background image

Now attach the subclavian 

and internal jugular veins 

from the shoulder to the top 

of the “Y” connector. After 

attaching the subclavian and 

the internal jugular to the “Y” 

connector, apply the strap-

ping ties to ensure a tight seal 

of the tubing to the connector. 

Attach the fluid bag with the 

open tube to the bottom of 

the “Y” connector. These ties 

will remain in position until the 

tubing is changed. To remove 

them, simply cut them off. 

(See figure 10.)

The external jugular vein is 

set up with its own fluid bag. 

Connect the fluid bag with 

the straight connector to the 

external jugular vein. Do not 

use strapping ties to perma-

nently attach the vein to the 

connector, as it will be dis-

connected after each use for 

easier installation later. 

(See 

figure 11.)

Mix the blood solution 

according to the instructions 

on the bottle. Close the slide 

clamps on both fluid bags. 

Pour contents into the bag, 

seal the top of the fluid bag, 

and hang on an IV stand. 

(sold separately.) The bottom 

of the fluid bag should not be 

more than 12" to 14" above 

the simulator. 

(See figure 

11.)

8

Figure 10

Figure 11

NP155_86_LF01087_CentVenoCannulation.indd   8

9/14/15   9:03 AM

Summary of Contents for Lifeform LF01087U

Page 1: ...Central Venous Cannulation Simulator LF01087U Instruction Manual Products by Nasco WARNING Products may contain dry natural rubber NP155_86_LF01087_CentVenoCannulation indd 1 9 14 15 9 02 AM ...

Page 2: ...NP155_86_LF01087_CentVenoCannulation indd 2 9 14 15 9 02 AM ...

Page 3: ...ct medical personnel in the practice of central venous cannulation The sim ulator incorporates superficial anatomical detail and functional accuracy to simulate the clinical experience List of Components A Torso Base B Muscle Bone Insert C Skin Overlay D 2 Fluid Bags 1 500 ml E 22 gauge Needle F Baby Powder G 1 qt Life form Venous Blood H 6 Subclavian Tubes 20 I 6 Internal Jugular Veins 20 J 6 Ext...

Page 4: ...lation Simulator offers other features that extend the application of this instructional aid to include demonstration of anatomical landmarks for 1 Pericardiocentesis 2 Thoracentesis D Replicate Bilateral Carotid Pulse Manual Preparing the Simulator for Use Inspect the contents to be certain all necessary components are includ ed see List of Components Generously powder the torso base of the simul...

Page 5: ...end at the lower edge Run the vein along the outside edge and through the hole to the front side of the muscle bone insert Continue following the vein channel on the front side See figure 5 Next position the internal jugular vein tubing letter I in the list of components This tube is short and small in diameter Insert tubing over the top of the subclavian vein tubing keeping the knot inside the mu...

Page 6: ...ugh the hole in the jaw of the torso base See figure 6 Position the carotid pulse tubing into the channel on the outside of the muscle bone insert See figure 7 Applying tape not included to the carotid pulse tubing will help hold the tubing in place on the torso base See figure 7 insert Figure 6 Figure 7 Figure 7 insert NP155_86_LF01087_CentVenoCannulation indd 6 9 14 15 9 02 AM ...

Page 7: ... overlay Disconnect the pulse bulb on the carotid pulse tubing Pull the ends of all three tubes through the open ing in the skin located on the simulator s left shoulder See figure 8 Be sure all tubing is still in the channels and reconnect the pulse bulb See figure 9 Figure 8 Figure 9 NP155_86_LF01087_CentVenoCannulation indd 7 9 14 15 9 02 AM ...

Page 8: ... vein is set up with its own fluid bag Connect the fluid bag with the straight connector to the external jugular vein Do not use strapping ties to perma nently attach the vein to the connector as it will be dis connected after each use for easier installation later See figure 11 Mix the blood solution according to the instructions on the bottle Close the slide clamps on both fluid bags Pour conten...

Page 9: ...into the tubing of the subclavian very close to the knot See figure 12 Open the slide clamps on the fluid bag When the air is released completely simulated blood will flow from the top of the needle See figure 13 Remove the needle at this point and repeat the procedure at the knotted end of the internal jugular Replace the skin See figure 13 inset 9 Figure 12 Figure 13 Figure 13 insert NP155_86_LF...

Page 10: ...nty 2 DO NOT allow any newsprint or plastic to come into contact with the simulator Ink of any type will cause indelible stains 3 DO NOT mark on the simulator in any way 4 Solvents or corrosive materials will damage the simulator 5 Maintain the slide clamps in the open position when simulator is not in use to prevent kinking in the tubing Supplies Replacement Parts LF00845U Quart of Life form Veno...

Page 11: ...NP155_86_LF01087_CentVenoCannulation indd 11 9 14 15 9 03 AM ...

Page 12: ...ment Trainer with Stand LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin LF03620U PALS Update Kit LF03623U Infant Airway Management Trainer with Stand LF03632U Child Intraosseous Infusion Femoral Access Leg on a Stand LF03633U Child Airway Management Trainer Torso LF03693U Basic Buddy CPR Manikin LF03699U Airway Larry AIrway Management Trainer LF03709U Infant CRiSis Manikin LF037...

Reviews: