background image

 

 
 

 

 
 

 

Safety consideration 

 

 

 

  SAFETY RECOMMENDATIONS AND INSTRUCTIONS

 

 
This product has been designed, produced and tested in Italy, and it left the factory in conditions fully 
complying with the current safety standards. To maintain it in safe conditions and ensure correct use, 
these general instructions must be fully understood and applied before the product is used. 
 

  When the device must be connected permanently, first provide effective grounding; 

  If the device must be connected to other equipment or accessories, make sure they are all safely 

grounded; 

  In case of devices permanently connected to the power supply, and lacking any fuses or other 

devices of mains protection, the power line must be equipped with adequate protection 
commensurate to the consumption of all the devices connected to it; 

  In case of connection of the device to the power mains, make sure before connection that the 

voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual 
mains; 

  Devices in Safety Class I, equipped with connection to the power mains by means of cord and plug, 

can only be plugged into a socket equipped with a ground wire; 

  Any interruption or loosening of the ground wire or of a connecting power cable, inside or outside the 

device, will cause a potential risk for the safety of the personnel; 

  Ground connections must not be interrupted intentionally; 

  To prevent the possible danger of electrocution, do not remove any covers, panels or guards 

installed on the device, and refer only to NARDA Service Centers if maintenance should be 
necessary; 

  To maintain adequate protection from fire hazards, replace fuses only with others of the same type 

and rating; 

  Follow the safety regulations and any additional instructions in this manual to prevent accidents and 

damages. 

 

 
 
 
 

Summary of Contents for PMM SB-10

Page 1: ...erial Number in a side of the box Serial Number is in the form 0000X00000 The first four digits and the letter are the Serial Number prefix the last five digits are the Serial Number suffix The prefix...

Page 2: ...AFETY SYMBOLS You now own a high quality instrument that will give you many years of reliable service Nevertheless even this product will eventually become obsolete When that time comes please remembe...

Page 3: ...Introduction 2 1 2 2 Initial inspection 2 1 2 3 Environment 2 1 2 4 Return for service 2 1 2 5 Equipment cleaning 2 1 2 6 PMM SB 10 Installation and use 2 2 2 7 External DC supply 2 3 2 8 Installation...

Page 4: ...Figure Page 1 1 PMM SB 10 front panel 1 3 1 2 PMM SB 10 rear panel 1 3 2 1 Single SB 10 installation example 2 2 2 2 Multiple SB 10 installation example 2 2 Tables Table Page 1 1 PMM SB 10 Technical...

Page 5: ...In case of connection of the device to the power mains make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains Devic...

Page 6: ...arda Safety Test Solutions S r l Via Benessea 29 B 17035 Cisano sul Neva SV ITALY complies with the following European Standards Safety CEI EN 60950 CEI EN 60950 A4 CEI EN 60950 A11 EMC EN 61326 1 EN...

Page 7: ...fferent measuring points and or working on different frequency and full scale ranges it is possible to have a chain up to five SB 10 to connect up to 50 remote devices The PMM SB 10 is powered by an E...

Page 8: ...00 kHz 3 GHz 1 1000 V m Electric Field Probe EP 333 100 kHz 3 6 GHz 0 15 300 V m Electric Field Probe EP 183 1 MHz 18 GHz 0 8 800 V m Electric Field Probe EP 408 1 MHz 40 GHz 0 8 800 V m Electric Fiel...

Page 9: ...vice 5 Fiber optic connector 7 Device 6 Fiber optic connector 8 Device 7 Fiber optic connector 9 Device 8 Fiber optic connector 10 Device 9 Fiber optic connector 11 Device 10 Fiber optic connector 1 7...

Page 10: ...1 4 General Information This page has been left blank intentionally...

Page 11: ...ative The instrument should be stored and shipped in a clean dry environment which is specified to be within the following limitations Temperature Humidity 20 to 70 C 95 relative 2 5 Return for servic...

Page 12: ...10 Switching Control Box can function together with several NARDA isotropic probes with a wide frequency and level operating range The following figure shows an example of SB 10 interconnection Fig 2...

Page 13: ...y the PC USB port 2 9 Installation To install the PMM SB 10 simply connect the provided optical fiber to the DEVICE X connector on the front panel taking care of the insertion key then connect the oth...

Page 14: ...2 4 Installation This page has been left blank intentionally...

Page 15: ...ral PMM EP600 EP601 EP602 EP603 are connected to the PMM SB 10 and each of them need to be set with a different address it is suggested to use the utility SetAddEP600 provided with the probe self Plea...

Page 16: ...h up to 10 device connected at the same time placed at different measuring locations and or working on different frequencies and full scale ranges by using a single RS232 port to the PC After having c...

Page 17: ...the device connected to the SB 10 Address It shows the address that must be assigned at the device connected at the SB10 the address range is from 00 to 10 Reading Status It shows the current process...

Page 18: ...cess the software shows the Release and Date of the device connected to the SB 10 The default address of each device is 00 and the utility will show the message ADDRESS received 00 To change the addre...

Page 19: ...ike to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would be glad...

Page 20: ...Suggerimenti Commenti Note Suggestions Comments Note...

Reviews: