![Napoleon U405 CART User Manual Download Page 5](http://html.mh-extra.com/html/napoleon/u405-cart/u405-cart_user-manual_706474005.webp)
5
DO NOT USE A FLAME TO LEAK TEST.
LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking
while performing this test, and remove all sources of ignition. See
Leak Testing Diagram for areas to check.
1. Turn all burners controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4. If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do
not use the appliance until the leak has been corrected.
5. Turn off gas supply.
LEAK TESTING INSTRUCTIONS
GAS HOSE
• If the hose and regulator are not included by the manufacturer, then only hoses and regulators which meet national and regional codes
are to be used.
• Do not connect the appliance to a permanent gas installation.
• Ensure that the hose does not come into contact with grease, other hot drippings, or any hot surfaces on the appliance.
• Check hose regularily. In the case of rips, melting or wear, replace hose before using the appliance.
• The recommended hose length is 0.5m. The hose must not be longer than 1.5m.
• Ensure that the hose is twist and kink free when installed.
• Replace the hose before expiry date printed on the hose.
REGULATOR
The following table lists input values for the appliance.
BURNER
ORIFICE SIZE
HEAT INPUT
GAS USAGE (TOTAL)
I
II
(TOTAL)
PROPANE
BUTANE
MAIN
#60
1.45mm
13.2 kW
944 g/h
960 g/h
BACK
#58
1.5mm
4.1 kW
293 g/h
298 g/h
SIDE
#69
#57
2.3 kW
164 g/h
167 g/h
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
The regulators for both butane and propane must have a rating of at least 1200 g/h. Do not tamper with or modify regulator. Use only
regulators which supply the pressure listed in the table above.
Gas Category
I
3B/P(30)
I
3+(28-30/37)
I
2H(20)
I
2E(20)
Orifice Sizes (see above)
I
I
II
II
Gases / Pressures
Butane 30mbar
Propane 30mbar
Butane 28-30mbar
Propane 37mbar
Natural Gas 20mbar
Natural Gas 20mbar
Countries
CZ, DK, FI, GR,
NL, NO, SE
BE, CH, CZ, ES,
FR, GB, IE, IT,
PT
AT, CH, CZ, DK,
ES, FI, GB, GR,
IE, IT, NO, PT, SE
DE, LU
Summary of Contents for U405 CART
Page 36: ...36 LEAK TESTING TEST DE FUITES LEKTEST 2 x 3 4 OR 1 9 m m ...
Page 39: ...39 ...