CLEANING THE MANIKIN 

Note: Do not autoclave. Excessive heat will destroy the plastic.  

Use Health Department protocols for disinfecting. Use any water 

soluble cleaning agent to clean the surface of any grime or dirt. 

Store the manikin dry in temperatures considered comfortable for 

humans. Excessive heat from storing in locations such as the trunk of 

your car will likely result in deformation of the head. Storing in cold 

temperatures may result in cracking the plastic. If it gets cold, handle 

it gently until the plastic warms up to comfortable room temperatures. 

If the head deforms from pressure associated with storing in a warm 

environment, remove the head from the manikin and immerse it in a 

pot of steaming water for about 20 seconds. The hot water will allow 

the head to spring back to its original shape. Set the head on a flat 

surface and allow to cool in its molded shape. Then install it back on 

the body.

WARRANTY

NASCO HEALTHCARE warrants their products to be free from defects 

in materials and/or workmanship for a period of three years from 

the date of purchase, as evidenced by the date on the invoice of 

the product shipment to the end user. The warranty expressly does 

not cover abuse, accidental or purposeful damage, or any form of 

modification to the product. NASCO HEALTHCARE reserves the right to 

either replace affected parts or the entire unit, at their sole discretion, 

after investigating and reviewing the actual product and the damage.

In most instances, a digital photo of the product in question showing 

the damage will help qualify a product for return to the factory. At no 

time will any product be accepted at the factory without proper return 

authorization issued by NASCO HEALTHCARE.

Freight and shipping charges are the sole responsibility of the end user. 

No product will be received with shipping charges due. Any product 

considered for warranty work must be identified by serial number and

invoice number from the agency through whom the product was 

purchased. Without this information the product will not receive a 

return authorization number as required. 

RETURN POLICY

Should it be necessary to return an item for credit or for any other 

reason, contact our Customer Care Department to obtain an RGA 

Number. Please refer to your invoice number when phoning in your 

request Customer Care Department.

Summary of Contents for Kim

Page 1: ...N MANUAL HEALTHCARE PediatricCPRManikins Kim 100 2901 100 2901B Kevin 100 2976 100 29768B Kyle 100 2951 100 2951B INSTRUCTIONS FOR USE These basic CPR manikins are intended to be used to instruct individuals in the proper procedures and techniques in applying CPR to children of like physical size 1 21 19 3 ...

Page 2: ... sterilized mouth piece at the beginning of class to use through the day s work At the end of the day the face pieces should be decontaminated by using your local Health Department protocols for disinfecting Note Do not autoclave Excessive heat will destroy the plastic Clean with any water soluble cleaning substance The airway lung system is a single piece unit with a one way valve incorporated to...

Page 3: ...rlay skin 1 2 In S Actual product may vary slightly from photo Nasco reserves the right to change product color materials supplies or function as needed HC190001INM13 indd 3 4 3 Turn the baby onto its stomach and pull the knob at the back of the neck away from the baby NOTE It is not necessary to unscrew the head rod 4 Lift the head out of the neck slot 5 Twist and pull the blue retainer off from ...

Page 4: ...ck away from the baby NOTE It is not necessary to unscrew the head rod 4 Lift the head out of the neck slot 5 Twist and pull the blue retainer off from the front of the face depression 6 Pull the one way valve out of the face depression 7 Pull the lung out of the head 5 6 Insert the new lung system Steps 1 Insert the new airway lung system one way valve over the back side of the neck rod and into ...

Page 5: ...e distance for the size of the child P clear the airway ece riate location dy the appropriate child essive heat will destroy the plastic Use Health Department any water soluble cleaning agent to clean the surface of any grime mperatures considered comfortable for humans Excessive heat from nk of your car will likely result in deformation of the head Storing in cold ng the plastic If it gets cold h...

Page 6: ...od of three years from the date of purchase as evidenced by the date on the invoice of the product shipment to the end user The warranty expressly does not cover abuse accidental or purposeful damage or any form of modification to the product NASCO HEALTHCARE reserves the right to either replace affected parts or the entire unit at their sole discretion after investigating and reviewing the actual...

Reviews: