Narada Power Source CO., LTD              TT Series Battery Operation Manual 

Table 3-1 Discharge End-voltage 

 

Discharge Current

A

 Discharge 

End 

Voltage

V/Cell

 

I

0.2C 

1.80 

0.2C

I

0.5C 

1.70 

0.5C

I

1.0C 

1.55 

I

1.0C 

1.30 

3. Temperature 

3.1.

 

Available Capacity Vs. Ambient Temperature 

Temperature affects capacity of the battery. Fig. 3-1 is the available capacity curve vs. 

ambient temperature. if the temperature drops, the capacity will decrease, for example, the 

capacity will decrease to 80% of rated capacity if temperature decreases from 25

 to 0

; and 

too low temperature will cause battery long term insufficient charged, also will cause no 

discharge and negative plates sulfate.       

Though VRLA battery can be operated at -15

, the standard data is the test result at 25

The capacity will increase when temperature raises. For example the capacity will increase 

to 102% of rated capacity if temperature increase from 25

 to 50

. But it will quicken plates’ 

corrosion and water loss if temperature raises, and shorten battery’s life. 

-40

-30

-20

-10

0

10

20

30

40

50

60

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Ambient Tempersture(

)

el

ectric

 Cap

acity(

%

)

Fig.3-1 Available Capacity VS. Ambient Temperature 

 

 13

Summary of Contents for TT series

Page 1: ...er Source CO LTD TT Series Battery Operation Manual VALVER REGULATED SEAL LEAD ACID BATTERY OPERATION MANUAL Version V3 0 TT Series Narada Power Source Co Ltd Email intl narada biz Website www naradab...

Page 2: ...5 Dimension and sketch map 6 6 Terminal sketch 6 7 Working Principal 4 ter Two Technical Characteristics 7 1 Charge Characteristics Curve 7 3 Internal resistance and short circuit current 7 4 Dischar...

Page 3: ...d be same as the old ones in model and type Warning Do not smoke or use fire near batteries Warning Do not use any organic cleanser to clean batteries Warning Do not put the batteries on fire or they...

Page 4: ...rator 1 5 Flame retardant ABS material container and cover compliant with UL94 V 0 1 6 Self regulating pressure relief valve 2 Main Applications 2 1 Communication System 2 2 UPS 3 Types and Dimensions...

Page 5: ...CO LTD TT Series Battery Operation Manual 5 Dimension and sketch map TT12V38 TT6V200A TT12V93 168 6 62 212 8 35 308 12 14 220 8 67 TT12V52 121 4 77 245 9 65 6 Terminal sketch 15 18 M8 TT6V200A TT12V3...

Page 6: ...y TT battery adopts design of barren liquor and utilizes AGM micro porous glass fiber separator Thus there is a path existing between the positive and the negative Also special alloy grid is chosen to...

Page 7: ...ed The table 2 1 shows the internal resistance and short circuit current in fully charged state according to the IEC60896 standard Table 2 1 Internal resistance and short circui Type Internal Resistan...

Page 8: ...8 293 8 205 1 164 3 131 4 73 9 54 2 42 6 35 7 30 9 24 3 20 3 17 0 11 3 9 5 1 85V 410 1 280 5 198 2 159 4 127 6 72 8 53 3 41 9 35 2 30 6 24 0 20 1 16 8 11 1 9 4 End voltage per cell 5min 15min 30min 4...

Page 9: ...9 4 13 8 10 9 9 11 7 83 6 18 5 01 4 21 2 76 2 30 1 85V 129 76 7 51 3 38 6 31 5 18 6 13 4 10 7 8 89 7 66 5 98 4 97 4 16 2 70 2 28 TT12V93 1 60V 302 163 98 5 71 4 57 7 33 1 25 9 19 9 17 9 15 0 11 7 9 67...

Page 10: ...5 38 2 32 8 21 4 18 1 End voltage per cell 5min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 12h 20h 24h TT12V38 1 60V 229 129 81 1 60 8 49 3 28 4 20 7 16 4 13 8 11 9 9 21 7 60 6 39 4 09 3 43 1 67V 221...

Page 11: ...9 61 0 36 5 26 2 21 1 17 5 15 1 11 8 9 83 8 28 5 44 4 60 TT12V93 1 60V 505 285 178 134 108 62 4 49 3 38 1 34 2 28 9 22 6 18 7 15 8 10 0 8 39 1 67V 487 280 177 133 108 62 3 48 6 38 1 34 1 28 9 22 4 18...

Page 12: ...battery and manufacture technology In using process the factors that influence the actual capacity are discharge rate depth of discharge end voltage and temperature 2 3 Discharge Rate The discharge ra...

Page 13: ...ed capacity if temperature decreases from 25 to 0 and too low temperature will cause battery long term insufficient charged also will cause no discharge and negative plates sulfate Though VRLA battery...

Page 14: ...or TT series is 2 25V cell And temperature compensate coefficient is 3mV cell The formula to calculate float voltage at different temperature VT 2 25 T 25 0 003 VT Floating charge voltage at T tempera...

Page 15: ...is only 2 5 years t25 tT 2 T 25 10 Notes T the actual ambient temperature tT is designed life at T ambient temperature t25 is designed life at 25 ambient temperature The heats disseminate performance...

Page 16: ...lows The charge time is 18 24 hours the charge time can be shortened when the batteries were not deep discharged e g the charge time of 20 DOD batteries can be shortened to 10 hours On condition of co...

Page 17: ...rvice life the batteries should be correctly inspected and maintained The maintenance methods of TT batteries are recommended as follows 6 1 Monthly Maintenance Implement following inspection every mo...

Page 18: ...lect the performance of rectify to transfer floating charge to equalization charge If the rectify cannot transfer charge modes because of its wrong performance or no adjustment the battery system is a...

Page 19: ...which are difficult to transfer to active Pb After sales Service Customer Service Hotline P R China Narada Power Source Co Ltd No 459 Wensan Road Hangzhou China Tel 86 571 28827007 28827008 Fax 86 571...

Page 20: ...n Manual Annex 1 VRLA Battery Regular Maintenance Record Type Place Test Status Qty Total Voltage V Current A Room Temperature No Voltage V No Voltage V 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10...

Reviews: