COMMUNICATION

Communication between the SPEAKER SWITCHING UNIT (SSU), the
TALKING DISPLAY UNIT (TDU) and the MULTIPLE INPUT UNIT (MIU) is
achieved via a standard 6 wire telephone cable.

A short 6 wire telephone cable is supplied with the SSU and the MIU.

This can be substituted if necessary with any 6 wire cable with a length
up to 100m.

POWER

Power for the SSU and the MIU is supplied from the TALKING DISPLAY
UNIT (TDU) via the same 6 wire cable.

INSTALLATION PROCEDURE

1) Using a 6 wire telephone cable, connect Communications Port 1 of
the SPEAKER SWITCHING UNIT (SSU) to the Sensor Input port of the
TALKING DISPLAY UNIT (TDU).

2) Using another 6 wire telephone cable, connect  Communications Port
2 of the SPEAKER SWITCHING UNIT (SSU) to the Communications
Port of the MULTIPLE INPUT UNIT (MIU).

3) Connect a separate 12VAC or 12VDC (minimum of 300mA - polarity
independent) power source to the power adaptor jack of the MULTIPLE
INPUT UNIT (MIU).

This additional power input for the MIU is required to prevent the
possibility of ‘brown out’ when the SPEAKER SWITCHING UNIT and
MULTIPLE INPUT UNIT are used in the same application.

4) Solder the connections for your Speakers to the supplied Male DB25
connector, as per the table on page 6.

A separate male DB25 connector, with exposed terminals is supplied
with this unit to allow direct solder connection of cables leading to each
speaker.

Summary of Contents for Speaker Switching Unit

Page 1: ...Speaker Switching Unit User Guide For Technical Assistance Please Phone 07 5596 5128 ...

Page 2: ...speaker 1 Sensor 2 when triggered will cause Message 2 to play on speaker 2 Sensor 3 when triggered will cause Message 3 to play on speaker 3 Sensor 4 when triggered will cause Message 4 to play on speaker 4 Sensor 5 when triggered will cause Message 5 to play on speaker 5 Sensor 6 when triggered will cause Message 6 to play on speaker 6 Sensor 7 when triggered will cause Message 7 to play on spea...

Page 3: ...2 5 watts Alternatively powered speakers or an external amplifier can be used for greater volume output Power for the SSU and communication between the SSU and the TDU is achieved via a supplied 6 wire telephone cable which connects to an RJ11 format 6 position communications port The SSU has 2 identical communications ports that provide for power and communication between the SSU the TDU and othe...

Page 4: ...SU to the Sensor Input port of the TALKING DISPLAY UNIT TDU 2 Using another 6 wire telephone cable connect Communications Port 2 of the SPEAKER SWITCHING UNIT SSU to the Communications Port of the MULTIPLE INPUT UNIT MIU 3 Connect a separate 12VAC or 12VDC minimum of 300mA polarity independent power source to the power adaptor jack of the MULTIPLE INPUT UNIT MIU This additional power input for the...

Page 5: ...cted that will be supplied to all speakers at all times This primary audio feed will then be replaced by the TDU message only on the appropriate speaker whenever the TDU is triggered The primary audio feed is then reconnected at the end of the TDU message The primary audio feed connects to the AUDIO INPUT 2 port 8 Install the TALKING DISPLAY UNIT TDU and the MULTIPLE INPUT UNIT MIU as per the sepa...

Page 6: ... p S 7 1 n i P 9 r e k a e p S 6 n i P 8 r e k a e p S 8 1 n i P 8 r e k a e p S 7 n i P 7 r e k a e p S 9 1 n i P 7 r e k a e p S 8 n i P 6 r e k a e p S 0 2 n i P 6 r e k a e p S 9 n i P 5 r e k a e p S 1 2 n i P 5 r e k a e p S 0 1 n i P 4 r e k a e p S 2 2 n i P 4 r e k a e p S 1 1 n i P 3 r e k a e p S 3 2 n i P 3 r e k a e p S 2 1 n i P 2 r e k a e p S 4 2 n i P 2 r e k a e p S 3 1 n i P 1 r...

Page 7: ...National Communications Page 7 NOTES ...

Page 8: ...d a written statement about the nature of the problem The obligation is solely to repair or replace the product The warrantor is not liable for any incidental or consequential damages due to such defects This Warranty shall not apply to any unit which has been subject to alteration modification abuse negligence accident external voltage lightning surge or used in any manner contrary to these instr...

Reviews: