SET UP PROCEDURE FOR ARTERIAL BLEEDING 

Note:

 Before filling the arterial system with synthetic blood, we highly recommend that you 

familiarize yourself with the simulator and the bulb pressure required to operate it using only 

plain, distilled water. Only slight pressure is necessary when pumping blood to the arterial 

wound sites.

Artificial blood will stain, so care should be taken with clothes and surfaces.

A. Prepare Artificial Blood 

Fill the provided artificial blood container with distilled water. 

Tightly replace cap and gently shake bottle until blood powder is 

dissolved. 

1

2

3

B. Fill Arterial System 

Pour 4 oz. of artificial blood into the lower portion of the tray. Taking the squeeze bulb assem-

bly, connect the white color-coded luer lock connector to the fitting on the tray’s corner 

(1)

Twist gently to secure. 

C. Connect to Training Arm 

The artery tubing of the first aid arm is color-coded green. Attach the blue end of the squeeze 

bulb assembly to the green connector of the artery tubing 

(2)

. Gently pumping the squeeze 

bulb will provide blood flow to the arterial system. Adjusting the flow control clamps on the 

artery tubing

 (3)

 will allow or stop blood flow at either site on the arm.

4

SET UP PROCEDURE FOR ARTERIAL BLEEDING 

Note:

 Before filling the arterial system with synthetic blood, we highly recommend that you 

familiarize yourself with the simulator and the bulb pressure required to operate it using only 

plain, distilled water. Only slight pressure is necessary when pumping blood to the arterial 

wound sites.

Artificial blood will stain, so care should be taken with clothes and surfaces.

A. Prepare Artificial Blood 

Fill the provided artificial blood container with distilled water. 

Tightly replace cap and gently shake bottle until blood powder is 

dissolved. 

1

2

3

B. Fill Arterial System 

Pour 4 oz. of artificial blood into the lower portion of the tray. Taking the squeeze bulb assem-

bly, connect the white color-coded luer lock connector to the fitting on the tray’s corner 

(1)

Twist gently to secure. 

C. Connect to Training Arm 

The artery tubing of the first aid arm is color-coded green. Attach the blue end of the squeeze 

bulb assembly to the green connector of the artery tubing 

(2)

. Gently pumping the squeeze 

bulb will provide blood flow to the arterial system. Adjusting the flow control clamps on the 

artery tubing

 (3)

 will allow or stop blood flow at either site on the arm.

HC18000028INM36.indd   7-8

10/16/18   11:32 AM

Summary of Contents for Life/form LF01005U

Page 1: ...HEALTHCARE FirstAidArm LF01005U INSTRUCTION MANUAL 5 Year Warranty ...

Page 2: ......

Page 3: ...ng artery can be per formed with realistic results With proper care your Life form First Aid Arm will provide years of reliable service Please read the instructions carefully B A D E F H C 3 LIST OF COMPONENTS A First Aid Arm with Arm Wound and Severed Thumb B Artificial Blood Powder Quart Bottle C Fluid Supply Bag with Yellow Color Coding and Luer Lock Connector D Recovery Line Tubing with Red Co...

Page 4: ...d water Tightly replace cap and gently shake bottle until blood powder is dissolved 1 2 3 B Fill Arterial System Pour 4 oz of artificial blood into the lower portion of the tray Taking the squeeze bulb assem bly connect the white color coded luer lock connector to the fitting on the tray s corner 1 Twist gently to secure C Connect to Training Arm The artery tubing of the first aid arm is color cod...

Page 5: ...n Place blue connector over a collection container and continue to squeeze bulb until all the artificial blood has been removed from the tray See figure 1 SET UP PROCEDURE FOR VENOUS BLEEDING A Set Up Fluid Supply Bag Close the pinch clamp on the fluid supply bag before filling with artificial blood See figure 2 Venous pressure is altered by varying the height of the supply bag A height of 18 is s...

Page 6: ...vel E Open the pinch clamp on the fluid supply bag F and allow blood to pass through the system D Fluid Flow from Wound Site As fluid flows from the wound site and collects in the tray squeeze the bulb to pump blood back into the fluid supply bag for a continuous flow through the system E Ready for Use The squeeze bulb must be pumped continuously in order to recover the artificial blood back into ...

Page 7: ...urface of the arm as well as the tray with mild liquid detergent and water Ensure all pinch clamps on tubing are open before storing This will prevent kinks and damage to the tubing Stubborn stains may be removed using Nasco Cleaner LF09919U sold separately Simply dispense the Nasco Cleaner to the stained area and wipe clean with a soft cloth Return all components clean and dry to case for storage...

Page 8: ...ailable Simulators LF01095U LF00795U Burn Simulation Kit LF01095U Blood Pressure Simulator LF03000U CPARLENE Series LF03595U Full Body Airway Larry with Electronic Monitoring Memory and Printer Unit LF03596U Full Body Airway Larry with Light Controller LF03740U Universal AED Trainer LF03746U Compression Only BASIC BUDDY 5 Pack LF03750U Bariatric CPR Manikin LF00795U LF03740U ...

Reviews: