Bensalem PA 19020 215 244 1400 1 800...

Page 2: ...FOR MAXIMUM PERFORMANCE IT IS IMPERATIVE THAT THE COOLING CHASSIS AIR DIVIDER BE SEALED TO THE CABINET AIR SEAL ANY LEAKAGE WILL ALLOW OUTSIDE UNCONDITIONED AIR TO INFILTRATE AND MIX WITH THE CONDITIO...

Page 3: ...em Do not modify alter or connect to the vent system in the unit The gas furnace comes completely assembled wired mounted and factory tested inside the Comfort Pack cabinet The furnace includes an int...

Page 4: ...y air duct should be equipped with a removable inspection panel to allow for future inspections of the heat exchanger The Comfort Pack unit contains a 16 x 25 x 1 air filter 12 located on the cooling...

Page 5: ...Integrated Control Board w Cooling Relay High Temperature Limit Thermostat Pressure Switch High Altitude Pressure Switch Combination Gas Valve Venter Tube Assembly Venter Wheel Motor Assembly Heat Ex...

Page 6: ...nd Mtr 230V COIL Fan Herm Compressor C S R Dual Capacitor FLAME SENSOR Roll Out Press Sw To Thermostat Inducer Mtr Contactor RD BK Blue Blue Blue Yellow WT WT BK Y G Red Red White Yellow White Black B...

Page 7: ...ond Mtr 230V COIL Fan Herm Compressor C S R Dual Capacitor FLAME SENSOR Roll Out Press Sw To Thermostat Inducer Mtr Contactor RD BK Blue Blue Blue Blue WT WT BK Y G Red Red White Yellow White Black Bl...

Page 8: ...IZED 7 IF THE FLAME IS EXTINGUISHED DURING MAIN BURNER OPERATION THE INTEGRATED CONTROL SYSTEM CLOSES THE MAIN VALVE AND MUST BE RE 8 SET BY INTERRUPTING POWER TO THE CONTROL CIRCUIT SEE LIGHTING INST...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...COMFORT PACK R 410A Gas Furnace Instructions Rev 14299575 10 29 2014...

Reviews: