NARDA SRM-3006 Manual Download Page 8

8

SRM – WHAT FOR?

SRM: FOR EVERYTHING

Electromagnetic fields always consist of an electrical and 
a magnetic field component. Limit values are therefore 
specified for both the electric as well as the magnetic 
field strength.

The electric and magnetic field strengths at a distance 
from the source are in a fixed relationship, so it is suffi- 
cient to measure just one of the two components. This 
relationship does not apply close to the source, so both 
components must be determined separately.

The wavelength of the radiation determines the  location 
of  the  near-field  and  the  far-field.  The  near-field  of  a 
long  wave  transmitter  extends  for  several  kilometers. 
The near-field for mobile phone antennas ends within 
the space of about one meter.

Narda Safety Test Solutions has developed a thoroughly 
researched  range  of  measuring  antennas.  They  make 
the SRM into a universal measuring set for electric and 
magnetic fields – from long wave up to the latest gene- 
ration of mobile phone frequencies.

The isotropic (three-axis) 
 measuring antenna for electric 
fields (E-fields) up to 3 GHz 
is the all-round solution for 
trouble-free measurements 
covering VSW to UMTS.

Inside the isotropic electric  
field measuring antenna, 
 showing three dipoles  
arranged at mutual  
right angles.

Summary of Contents for SRM-3006

Page 1: ...SRM WHEN SAFETY COUNTS SRM 3006 SELECTIVE RADIATION METER FOR ELECTROMAGNETIC FIELDS UP TO 6 GHz...

Page 2: ...ise be impossible National and international authorities have fixed limit values for such fields to prevent harmful effects The field strengths allowed in the occupational environment are usually high...

Page 3: ...rities These in turn can take advantage of the measurement services offered by organizations and independent providers There is really only one way to make sure everything is safe TETRA GSM UMTS CDMA...

Page 4: ...to evaluate results The Selective Radiation Meter SRM 3006 from Narda Safety Test Solutions combines the analysis features of a spectrum analyzer with the simple application of a wideband measuring s...

Page 5: ...and Play The results can be shown in physical units e g electric field strength in V m magnetic field strength in A m and power density in W cm2 or directly as a percentage of the limit values for exa...

Page 6: ...aging over several measurement points When using the isotropic measuring antennas for the SRM you don t need to worry about the direction of the field either the instru ment doesn t miss a thing And y...

Page 7: ...e to falsify Screenshot of a Safety Evaluation result The calibration certificate records the traceability of the calibration of the instrument and antenna to recognized standards with accreditation i...

Page 8: ...es the location of the near field and the far field The near field of a long wave transmitter extends for several kilometers The near field for mobile phone antennas ends within the space of about one...

Page 9: ...ncies from 420 MHz to 6 GHz For rapid non directional measurements e g covering mobile phone frequencies Three axis isotropic E field antenna for frequencies from 27 MHz to 3 GHz The measuring antenna...

Page 10: ...o DVB T DAB mobiles GSM UMTS LTE and wireless WLAN WiMAX as well as a summary of the results in the form of an overall value Or Level Recorder mode which can even record pulsed radar signals as numeri...

Page 11: ...the sum of all P CPICH levels as an overall value Total The analog measured value for the frequency channel is also shown for comparison You can also set a factor that the SRM can use to extrapolate...

Page 12: ...me a flood though The start and sequence of measurements can be timer controlled or triggered when a threshold is crossed The SRM then summarizes the data sets in a clear display Particularly convenie...

Page 13: ...are set of batteries you can run the equipment for a whole day without needing AC line power Safety Evaluation in a residential area Is it really only the mobile phone base stations that are the sourc...

Page 14: ...cession and performs the necessary tasks This saves time avoids incorrect measurements and means that the results from different locations are comparable and reproducible The SRM can do a lot of thing...

Page 15: ...or Level Recorder mode Meaningful measurement involves a process which begins with configuring the instrument and ends with the evaluation documentation and management of the measured data The SRM 300...

Page 16: ...retained in the background Selective measurement in the time domain is unique Pulsed signals can be displayed directly in Scope mode with time intervals ranging from hours right down to microseconds...

Page 17: ...e Evaluation of a Spectrum Analysis using the Peak Table The list of the highest field strengths and their corresponding frequencies service names and even the names of the service providers if these...

Page 18: ...Many of its features show their real worth in difficult environments the voice recorder for spoken comments the rough textured rear panel ensuring you have a good grip and the large area key pad that...

Page 19: ...evice If required the SRM evaluates directly according to safety standards Shown here ICNIRP occupational and general public limit value curves 1 10 100 1k 10k 100k 1M 10M 100M 1G 10G 100G 10 100 1k 1...

Page 20: ...analyzing the field exposure level in detail as a graph or table with display of individual values and calculation of the exposure due to entire frequency ranges For a rapid overview of the field expo...

Page 21: ...gle axis H field antenna up to 300 MHz Antenna cables RF cable 1 5 m RF cable 5 m Tripod Tripod adapter for single and three axis antennas Tripod adapter for three axis antennas Transport Soft case or...

Page 22: ...inually building upon its reputation in this sector Our three facilities are located at Hauppauge Long Island USA Pfullingen Germany and Cisano Italy It is our aim to provide all our customers with ta...

Page 23: ...ng calibration and training OUR COMPLETE RANGE Selective high frequency test equipment SRM 3006 the tester that selectively detects and measures every source in the range from 9 kHz to 6 GHz With a se...

Page 24: ...Hauppauge NY 11788 USA Tel 1 631 231 1700 Fax 1 631 231 1711 E Mail nardasts L 3com com www narda sts us Narda Safety Test Solutions Srl Via Leonardo da Vinci 21 23 20090 Segrate Milano Italy Tel 39...

Reviews: