background image

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi/en

4

GB

Narvi Steam Master 

Introduction

Thank you for having chosen a Narvi sauna heater. To make 
the most of your sauna heater please read the manual 
carefully before you start installing and using it and keep 
the manual for future reference. This user manual contains 
the technical data of your sauna heater and installation, 
use and maintenance instructions.

The products are meant only to be used as a sauna heater 
and for heating the sauna. Do not modify the design of 
the sauna heater and use only spare parts and accessories 
recommended by the manufacturer. The data plate includ-
ed in the delivery of the sauna heater must be glued on the 
sauna heater, preferably on the lower part of the cover of 
the sauna heater.

Do not heat the sauna heater if you lack sufficient knowl-
edge, if you are not allowed to use a sauna because of 
your health condition or you are under the influence of 
substances causing intoxication. Sauna heaters must not 
be used by underage people. Do not leave children in the 
sauna without supervision. A sauna is not meant for drying 
clothes.

Steam Master

Height (mm)

1000

Adjustment range ± (mm)

15

Width (mm)

470

Depth (mm)

520

Diameter of the connective flue (mm)

119

Distance of the bottom edge of the 
connective flue from the floor (mm)

785

Central point of the connection from 
the above from the rear edge of the 
sauna heater (mm)

105

Weight (without stones, kg)

115

Weight of the stones, 10–15 cm (kg)

100

Size of the steam room (m³)

10–25

Thickness of the cover of the furnace 
(mm)

10

1.1 Technical data

Summary of Contents for Steam Master

Page 1: ...GB Made by NARVI Oy Finland Narvi Steam Master Installation user and maintenance instructions version 1 2...

Page 2: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en 2 GB...

Page 3: ...1 Preheating 7 3 2 Regulation of the height 7 3 3 Connection with the smoke flue 7 3 4 Changing of the opening direction of the firebox door 7 3 5 Sauna heater stones 8 3 6 Installation of a tunnel sa...

Page 4: ...auna heater must be glued on the sauna heater preferably on the lower part of the cover of the sauna heater Do not heat the sauna heater if you lack sufficient knowl edge if you are not allowed to use...

Page 5: ...y clearances causes a fire hazard If required additional information can be obtained from the regional branch of the rescue board 2 3 1 Structure made of combustible materials The safety clearances ar...

Page 6: ...d to a separate smoke flue A smoke flue made of bricks must be at least the so called half brick smoke flue 2 5 Ventilation Ventilation of the steam room should be sufficiently efficient and should fu...

Page 7: ...e draft Any leaks in the con nective flue also reduce the draft therefore the connections must be sealed with fireproof sealing material Leakage in the connective flue causes combustion gases formed i...

Page 8: ...ter must not be used without air flow adjusting plates 3 5 Sauna heater stones We recommend that you use Kota olive dolerite stones Natural stones are not suitable to be used as sauna heater stones 10...

Page 9: ...h drawer is closed the power of the sauna heater is at its lowest and the burning time is longer If it soughs too much in the sauna heater reduce the draft To do this close the ash drawer halfway or c...

Page 10: ...that there is no glowing coal in the firebox Otherwise fumes may be released in the sauna Carbon monoxide is an odourless and colourless toxic gas If you have not used the sauna heater and smoke flue...

Page 11: ...rranty covers normal family use provided use installation and maintenance meet the requirements stipulated in the instructions The warranty period starts form the moment that the goods are delivered t...

Page 12: ...s to combustible materials Emission of combustible products Durability Surface temperature Release of dangerous substances Cleanability Flue gas temperature Mechanical resistance Thermal output and En...