FEATURES 

The Narda Broadband Meter NBM-520 is designed for on-site use. The 
concept focuses on simple operation and the range of functions has 
been deliberately kept to the main features necessary for performing 
precision field measurements. 
 

Display and operation 

 

Operated by weatherproof foil keypad using just 4 buttons  
with perceptible click point 

 

Backlit monochrome LCD with selectable illumination time,  
easy to read even in bright daylight 

 

Result display and evaluation 

 

4 measurement modes selectable using the Mode button: 
Instantaneous value (ACT) 
Maximum (MAX) 
Time average (AVG) 
Spatial average (SPATIAL) 

 

Display units selectable using the Units button:  
V/m, A/m, mW/cm

2

, W/m

2

 when using flat probes,  

% of limit value when using shaped probes 

 

Hold button for “freezing” the display value 

 

Automatic adjustment, application of calibration data 

 

Intelligent probe interface recognizes the NBM probe type and 
automatically imports and applies the correction values stored 
in the probe during calibration 

 

Fully automatic zero point adjustment with user definable time 
interval 

 

Warning functions 

 

Audible and visible warning signals for high field strengths:  
Alarm threshold can be set from a PC 

 

 

Everything at a glance. The clearly arranged 

display is easy to read. 

The optical interface connector and AC 

adapter / charger connector compartment is 

sealed with a rubber cap. The tilt stand 

provided in addition to the tripod bush can be 

used to place the instrument securely on a 

flat surface. 

Probe model 

Battery level 

Result unit 

Field type 

Status 

Result 

Mode 

Summary of Contents for nbm-520

Page 1: ...h frequency to microwaves Non directional measurement using isotropic probes for applications in the frequency range 100 kHz to 60 GHz Intelligent probe interface with automatic detection of probe par...

Page 2: ...parameters and calibration data so they can be used with any instrument in the NBM 500 family APPLICATIONS The NBM 520 is used to make precision measurements to establish human safety particularly in...

Page 3: ...ton V m A m mW cm 2 W m 2 when using flat probes of limit value when using shaped probes Hold button for freezing the display value Automatic adjustment application of calibration data Intelligent pro...

Page 4: ...n enables data communication with the smaller NBM 520 so it can be used as an extended probe handle This means that probes can be situated remotely from the NBM 550 without any metallic cables to adve...

Page 5: ...signation EF0391 EF1891 EF5091 EF5092 EF6091 HF3061 HF0191 Ex5091 Mobile radio telecommunications z z z z z Radio TV broadcasting z z z z z Satellite communications z z z Radar z Industry Heating and...

Page 6: ...hold adjustable by PC software INTERFACES Optical interface Serial full duplex 115200 baud no parity 1 start and 1 stop bit Probe interface Plug and play auto detection compatible with all NBM series...

Page 7: ...391 E field for NBM 100 kHz 3 GHz isotropic 2402 01 Probe EF1891 E field for NBM 3 MHz 18 GHz isotropic 2402 02 Probe EF5091 E field for NBM thermocouple 300 MHz 50 GHz isotropic 2402 03 Probe EF6091...

Reviews: