background image

 

 

3 Lux Air STYLE 

 

1.

 INSTALLATION INSTRUCTIONS 

 

This air purifier is applicable to homerooms and offices. It can be used in an area of 46m² 
(within 2.5m high), namely 115 m

ᶟ. In order to facilitate the air circulation and the filter 

optimization, please place the device at the entrance of the air (such as controllable ventilation 
equipment, doors and windows).

 

1-  Remove the device from the bag. 
2-  Keep the original packaging throughout the lifespan of the device 
3-  Open the front cover and reach the filter 
4-  Take the filters out of their packaging and put them back.  

The sequence refers to filter replacing sketch

 

5-  Connect the device to a socket.

 

 

If the power is pulled out and reconnected again, the device will return to the initial state, 
and store of the sensor mode will also be cleared.

 

 

 

2.

 OPERATING INSTRUCTIONS 

 

Following  the  installation,  the  air  purifier  is  ready  to  use.  Before  pressing  the  power  button, 
please read the following instructions carefully to ensure the normal operating of the device

  

 
How does this device operate? 

After operating the device, contaminated air is drawn into filtration system from the front part. 
The device starts filtering. Fresh air is released from the top, finally purifying the entire room.  
 
Depending on your needs and the current environment, you can select the appropriate fan speed 
via the control panel or remote control 

(Active  Oxygen  function is only activable with the 

remote control)

 

 
 

A.

  FILTER FUNCTION 

 

This air cleaner device only supports the following types of filters:

 

 

 

1 -

 

Medical HEPA filter (High Efficiency Particulate Air filter)

  It can purify dust particles of 0.0003 mm (0,3 microns) and bacteria 

  It captures fine dust, dust mites, pollen, animal hair, diesel particulates, molds, spores, fungi, 

pesticides, bacteria, viruses and micro-organisms 

 

2

 

– 

Active carbon filter : 

  Captures toxic gases, pesticides, cooking fumes, Tobacco, etc. 

  It can eliminate odors. 

  It absorbs VOC (volatile organic compounds), formaldehyde, benzene, hydrogen sulfide, 

ammonia vapor, 

bleach… 

  It can accelerate the decomposition of ozone in the atmosphere. 

 
 
 
 
 

Summary of Contents for LUX AIR STYLE

Page 1: ...Air Purifier User LUX AIR STYLE Guide Before operating equipment Make sure the filter is removed from the packaging Remove the motor belt and then read the following manual carefully ...

Page 2: ...he device under direct sunlight or near the heat Voltage of the device ranges between 220 to 240 v In order to prevent fire and electric shock do not insert it into sockets with a higher voltage Do not twist or pull the power cord excessively do not place heavy objects on the device To avoid the risk of electric shock do not connect the power cord to damp places Do not place any metal objects insi...

Page 3: ...owing instructions carefully to ensure the normal operating of the device How does this device operate After operating the device contaminated air is drawn into filtration system from the front part The device starts filtering Fresh air is released from the top finally purifying the entire room Depending on your needs and the current environment you can select the appropriate fan speed via the con...

Page 4: ...ons can clean large particles suspended in the air It can make the dust and pollens suspended in the air fall to the ground It can dissipate smog and peculiar smell It can produce 8 million anions per second ACTIVE OXYGEN OR OZONE Active Oxygen function can be used as a deep cleaning process once a week for example after you leave the room Ozone is a very powerful natural cleanser but it can be da...

Page 5: ...the air in order to pleasant and beneficial The quantity of ozone generated is 0 50 ppm per hour according to the standards This function stops automatically after 20 minutes of operation then the purifiers continues to work without the O3 function with previous settings Active Oxygen mode is activable only with the remote control CHILD SAFETY This function will prevent small hands to change the s...

Page 6: ...ery supplied with the remote control The sign should be visible 4 COMMISSIONING Press the POWER button The purifier is activated the screen lights up FUNCTIONS Press the FUNCTION button repeatedly to change the functions of the device Anions UV lamps Anions and UV lamps Active Oxygen function is only activable with the remote control ...

Page 7: ...e icon repeatedly to choose the wanted operation duration wait for 5 seconds to validate your choice To cancel your choice press the TIMING icon for 3 seconds Press the TIMING icon to visualize the duration you have chosen RESET After each filter and or UV lamp change please press the RESET button in order to inform the device that a new accessory has been implemented SMART MODE INTELLIGENT The Lu...

Page 8: ...ward your position 6 Close the front cover align the four sides of the front cover with the machine from bottom to top push it in and close the front cover Make sure that the front cover is correctly closed otherwise the machine will not operate 7 Press the POWER button after reconnecting the power supply 8 Press the RESET button for the replaced filters 6 UV LAMPS REPLACEMENT If the UV indicator ...

Page 9: ... removed and there is noise Change the HEPA filter There is cold wind blowing from the machine The blow of cold wind is normal Cold air is inhaled filtered and blown creating a feeling of freshness 9 PRODUCT SPECIFICATIONS Fan speed Night Low Medium High Airflow m3 h 180 230 320 365 Volume dB A 24 30 37 45 Power watt 39 45 50 54 Negative ions 8 millions second cm3 Dimensions width x height x lengt...

Page 10: ...changes of components The warranty is only suitable for replacing the pieces that is considered broken by our After sales service In case of malfunction of your device please contact NatéoSanté Technical Support P A du Pont Béranger II 44680 Saint Hilaire de Chaléons FRANCE 33 0 285 520 675 sav nateosante fr Environmental Protection According to the Europeen DEEE requirement electronic equipment s...

Page 11: ...oSanté Show room and After sales service PA du Pont Béranger II 44680 Saint Hilaire de Chaléons FRANCE Head office 13 rue Bonne Fontaine 44 680 SAINTE PAZANNE FRANCE Capital of 320 920 SIRET 535 094 148 000 17 Lux Air Style user manual December 2018 edition ...