background image

21 - EOLIS Air Manager 600 600 S 1200 1200 S

ozone (or Active oxygen) = FeAtUre AvAilAble only on the model 600 S And 1200 S

the ozone feature is designed for deep cleaning (once a week, for example).
Ozone is a very powerful natural detergent, and like bleach or chloride, this feature must be used 
with caution. Ozone is effective against embedded odours (even in bedding), dust mites, mould, 

fungus, etc. to activate the OZONE feature, press the ON button. to deactivate it, press the OFF button.
When you press the OZONE icon, you can select which treatment mode to apply to your room:

oFF:

 No ozone treatment.

mode 1:

 Light treatment - small amount of ozone emitted 

regularly (every 10 minutes). the room can be occupied during 
the treatment. Determine the volume of the room to treat (m

3

L x W x h).

mode 2:

 Curative treatment (deep clean) - strong dose of 

ozone emitted at once. the room must be unoccupied for at 
least 1 hour (no humans or animals present).

Sleep mode

Put your unit’s screen in sleep mode after 30 sec, 2 min, 5 min, or 15 min of inactivity. In sleep 
mode, the screen goes dark, and lights back up when you press on it again.

Uv lAmp

to activate the UV LAMP feature, press the ON button. to deactivate it, press the OFF button.  
With the photocatalytic filter, the UV lamps eliminate the VOCs present in glues, varnishes, paints, 
furniture and household cleaning products. these lamps use a 240 nm light wavelength which 

eliminates micro-organisms. 

plAnner

to activate the PLANNER feature, press the ON button. to deactivate it, press the OFF button.  to 
customise the operation of your EOLIS Air Manager for the week, press the PLANNER icon. then 
you can play with it:

this example shows that all thursdays, the unit operates as follows:

 

- From midnight to 6:00 a.m.: Operating in Active mode

 

- From 6:00 a.m. to 3:00 p.m.: Operating in speed 2

 

- From 3:00 p.m. to 8:00 p.m.: Operating in speed 1

 

- From 8:00 p.m. to midnight: Operating in night mode

If the planner is set to ON and no time slot is selected, your air purifier operates in ACtIV mode (default 
mode).

Summary of Contents for EOLIS Series

Page 1: ...e appareil V rifiez que l emballage du bloc de filtres ait bien t retir puis lisez attentive ment ce manuel d utilisation avant la mise en marche de l appareil Nat oSant vous remercie pour votre choix...

Page 2: ......

Page 3: ......

Page 4: ...tir de la pi ce son usage sera inefficace Remettez le en marche lorsque vous aurez ferm vos fen tres EOLIS Air Manager est con u pour tre utilis en habitation dans des bureaux dans des Collectivit s I...

Page 5: ...et la sortie d air S assurer que l entr e et la sortie d air ne soient pas entrav es ou recouvertes Pour viter les risques de chocs lectroniques ne pas exposer le c ble d alimentation au contact de su...

Page 6: ...de filtres compos de un pr filtre antibact rien un filtre charbon actif THD un filtre HEPA H13 ou ULPA U15 de qualit m dicale et un filtre photocatalyse Zoom sur les diff rentes fonctions de ces filt...

Page 7: ...de la qualit de votre air int rieur au cours des 12 derni res heures Param tres Appuyez sur l ic ne param tres pour afficher la liste des r glages et des fonctions disponibles de votre appareil S cur...

Page 8: ...i vous n avez pas de probl matique particu li re allergies probl mes respiratoires entr e soudaine de pollution la vitesse 1 est suffisante pour une purification en continu de nuit comme de jour Param...

Page 9: ...itesse 2 de 15h 20h fonctionne en vitesse 1 de 20h minuit fonctionne en mode nuit Si le planificateur est ON et qu aucun cr neau horaire n est coch votre purificateur d air fonctionnera en mode ACTIV...

Page 10: ...rmalement avec les r glages pr tablis Vous pouvez r int grer la pi ce BIPS SONORES Les BIPS SONORES s activent d s que vous appuyez sur une touche et d s que l mission d ozone d bute Pour activer les...

Page 11: ...filtres sont encrass s hauteur minimale de 80 Selon l tat d usure de vos filtres votre appareil vous avertit de la fa on suivante 80 d usure du filtre Pr voir changement des filtres 100 d usure du fil...

Page 12: ...qui mane de votre appareil L air froid se trouvant au niveau du sol est aspir filtr puis propuls Cela peut engendrer une sensation de fra cheur Le symbole d faut appara t sur l cran principal Une anom...

Page 13: ...onn ou probl me d tanch it du local Si ce message s affiche dans D fauts il se peut qu EOLIS Air Manager soit sous dimensionn par rapport la superficie de votre pi ce V rifiez gale ment qu aucune port...

Page 14: ...utilisation des produits ou une autre que celle qui leur est attribu Les filtres et le module de g n rateur d ozone sont des pi ces d usure Ils ne sont pas pris en charge par la garantie La garantie...

Page 15: ...r unit Make sure that the filter packaging has been removed and carefully read this instruction manual before turning on the unit Nat oSant thanks you for choosing us and we wish you a smooth installa...

Page 16: ...fficient Start it up again when you close the windows EOLIS Air Manager is designed for use in residences offices and communal areas Ideally place your unit across from an air inlet mechanical ventila...

Page 17: ...sure that the air inlet and outlet are not blocked or covered To avoid the risk of electric shock do not allow the power cord to come in contact with damp or wet surfaces Make sure no liquid comes in...

Page 18: ...posed of an anti bacterial pre filter a VHD activated carbon filter a medi cal grade HEPA H13 filter or ULPA U15 and a photocatalytic filter The specific functions of these filters Bactericidal viruci...

Page 19: ...TA LOG icon to display the indoor air quality log for the previous 12 hours Settings Press the SETTINGS icon to display a list of settings and features available in your unit Childproof This safety se...

Page 20: ...ot have a specific problem aller gies breathing problems sudden pollution etc speed 1 is sufficient for continual purification at night time or during the day Settings By pressing the SETTINGS icon yo...

Page 21: ...ns or animals present Sleep mode Put your unit s screen in sleep mode after 30 sec 2 min 5 min or 15 min of inactivity In sleep mode the screen goes dark and lights back up when you press on it again...

Page 22: ...r at least 1 hour the unit begins oper ating normally with the preset settings You can return to the room TONES The TONES are activated as soon as you press on a button and as soon as ozone is emitted...

Page 23: ...ed use status will appear You will receive an alert when your filters are 80 clogged Depending on the use level of your filters your unit will alert you as follows 80 used filter Plan to change filter...

Page 24: ...ng from your unit Cool air from the ground level is drawn up filtered and then propelled out This can make the air feel cool The error symbol appears on the main screen An irregularity has been detect...

Page 25: ...OC levels present in the air Purifier too small or local airtight ness problem If this message appears in Errors your air purifier might be too small for your room s surface area Also make sure that n...

Page 26: ...of the products or a use other than their intended use The filters and ozone generator module are parts that wear over time They are not covered by the warranty The warranty only applies if Nat oSant...

Page 27: ...que el embalaje del bloque de filtros se haya retirado bien Despu s lea atentamente este manual de uso antes de poner en marcha el aparato Nat oSant le agradece su elecci n y le desea una buena insta...

Page 28: ...a a ponerlo en marcha cuando haya cerrado las ventanas EOLIS Air Manager est dise ado para su uso en viviendas oficinas y lugares p blicos Lo ideal es situar el aparato frente a una entrada de aire VM...

Page 29: ...cubiertas Para prevenir los riesgos de choques el ctricos no exponer el cable de alimentaci n al contacto con superficies h medas o mojadas Ning n l quido debe penetrar en la superficie ni el interior...

Page 30: ...com puesto de un prefiltro antibacteriano un filtro de carb n activo THD un filtro HEPA H13 o ULPA U15 de calidad m dica y un filtro fotocatal tico Detalles de las diferentes funciones de estos filtro...

Page 31: ...ver el historial de la calidad de su aire interior a lo largo de las 12 ltimas horas Par metros Pulse el icono par metros para ver la lista de los ajustes y las funciones disponibles de su apara to S...

Page 32: ...problemas espec fi cos alergias problemas respiratorios entrada repentina de poluci n la velocidad 1 es suficiente para una purificaci n continuada tanto de noche como de d a Par metros Al pulsar el...

Page 33: ...elocidad 2 de 15 h a 20 h funciona en velocidad 1 de 20 h a medianoche funciona en modo noche Si el planificador est ON y no se ha indicado ninguna franja horaria EOLIS Air Manager funcionar en modo A...

Page 34: ...a como m nimo el aparato vuelve a funcionar de forma habitual con los ajustes preestablecidos Se puede volver a acceder a la habitaci n BIPS SONOROS Los BIPS SONOROS se activan desde que se pulsa un b...

Page 35: ...os filtros Su aparato le avisa cuando los filtros est n obstruidos en m nimo un 80 Seg n el estado de desgaste de los filtros el aparato le avisa de la siguiente manera 80 de desgaste del filtro Preve...

Page 36: ...o que se encuentra al nivel del suelo es aspirado filtrado y despu s propulsado Esto puede generar una sensaci n de frescor El s mbolo de error aparece en la pantalla principal EOLIS Air manager ha de...

Page 37: ...demasiado peque o o problema de estanqueidad de la sala Si aparece este mensaje en Errores puede que EOLIS Air manager sea demasiado peque o con respecto al tama o de su habitaci n Compruebe que ning...

Page 38: ...de los productos ni otro diferente a aquel para el que est destinado Los filtros y el m dulo de generador de ozono son piezas de desgaste No se toman en cuenta para la garan t a La garant a solo se ap...

Page 39: ...dass die Verpackung des Filterblocks entfernt wurde und lesen Sie diese Gebrauchsanleitung vor Inbetriebnahme des Ger ts aufmerksam durch Nat oSant dankt Ihnen f r diesen Kauf und w nscht Ihnen eine e...

Page 40: ...n Sie es ein wenn die Fenster wieder haupts chlich geschlossen sind EOLIS Air Manager wurde f r den Gebrauch in Wohnh usern B ros K rperschaften entwickelt Stellen Sie das Ger t idealerweise gegen ber...

Page 41: ...dass Lufteintritts und austritts ffnung nicht verstopft oder abgedeckt sind Zur Vermeidung von Stromschl gen das Stromka bel nicht mit feuchten oder nassen Oberfl chen in Ber hrung bringen Zur Vermei...

Page 42: ...den fol genden Elementen zusammen ein antibakterieller Vorfilter ein THD Aktivkohlefilter ein HEPA Filter H13 oder ULPA U15 medizinischer Qualit t und ein Fotokatalyse Filter Zoom auf die verschiedene...

Page 43: ...STORIE um den Verlaufsbericht Ihrer Raumluftqualit t f r die vergangenen 12 Stunden zu sehen Parameter Dr cken Sie auf das Symbol Parameter um die Liste der Einstellung und der verf gbaren Funk tionen...

Page 44: ...e besonderen Probleme haben Allergien Atembeschwerden pl tzliches Eintreten einer Verschmutzung reicht Stufe 1 f r eine kontinuierliche Reinigung tags ber und nachts Parameter Dr cken Sie das Symbol P...

Page 45: ...mindestens 1 Stunde weder Menschen noch Tiere aufhalten Standby Schalten Sie das Display Ihres Ger ts nach 30 s 2 min 5 min oder 15 min Inaktivit t in Standby In diesem Fall wird das Display dunkel S...

Page 46: ...ieb und bernimmt die zuvor eingestellten Parameter Sie k nnen wieder in den Raum gehen PIEPT NE Die PIEPT NE werden aktiviert sobald Sie auf einen Taster dr cken oder sobald die Ozon Frei setzung begi...

Page 47: ...eichzeitig eine Meldung mit dem Verschmut zungsgrad der Filter angezeigt Die Warnmeldungen des Ger ts setzen ab einem Filterverschlei von 80 ein Je nach Verschlei der Filter warnt das Ger t wie folgt...

Page 48: ...stritt Die in Bodenn he k hlere Luft wird angesaugt gefiltert und ausgesto en Dadurch kann ein Eindruck von K hle entstehen Auf dem Hauptbildschirm erscheint das Fehler Symbol EOLIS Air Manager hat ei...

Page 49: ...in der Luft vor Reiniger zu gering dimensioniert oder Dichtigkeitsproblem des Raums Wenn diese Meldung unter Fehler erscheint kann es sein dass EOLIS Air Manager f r das Volumen Ihres Raums zu klein i...

Page 50: ...llen nicht in den Gew hrleistungsumfang der Garantie Die Garantie gilt nur wenn es sich bei den verwendeten Filtern um Filter mit Zertifizierung durch Nat oSant handelt Die Garantie gilt nicht f r Feh...

Page 51: ......

Page 52: ...l de 254 060 SIRET 535 094 148 000 33 Manuel d utilisation EOLIS Air Manager 600 1200 600 S 1200 S ditionjuin 2016 Certifi PEFC Ce produit est issu de for ts g r es durablement et de sources contr l e...

Reviews: