19
W415-1016 / B / 03.13.12
7.0 OPERATION
When lit for the fi rst time, the appliance will emit a slight odour for a few hours. This is a normal temporary con-
dition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not
occur again. Simply open a window to suffi ciently ventilate the room. After extended periods of non-operation
such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours.
This is caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the
room.
7.1 LIGHTING AND OPERATING INSTRUCTIONS
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY,
A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
INITIAL LIGHTING OF THE PILOT AND MAIN BURNERS MUST BE DONE WITH
THE GLASS DOOR OFF.
DO NOT CONNECT VALVE OR WALL SWITCH TO
ELECTRICITY.
SEE INSTALLATION INSTRUCTIONS.
A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH
AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS
AND NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND
WILL SETTLE ON THE FLOOR.
WHAT TO DO IF YOU SMELL GAS:
• TURN OFF ALL GAS TO THE FIREPLACE.
• OPEN WINDOWS.
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR
BUILDING.
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOUR’S PHONE.
FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
C. DO NOT TRY TO REPAIR ANY PART OF THIS ASSEMBLY. CALL A QUALIFIED
SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE
OR EXPLOSION.
D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER.
IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE
FIREPLACE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS
CONTROL WHICH HAS BEEN UNDER WATER.
TO TURN OFF GAS
1. TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS
TO BE PERFORMED.
2. TURN MANUAL SHUTOFF VALVE CLOCKWISE
TO OFF. DO NOT
FORCE.
1. STOP! READ ALL INFORMATION OF OPERATING AND LIGHTING
INSTRUCTIONS BEFORE PROCEEDING.
2. TURN OFF ELECTRIC POWER TO THE FIREPLACE.
3. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH
AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY
HAND.
4. OPEN THE GLASS DOOR.
5. TURN MANUAL SHUTOFF VALVE CLOCKWISE
TO OFF.
6. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF YOU
SMELL GAS INCLUDING NEAR THE FLOOR, STOP! FOLLOW
“B” OF THE OPERATING INSTRUCTIONS. IF YOU DON’T
SMELL GAS GO TO THE NEXT STEP.
7. TURN MANUAL SHUTOFF VALVE COUNTER-CLOCKWISE
TO ON.
8. CLOSE THE GLASS DOOR.
9. TURN ON ALL ELECTRIC POWER TO THE FIREPLACE.
10.TURN ON MAIN BURNER.
IF THE APPLIANCE WILL NOT OPERATE, FOLLOW THE INSTRUCTIONS “TO
TURN OFF GAS” AND CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER.
OPERATING INSTRUCTIONS
W385-0613 / A
FOR YOUR SAFETY READ BEFORE OPERATING
LIGHTING INSTRUCTIONS