background image

NARVI SOFTY 

6,8kW, 9kW, 10,5kW

FI

SE

GB

DE

RU

ASENNUS – JA KÄYTTÖOHJE

INSTALLATIONS- OCH BRUKSANVISNING

INSTALLATION AND INSTRUCTION MANUAL

INSTALLATIONS- UND BETRIEBSANLEITUNG

ИНСТРУКЦИЯ ПО МОНТАЖУ 

И ЭКСПЛУАТАЦИИ

Summary of Contents for SOFTY 10,5kW

Page 1: ...NARVI SOFTY 6 8kW 9kW 10 5kW FI SE GB DE RU ASENNUS JA K YTT OHJE INSTALLATIONS OCH BRUKSANVISNING INSTALLATION AND INSTRUCTION MANUAL INSTALLATIONS UND BETRIEBSANLEITUNG...

Page 2: ......

Page 3: ...tt eik alittaa Taulukko 1 SOFTY kiukaan asennustiedot Saunan minimikorkeus on m ritelty taulukossa 1 samoin kuin minimisuojaet isyydet Varmista ett kiinnityslevyn ruuveille on riitt v n tukeva kiinnit...

Page 4: ...mp tila anturiin johdon voi katkaista sopivan mittaiseksi Kuva 1 SOFTY kiukaan suojaet isyydet Kiukaan asennus sein syvennykseen C min B min A min min 3 cm A min A min max 30 cm A min min 60cm Max 90c...

Page 5: ...nappeja painetaan Kuva 7 On Off merkkivalo Esiajastus keltainen P ll olo aika vihre L mp tila pun SET 3 2 Softy kiukaan asennus ja kivien ladonta Kiuas on lattialle asennettava malli Kiukaan asennuks...

Page 6: ...l oloajan asetukset vaikuttavat vain kyseiseen saunomiskertaan Painamalla SET nappia keltainen LED vilkkuu ja n ytt n tulee nollat T m n j lkeen voidaan napeilla valita haluttu esiajastus 30 min porta...

Page 7: ...an p ll 2 5 tuntia 1 Kytket n virta I O napista 2 Painetaan SET nappia keltainen led vilkkuu 3 Painetaan SET nappia toisen kerran vihre LED vilkkuu 4 Painetaan tai nappia niin monta kertaa ett n yt ss...

Page 8: ...saunaan tai pukutilaan 5 3 Alakortti j nnite 230 V 3N 50 Hz virta 16 A kiukaan teho max 10 5 kW suojaus IPX4 ylil mp suojaus 144 C Sulake 50 mA 6 SAUNAN ILMANVAIHTO Saunan ilmanvaihto on j rjestett v...

Page 9: ...puute est v t heit k ytt m st laitetta turvallisesti ellei heid n turvallisuudestaan vastaava henkil valvo heit tai ole opastanut heille laitteen k ytt Lapsia on valvottava jotteiv t he leiki t ll lai...

Page 10: ...idas eller underskridas Tabell 1 Installationsdata f r SOFTY aggregat Bastuns minimih jd samt minimis kerhetsavst nden anges i tabell 1 F rs kra dig om att f stunderlaget f r f stplattans skruvar r ti...

Page 11: ...temperaturgivaren Du kan kapa ledningen till nskad l ngd Bild 1 Skyddsavst nd till bastuaggregatet SOFTY Installation av bastuaggregatet i en v ggnisch C min B min A min min 3 cm A min A min max 30 c...

Page 12: ...knapparna Bild 7 Diodlampa On Off F rvalstid gul P kopplad tid gr n Temperatur r d SET 3 2 Att installera bastuaggregatet Softy och rada stenarna Bastuaggregatet r en modell som installeras p golvet V...

Page 13: ...du trycker ned knappen SET b rjar den gula diodlampan blinka och det visas nollor i rutan Efter det kan du v lja den nskade f rvalstiden via knapparna i steg p 30 minuter Du sparar den inst llda f rv...

Page 14: ...ryck ner knappen SET den gula diodlampan blinkar 3 Tryck ner knappen SET en andra g ng den gr na diodlampan blinkar 4 Tryck ner knappen eller upprepade g nger tills det st r 2 30 i rutan 5 Tryck ner k...

Page 15: ...stuns omkl dningsrum 5 3 Nedre kort sp nning 230 V 3N 50 Hz str m 16 A bastuaggregatets effekt max 10 5 kW kapslingsklass IPX4 verhettningsskydd 144 C s kring 50 mA 6 VENTILATION I BASTUN Bastun skall...

Page 16: ...stenar och metalldelar kan orsaka br nns r Man f r bara kasta litet vatten i s nder p bastuaggregatets stenar d det f r ngade vattnet r br nnande hett Detta aggregat r inte avsett att anv ndas av bar...

Page 17: ...1 Table 1 Installation information for SOFTY heaters The minimum height of the steam room and minimal safety clearances are shown in table 1 Make sure that the surface onto which the fastening plates...

Page 18: ...no connector in place to the temperature sensor You can cut the conductor to a suitable length Figure 1 Minimal safety clearances for the SOFTY heater The installation of a heater in a wall recess C...

Page 19: ...fter that will be displayed the temperature that is being set via the buttons Figure 7 On Off signal light Preset timing yellow Power on time green Temp red SET 3 2 Installing the Softy heater and pil...

Page 20: ...the SET button is depressed the yellow LED will flash and an array of zeros will be displayed After this the desired preset time can be selected in steps of 30 min using the buttons The preset time se...

Page 21: ...r is desired to be switched on for 2 5 hours at a time 1 Switch on the power using the I O button 2 Depress the SET button the yellow LED flashes 3 Depress the SET button a second time the green LED f...

Page 22: ...er card voltage 230 V 3N 50 Hz amperage 16 A heater capacity max 10 5 kW protection class IPX4 overheating protection 144 C fuse 50 mA 6 AIR EXCHANGE FOR THE STEAM ROOM The air exchange in the steam r...

Page 23: ...ck of experience or knowledge may hinder the safe operation of the equipment if the person who is responsible for safety cannot supervise them or instruct them in the use of the equipment Children may...

Page 24: ...Tabelle 1 Informationen zum Aufbau von SOFTY fen Die Mindesth he des Saunaraums sowie die Mindestsicherheitsabst nde werden in Tabelle 1 dargestellt Stellen Sie sicher dass die Oberfl che auf der die...

Page 25: ...er Das Kabel kann auf passende L nge abgeschnitten werden Abbildung 1 Mindestsicherheitsabst nde f r den SOFTY Ofen The installation of a stove in a wall recess C min B min A min min 3 cm A min A min...

Page 26: ...lb Einschalt dauer gr n Temp rot SET 3 2 Aufstellung des Saunaofens Softy und Beladen der Steine Der Saunaofen ist ein Modell das auf den Boden gestellt wird Bei der Aufstellung m ssen die angegebenen...

Page 27: ...nschaltdauer wirken sich nur auf die jeweilige Saunarunde aus Nach dem Dr cken der SET Taste blinkt die gelbe LED und es werden Nullen angezeigt Danach kann mit den Tasten die gew nschte Vorlaufdauer...

Page 28: ...te die gelbe LED blinkt 3 Bet tigen Sie die SET Taste erneut die gr ne LED blinkt 4 Bet tigen Sie die Tasten oder so oft bis die Zeit 2 30 angezeigt wird 5 Bet tigen Sie die SET Taste die rote LED bli...

Page 29: ...e IPX4 berhitzungsschutz 144 C Sicherung 50 mA 6 LUFTAUSTAUSCH IM SAUNARAUM Der Luftaustausch im Saunaraum muss so effizient wie m glich vonstatten gehen um ausreichend Sauerstoffgehalt und Frischluft...

Page 30: ...rfahrung oder Wissen den sicheren Betrieb der Einrichtung gef hrden k nnten verwendet werden Dies sollte nur unter Aufsicht oder Anleitung der f r die Sicherheit zust ndigen Person geschehen Kinder d...

Page 31: ...SOFTY 10 5 907118 RU 1 1 2 3 4 5 2 3 1 1 5 3 1 1 1 SOFTY 1 1 400 V 3N A B C D 3 3 2 A SOFTY 907116 6 8 5 8 190 12 12 70 3 120 5x1 5 3x10 SOFTY 907117 9 8 14 190 12 12 70 3 120 5x2 5 3x16 SOFTY 907118...

Page 32: ...min min 60cm Max 90cm jausyksikk ei saa in syvennykseen 10cm Kuva 4 5cm 5cm 2 3 13 90 60 3 2 3 5 15 2 1 3 0 10 3 min 60cm Max 90cm HUOM Ohjausyksikk ei saa asentaa sein syvennykseen Kuva 5 2 1 Fasteni...

Page 33: ...I O SET ON OFF ON OFF 4 2 60 C 115 C 7 ON OFF SET 3 2 Softy 4 5 5 10 Kuva 2 6 6 Kuva 6 Kuva 3 2 Kuva 3 3 6 Kuva 2 Kuva 6 Kuva 3 2 Kuva 3 3 4 Kuva 3 6 6 Kuva 2 Kuva 3 1 6 6 Kuva 6 Kuva 3 2 Kuva 3 3 Kuv...

Page 34: ...4 3 ON OFF 30 4 4 15 4 5 ON OFF ON OFF 3 3 3 4 6 1 SET 30 SET SET SET 60 C 115 C SET ON OFF ON OFF...

Page 35: ...4 7 3 d 1 d 1 d 2 d 3 d 1 d 2 d 3 SET SET 1 d E01 E02 4 8 100 C 2 5 1 I O 2 SET 3 SET 4 2 30 5 SET 6 14 7 SET 3 1 I O 2 SET 3 3 00 4 SET 5 SET 6 SET SET I O SET 1...

Page 36: ...1 SET 2 ON OFF 3 SET 4 SET 5 SET 5 5 1 60 C 115 C 24 4 5 2 IPX4 5 3 230 3 50 16 A 10 5 IPX4 144 C 50 6 100 1000 500 100 150 15 1 SET 2 3 SET 4 SET 5 1...

Page 37: ...7 8 9 1 2 10 400V 3N t X1 2 2 3 1 4 X1 1 X1 3 X1 4 Disp VA1 VA2 VA3 YKS A1 A2 NTC B1 B2 NTC 12V CTL J7 J8 N L1 L1 N CTL L2 L2 PE PE L3 L3 NTC ON OFF...

Page 38: ......

Page 39: ......

Page 40: ...Narvi Oy Yritt j ntie 14 27230 Lappi Finland Tel 358 207 416 740 www narvi fi 4 2013...

Reviews: