background image

TYYPPI

X min. mm

NME  450

125

NME  600

125

NME  900

175

125

112

125

255

Min 

30

0

X

Kiukaan asennus seinäsyvennykseen

min. 20 cm

max. 30 cm

A

min. 2 cm

C

B

min. 12 cm

A

D

Huom! NM 800 ja NM 900 kiuasta
EI saa asentaa seinäsyvennykseen.

Figure 2.

Figure 1.

Installation of stove in a wall recess.

NME 900 stoves are not allowed to 
install into wall reces.

3. INSTALLATION

Fasten the mounting plate to the wall with the screws which follow the delivery according 
to the picture 2.   

Stage 1: ELECTRICAL CONNECTION

-  The connection of the sauna stove to the electrical network can only be carried out by 
a qualified electrician in accordance with the valid regulations.
-  A rubber cable of type H07RN-F or similar must be used as a connection cable. The 
cross-sectional surface of the cable and the size of the fuse can be seen in Table 1.
-  The cross-sectional surfaces of the wires which are connected from the sauna stove to 
the heating and signal lights must correspond to the feed cable of the sauna stove.
-  First connect the connection cable to the terminal strip in the connection box of the 
sauna stove.
-  Turn the stone room+electrical box upside down.
-  Open the bottom of the electrical box.
-  Connect the connection cable.
-  Fasten the bottom of the box.
-  Turn the stone room+electrical box right 
side up.

Stage 2:  INSTALLATION ON THE WALL

-  Draw in the lugs on the rear side of the 
sauna stove through the mounting slots of the 
mounting plate on the wall (Fig.6A).
-  Push the upper edge of the mounting 
plate between the jacket and upper frame of 
the sauna stove and make sure that the lugs 
of the stove are wedged into the slots of the 
mounting plate on the wall (Figure 6B).
-  Tighten the upper edge of the sauna stove 
with a locking screw (Figure 6C).
-  The stone basket is now locked in the jacket and on the mounting plate of the sauna 
stove. 

A

B

C

Figure 6.

Reviews: