Nash Elmo G 400 Series Operating Instructions Manual Download Page 5

 
 

 

 

 

nash_elmo Industries GmbH 

5 / 23 

 

Order No.: 610.44436.40.000 

Subject to change 

 

 

Edition 09/2003 

 

Safety

 

  WARNING 

Danger from rotating impeller: 
Cutting/cutting off of extremities! 

The rotating impeller is accessible with the inlet 
and discharge connections open! 
Do not reach into the unit through open 
connections! 
Do not insert objects into the unit through the 
openings! 

 

 

  WARNING 

Danger from rotating impeller: 
Cutting/cutting off of extremities! 

The rotating impeller is accessible with the inlet 
and discharge connections open! 
With free entry and exit of gases, i.e. with 
direct intake out of or direct feeding into the 
atmosphere without piping, the following 
therefore applies: 
Provide the inlet and discharge connections of 
the pump-motor unit either with additional 
mufflers or with additional piping of a sufficient 
length to prevent access to the impeller! 

 

 

  WARNING 

Danger of burns from hot surfaces of the 
pump-motor unit and from hot fluids! 

High temperatures of up to approx. 160 °C 
[320 °F] can occur on the surface of the pump-
motor unit. 
Cover the pump-motor unit with a suitable 
touch protection (e.g. perforated plate cover or 
wire cover). 
Do not touch during operation! 
Allow to cool after shut-down! 

 

1.3 Residual 

risks 

 

  WARNING 

Danger zone: 

Hot surface up to approx. 160 °C [320 °F]. 

Hazard: 

Possible burns. 

Protective measures: 

Cover the pump-motor unit with a suitable 
touch protection (e.g. perforated plate cover or 
wire cover). 

 

 

  WARNING 

Danger zone: 

Fan guard 

Hazard: 

Long, loose hair can be drawn into external fan 
through fan guard grate, even with fan guard 
mounted! 

Protective measures: 

Wear hair net! 

 

 

  WARNING 

Danger zone: 

Missing or defective muffler inlet or discharge 
connection. 

Hazard: 

Possible serious hearing damage due to 
emitted noise. 

Protective measures: 

Have missing or defective mufflers replaced. 
Conduct a noise measurement in the system 
after installing the pump-motor unit.  
The following measures must be taken by the 
operator: 

• 

from 85 dB(A): 

– 

Hearing protection must be provided. 

• 

from 90 dB(A): 

– 

Mark noise area with a warning sign. 

– 

Wear hearing protection. 

 

 

  WARNING 

Danger zone: 

Environment of pump-motor unit. 

Hazard: 

Possible serious hearing damage due to 
emitted noise. 

Protective measures: 

Conduct a noise measurement in the system 
during operation after installing the pump-
motor unit. 
The following measures must be taken by the 
operator: 

• 

from 85 dB(A): 

– 

Hearing protection must be provided. 

• 

from 90 dB(A): 

– 

Mark noise area with a warning sign. 

– 

Wear hearing protection. 

– 

With free entry and exit of gases, i.e. 
with direct intake out of or direct feeding 
into the atmosphere without piping, 
attach an additional muffler. 

 
 

Summary of Contents for G 400 Series

Page 1: ...n 09 2003 English Phone 49 911 1454 5268 Fax 49 911 1454 5252 E mail service nash elmo com Internet www nash elmo com Gas Ring Vacuum Pumps Compressors Operating Instructions Series G_400 Models 2BH7...

Page 2: ...llation 12 5 2 Electrical connection motor 14 5 3 Connecting pipes hoses vacuum pump compressor 16 5 3 1 Inlet connection 17 5 3 2 Discharge connection 17 5 3 3 Procedure when connecting pipes hoses 1...

Page 3: ...ld result in death or serious injury if the corresponding measures are not taken CAUTION Danger of injuries Indicates a potentially hazardous situation that may result in minor or moderate injury if t...

Page 4: ...ng parts external fan impeller shaft Cutting cutting off of extremities Grasping winding up of hair and clothing Danger due to vacuum and gauge pressure sudden escape of fluids skin and eye injuries s...

Page 5: ...Residual risks WARNING Danger zone Hot surface up to approx 160 C 320 F Hazard Possible burns Protective measures Cover the pump motor unit with a suitable touch protection e g perforated plate cover...

Page 6: ...t in the following designs single impeller single stage two impeller two stage three impeller three stage Increased pressure differences can be achieved with the two impeller and three impeller pump m...

Page 7: ...H75 approx 52 approx 2 05 2BH76 approx 53 approx 2 09 Minimum distance to vacuum pump compressor cover Minimum distance to face of vacuum pump compressor cover mm inches 30 1 18 Vibrations The followi...

Page 8: ...approx 142 2BH7310 0 2 approx 86 approx 187 2BH7410 0 1 approx 101 approx 214 2BH7510 0 1 approx 111 approx 232 2BH7510 0 2 approx 112 approx 234 2BH7610 0 1 approx 124 approx 255 2BH7610 0 3 approx...

Page 9: ...3 4 2 21 2 95 M20x1 5 4 5 2 95 3 69 M32x1 5 M40x1 5 5 7 3 69 5 16 3 2 Electrical data See rating plate 3 3 Operating conditions Temperatures max permissible temperature 40 C 104 F Nominal value 15 C...

Page 10: ...oes and protective helmet during transport WARNING Danger from tipping or falling loads Prior to transport and handling make sure that all components are securely assembled and secure or remove all co...

Page 11: ...lectrical device cannot be damaged by external influences In particular the feed pipes must be securely routed e g in cable ducts in the floor etc WARNING Danger from balance damage caused by vibratio...

Page 12: ...differs from the following specifications it is necessary to inquire with the Service Department Ambient conditions The pump motor unit is suitable for installation in the following environments In a...

Page 13: ...the pump motor unit the following variants are possible with a different axis position horizontal or vertical Horizontal installation Vertical installation on the vacuum pump compressor cover cover in...

Page 14: ...und and short circuit Cover or block off adjacent energized parts CAUTION Incorrect connection of the motor can lead to serious damage to the unit Regulations The electrical connection must be carried...

Page 15: ...protective conductor the outer ground conductor Both conductors can be recognized from their color green yellow DANGER Electrical danger The terminal box must be free from foreign bodies dirt humidit...

Page 16: ...d reasons and must be mounted by the operator Fig 3 2BH722 2BH762 two impeller pump motor units with two stage design Fig 4 2BH723 2BH763 three impeller pump motor units with three stage design WARNIN...

Page 17: ...the related muffler Fig 1 Pg 2 Item 3 is marked with an arrow pointing into the vacuum pump compressor Connect the inlet pipe here The pumped gases are sucked in via this Procedure see Chapter 5 3 3 W...

Page 18: ...again after a longer standstill Measure the insulation resistance of the motor With values 1 k per volt of nominal voltage the winding must be dried Measures before start up If a shut off device is in...

Page 19: ...piping attach an additional muffler 6 2 Start up and shut down Start up Open shut off device in intake discharge pipe Switch on power supply for drive motor Shut down Switch off power supply for drive...

Page 20: ...nt must provide the following conditions dry dust free low vibration effective value of vibration speed veff 2 8 mm s 0 11 sec Ambient temperature max 40 C 104 F CAUTION Danger of overheating due to h...

Page 21: ...ck or correct impeller gap setting if necessary Service Impeller defective Replace impeller Service Motor does not start humming noise Rolling bearing on drive motor side or vacuum pump compressor sid...

Page 22: ...e procedure described in Chapter 9 3 Decontamination and Declaration of Clearance Pg 22 must be used The original rating plate of the pump motor unit must be properly mounted intact and legible All wa...

Page 23: ...ery Part 1 Principles and specifications for machinery manufacturers DIN EN 1012 1 Compressors and vacuum pumps Safety requirements Part 1 Compressors DIN EN 1012 2 Compressors and vacuum pumps Safety...

Reviews: