16
Parameter
Default
Description
M
PP
T
Co
n
stan
t
val
u
e
Fi
x sp
e
e
d
Co
n
st.v
al
u
e
2
set
Fi
x sp
e
e
d
2
val
.
Exte
rn
al
sp
e
e
d
50
Frequency value to feed the pump.
50
Minimum frequency below which the
pump tries to stop.
5
Delay for which the pump tries to
stop below freq.min.control.
20
Ramp time from freq.min.control to
min.motor freq. If, during this time,
the read value goes below the (set
value - delta control), the inverter
powers the motor again; otherwise,
the inverter will stop the pump.
0.1
Value drop below the set value
required to restart the pump during
control ramp.
0.5
Value drop below the set value
required to start the pump from stop
condition.
0.5
Value increase respect to set value
which must be passed so that there is
a forced shutdown of the pump.
XX
MPPT voltage gap.
XX
MPPT time gap.
sec
Hz
Freq.min.control
press.
Set value
Min mot. freq
Stop delay
Control ramp
Delta control
Operating freq. 2
XXX [Hz]
Freq.min.control
XXX [Hz]
Stop delay
XX [s]
Control ramp
XXX.X [s]
Delta control
XXX.X [bar]
Delta start
XXX.X [bar]
Delta stop
XXX.X [bar]
MPPT: volt. gap
dV = XX.X [V]
MPPT: time gap
dt = XX.X [s]