14
RETURNING TO NORMAL OPERATING MODE
Press the
ILLUM
button to return the unit to normal
measurements of speed in the mode which has been set up. All
the settings are stored, and will return again whenever the unit is
switched on. Returning to configuration setting from normal
operation is not available. if further configuration changes are
desired, they can be made onyl by swithcing the unit off and then
on again with
ILLUM
pressed during the start-up time, as
described above.
Get into configuration mode, and press
TRIP.
Suppose the
calibration factor is already set to the factory preset value of 100.
To reduce it by 5, press the
SPEED
Button 5 times to reduce the
unit`s calibration factor to 95 (which is 5 less than the original
calibration factor of 100). Likewise, if the calibration factor has
previously been adjusted to be 104, pressing the
SPEED
button
five times will reduce the factor to 99 to make a 5% reduction in the
calibration factor.
Press
TRIP
to store the new calibration factor, and return the unit to
the “SET” configuration mode. Note that the new calibration factor
applies ony to new measurements. It does not apply
retrospectively to any measurements already made and stored in
the trip and distance stores.