background image

WARNING:

 IF YOU DO NOT FOLLOW THESE INSTRUCTIONS 

A FIRE OR EXPLOSION MAY RESULT CAUSING   

PERSONAL INJURY OR LOSS OF LIFE.

SEE INSTALLATION INSTRUCTIONS.
A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH 
AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS 
AND NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND 
WILL SETTLE ON THE FLOOR.
WHAT TO DO IF YOU SMELL GAS:

‡

 TURN OFF ALL GAS TO THE FIREPLACE.

‡23(1:,1'2:6
‡'212

T TRY TO LIGHT ANY APPLIANCE.

‡'212

T TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR 

BUILDING.

‡,00(',

ATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOUR’S PHONE.

FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.

‡,)

 YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

C. DO NOT TRY TO REPAIR ANY PART OF THIS ASSEMBLY. CALL A QUALIFIED 
SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE 
OR EXPLOSION.
D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER. 
IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE 
FIREPLACE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS 
CONTROL WHICH HAS BEEN UNDER WATER.

TO TURN OFF GAS

2. TURN MANUAL SHUTOFF VALVE CLOCKWISE 

 TO OFF. DO NOT 

FORCE.

1.  STOP! READ ALL INFORMATION OF OPERATING AND LIGHTING 

INSTRUCTIONS BEFORE PROCEEDING.

2.  THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH 

AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY 
HAND.

3.  TURN MANUAL SHUTOFF VALVE CLOCKWISE 

 TO OFF.

4.  WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF YOU 

SMELL GAS INCLUDING NEAR THE FLOOR, STOP! FOLLOW 
“B” OF THE OPERATING INSTRUCTIONS. IF YOU DON’T 
SMELL GAS GO TO THE NEXT STEP.

5.  TURN MANUAL SHUTOFF VALVE COUNTER-CLOCKWISE 

 TO ON.

6. TURN ON MAIN BURNER.

IF THE APPLIANCE WILL NOT OPERATE, FOLLOW THE INSTRUCTIONS “TO 
TURN OFF GAS” AND CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER.

OPERATING INSTRUCTIONS

W385-1902_B

FOR YOUR SAFETY READ BEFORE OPERATING

LIGHTING INSTRUCTIONS

EXACTLY, 

 PROPERTY DAMAGE,

A.

 

Locate the pilot adjustment knob on 
the bottom right of appliance.

B.

 

Push and turn the knob counter 
clockwise to the “PILOT ON” position 
and hold for a few seconds to ignite 
the pilot.

C.

 

Once the pilot is lit, slightly push the 
knob and turn counter clockwise to 
light the main burner.

D.

 

To adjust the fl ame height, push the 
knob and turn to desired height.

NOTE: When fi rst lighting the pilot, push 
the knob and hold for 30 seconds to purge 
the gas line. WARNING: Do not hold for 
more than a minute.

W415-1158 / A / 11.19.13

16  

EN

6.0 OPERATION

When lit for the fi rst time, the appliance will emit a slight odour for a few hours. This is a normal temporary con-
dition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not 
occur again. Simply open a window to suffi ciently ventilate the room. After extended periods of non-operation 
such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. 
This is caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the 
room.

6.1  LIGHTING AND OPERATING INSTRUCTIONS 

Summary of Contents for WHVF24N

Page 1: ...r gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified...

Page 2: ...MOBILE HOME 10 3 5 MOUNTING THE APPLIANCE 11 3 6 MINIMUM CLEARANCE TO COMBUSTIBLES 12 4 0 FINISHING 13 4 1 SURROUND INSTALLATION REMOVAL 13 4 2 DOOR REMOVAL INSTALLATION 13 4 3 GLASS MEDIA 14 5 0 IGN...

Page 3: ...M CLEARANCES TO COMBUSTIBLES section Side Wall see MINIMUM CLEARANCES TO COMBUSTIBLES section Rating plate see RATING PLATE INFORMATION section Surround see FINISHING section W415 1158 A 11 19 13 3 EN...

Page 4: ...ect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the appliance It is imperativ...

Page 5: ...RLY GET FRESH AIR AT ONCE HAVE HEATER SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUNG DISEASE ANEMIA THOSE UNDER THE INFLUENCE OF ALCOHOL THOSE AT HIGH ALTITUDES ARE MORE AFFECTED BY CA...

Page 6: ...positions the addition of foreign or unapproved materials or the failure to properly maintain the appliance may result in incomplete combustion of the fuel Incomplete combustion results in soot being...

Page 7: ...AX SUPPLY PRESSURE 13 WATER COLUMN LP NOT FOR USE WITH SOLID FUEL WARNING DO NOT ADD ANY MATERIAL TO THE APPLIANCE WHICH WILL COME IN CONTACT WITH THE FLAME DO NOT USE ACCESSORIES NOT APPROVED FOR USE...

Page 8: ...d to the outside atmosphere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and B Weather stripping has been added o...

Page 9: ...no door to the adjoining room the volume of the adjoining room may be added to the volume of the room with the heater to get a total unconfined space The total unconfined space 400 ft3 11 3m3 600 ft3...

Page 10: ...rdance to local codes In the absence of local codes install to the current CAN CSA B149 1 Installation Code in Canada or to the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States...

Page 11: ...s are facing upward NOTE The mounting screws must go into a wall stud or proper anchors D Mount the appliance onto the mounting bracket by placing the appliance into the slots until it is secured in p...

Page 12: ...4mm MIN 20 508mm MIN 10 254mm MIN 3 6 MINIMUM CLEARANCE TO COMBUSTIBLES MINIMUM CLEARANCES TO COMBUSTIBLES 20 508mm to top 7 177 8mm to sides 10 254mm to bottom 36 914 4mm to rear TYPICAL INSTALLATION...

Page 13: ...PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED FACING AND OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVR...

Page 14: ...mild dish soap drain rinse thoroughly and dry before placing over the burner CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION BEFORE APPLYING THE CLEANED GLASS ENSURE THAT IT IS DRY DO NOT CHANGE OR SUBST...

Page 15: ...15 EN 5 0 IGNITION SYSTEM DIAGRAM WARNING ENSURE ALL POWER IS TURNED OFF BEFORE HARD WIRING THIS APPLIANCE CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR ELECTRODE VALVE KN...

Page 16: ...CLOCKWISE TO OFF 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS IF YOU SMELL GAS INCLUDING NEAR THE FLOOR STOP FOLLOW B OF THE OPERATING INSTRUCTIONS IF YOU DON T SMELL GAS GO TO THE NEXT STEP 5 TURN MAN...

Page 17: ...hat has been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will cause a more yellow flame but can lead to carboning Opening the air shutter wi...

Page 18: ...PPLIANCE MAY BE HOT DO NOT SERVICE UNTIL APPLIANCE HAS COOLED DO NOT USE ABRASIVE CLEANERS DO NOT PAINT THE PILOT ASSEMBLY WARNING 37 1A WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION LET THE A...

Page 19: ...0 hours of operation with a recommended fireplace glass cleaner Thereafter clean as required If the glass is not kept clean permanent discoloration and or blemishes may result HOT GLASS WILL CAUSE BUR...

Page 20: ...ALER 41 1 FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING C...

Page 21: ...or combustion chamber Check that the glass logs rocks or media are correctly positioned Open air shutter to increase the primary air Check the input rate check the manifold pressure and orifice size...

Page 22: ...er heat exchanger plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts...

Page 23: ...W415 1158 A 11 19 13 23 EN 12 0 SERVICE HISTORY 43 1...

Page 24: ...ces Outdoor Fireplaces Gourmet Grills Fireplaces Heating Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie...

Reviews: