SET UP

1.

Place the pelvic organ block into the torso as pictured, making sure it is locked in place beneath the 

pubic bone. 

(See figure 1.)

 

Note:

 See Special Features section related to use of the bladder before moving forward.

2.

Select a uterus/cervix piece and attach the ovaries as shown. 

(See figure 2.)

 Ovaries may be used in 

any combination with uterus/cervix pieces except letter (D) IUD. 

Note: 

The permanent tubing extending from the normal uterus (A) can exit the lower torso in any 

position convenient for procedure. See Discharge Option in the Special Features section for addi-

tional information.

Figure 2

Figure 1

SPECIAL FEATURES:

1.

Patent Urethra: The patent urethra will accept a Foley catheter (16 FR or smaller). The catheter may 

be inflated, although the bladder is not designed to hold fluid.

2.

Bladder: The bladder insert may be used to simulate a full bladder. Insert the bladder into the Pelvic 

Organ Block as desired for training scenarios during the initial steps of set up. 

(See figure 9.)

3.

Prolapse: The double-ended pelvic organ prolapse insert may be positioned anywhere within the 

vagina. Be sure to lubricate the insert before placement. 

(See figures 10 and 11.)

4.

Discharge Option: The normal uterus (A) has an optional discharge function. In a small cup, mix a 

small amount of thickener and/or blood powder with water to get the desired color and consistency. 

(Use caution — blood will stain fabric and skin.) Fill the syringe and inject the mixture through the 

tubing until it comes out the cervix. 

(See figure 12.) 

Rinse and dry all parts thoroughly before storage.

3.

Insert the uterus/cervix into the cavity in the pelvic organ block. 

(See figure 3.)

4.

Fasten the genital pad onto the torso. Fold the top edge over the pubic bone then attach as shown. 

(See figures 4 & 5.)

5. 

Place the gel pad into the abdominal cavity The pad should cover the ovaries, but not the uterus. 

(See figure 6.)

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11

6. 

lace the abdominal pad on top of the gel pad.

 (See figure 7.)

7.

Attach the abdominal skin to the sides of the torso. 

(See figure 8.)

8.

Remember to ALWAYS thoroughly lubricate anything that will be put into the introitus or vaginal 

vault. Failure to do so will damage the simulator and void your warranty. Nasco recommends a 

waterbased lubricating jelly.

Figure 12

Figure 5

Figure 6

Figure 3

Figure 4

HC18000028INM38.indd   7-8

10/24/18   1:51 PM

Summary of Contents for Life/form LF01235U

Page 1: ...HEALTHCARE AdvancedPelvic Examination GynecologicalSimulator LF01235U INSTRUCTION MANUAL 5 Year Warranty ...

Page 2: ... of uterus and ovaries rectal exam speculum exam Pap test HPV test cytology sampling and fetal fibronectin test and evaluation A B D G C E I H J F K M N L O P TIPS A 1 A 2 A 3 A o 4 M th m ti so o 5 O u co co p to SUPPL LF012 LF012 LF012 LF012 LF012 LF012 LF012 LF012 LF037 LF009 LF099 LF007 LF007 LF012 LF012 LF012 LF012 Actual supplie ...

Page 3: ...es E Fibroids Polyp F Early Pregnancy G D Ovary Set 5 Normal 2 Small Cyst Polycystic Large Adnexal Mass E Prolapse Bladder Inserts 2 F Genital Pad G Gel Pad H Abdominal Pad I Abdominal Skin J Thickener K Blood Powder L Syringe M Primary Colors Makeup Wheel N Injury Shades Makeup Wheel O Baby Powder P Lubricant Q Hard Carry Case not shown be ied ell rans e lible ys ...

Page 4: ...t tubing extending from the normal uterus A can exit the lower torso in any position convenient for procedure See Discharge Option in the Special Features section for addi tional information Figure2 Figure1 SPECI 1 P b 2 B O 3 P va 4 D sm U tu 3 Insert the uterus cervix into the cavity in the pelvic organ block See figure 3 4 Fasten the genital pad onto the torso Fold the top edge over the pubic b...

Page 5: ... Option The normal uterus A has an optional discharge function In a small cup mix a small amount of thickener and or blood powder with water to get the desired color and consistency Use caution blood will stain fabric and skin Fill the syringe and inject the mixture through the tubing until it comes out the cervix See figure 12 Rinse and dry all parts thoroughly before storage own us Figure7 Figur...

Page 6: ... torso and packed separately if the simulator will be trans ported or stored for a prolonged period of time CAUTIONS 1 Use a small medium vaginal speculum The unopened speculum should fit comfortably into the introitus Using equipment that is too large will damage the simulator voiding your warranty Lubricate before each use 2 Never insert anything sharp including fingernails into the simulator 3 ...

Page 7: ...ottage cheese yogurt gelatin or baby food may also be used to simulate common conditions and diseases of the female reproductive tract Check products containing dyes on an inconspicuous area of the torso to test for staining Always disassemble the components afterward and wash thoroughly with warm soapy water especially if using perishable products Rinse well and dry before storage Nasco cannot be...

Page 8: ...ESS 901 Janesville Ave Fort Atkinson WI 53538 HEALTHCARE G Other Available Simulators LF00977U LF01068U LF00977U Single Breast Examination Simulator LF00980U Advanced Breast Exam Simulator LF01068U Cervical Dilatation and Effacement Simulators LF01230U Cervical Exam and Pap Smear Test Trainer LF01230U LF00980U ...

Reviews: