background image

13

W415-0619  / A / 08.09.07

PART NO.  DESCRIPTION

 

W225-0216 

DOOR FRAME  

2* W562-0008  DOOR 

GASKET

3* 

W010-1736 

DOOR LATCH ASSEMBLY  

4 W010-1743  GLASS 

C

/

W

 GASKET

5* W300-0088  GLASS
6 W100-0104  BURNER 

 

7 W357-0006  IGNITOR
8 W190-0026  CONTROL, 

MODULE

9* W750-0183  WIRE 

HARNESS

10* W750-0184 

IGNITION 

CABLE

11 W200-0234  IGNITOR 

COVER

12 W200-0233  BURNER 

COVER

13 

W725-0052 

NATURAL GAS VALVE - 3.5” W.C. 

13 

W725-0053 

PROPANE GAS VALVE - 10.0” W.C.

14*  W455-0085 

NATURAL GAS ORIFICE

14*  W455-0086 

PROPANE GAS ORIFICE 

15 W500-0358  FIRESTOP 

SPACER

16 W475-0522  BACK 

PANEL

17*  W300-0094 

ACCENT GLASS (

BLACK

)

18* W385-0334 

NAPOLEON® 

LOGO

19 W290-0123  EXHAUST 

GASKET

20 W290-0125  BURNER 

GASKET

21*  W562-0046 

ROPE GASKET, BACK PANEL

26* W573-0002 

HIGH 

TEMPERATURE 

SEALANT

27*  W573-0007 

MILL PAC SEALANT 

28* W175-0204 

3” 

COUPLER

29* W175-0166 

5” 

COUPLER 

 

30*  W175-0270 

CONVERSION KIT - 

NG

 

TO

 

LP

31*  W175-0274  

CONVERSION KIT - 

LP

 

TO

 

NG

32* W175-0271 

COUPLER 

KIT

Contact your dealer for questions concerning prices and 
availability of replacement parts. Normally all parts can be 
ordered through your Napoleon® dealer or distributor. 
When ordering replacement parts always give the following 
information:

1.  

MODEL

 & 

SERIAL

 

NUMBER

 

OF

 

FIREPLACE

2.  

INSTALLATION

 

DATE

 

OF

 

FIREPLACE

 

3.  

PART

 

NUMBER

 

4.  

DESCRIPTION

 

OF

 

PART

 

5.  

FINISH

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

 

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

 

HONOUR

 

THE

 

CLAIM

.

REPLACEMENTS

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

® 

DEALER

.

REPLACEMENT PARTS

ACCESSORIES

GD178 (

WALL

 

TERMINAL

 

KIT

)

24*  W010-1744 

12” FLEX VENT ASSEMBLY

24*  W670-0010 

3”/5” FLEX HORIZONTAL TERMINAL

GD179 (

TERMINAL

 

ONLY

)

25 

W670-0010 

3”/5” FLEX HORIZONTAL TERMINAL

FLEXIBLE VENT KITS

TERMINAL KITS

GDT5 (5 FT)

22*  W730-0031 

3” FLEXIBLE ALUMINUM LINER - (5 

FT

22*  W730-0032 

5” FLEXIBLE ALUMINUM LINER - (5 

FT

)

22* W615-0080 

SPACERS 

(2 

INCLUDED

)

GDT10 (10 FT)

23*  W730-0033 

3” FLEXIBLE ALUMINUM LINER - (10 

FT

)

23*  W730-0034 

5” FLEXIBLE ALUMINUM LINER - (10 

FT

)

23* W615-0080 

SPACERS 

(4 

INCLUDED

)

Summary of Contents for TORCH GT8N

Page 1: ...losion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO I...

Page 2: ...ected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediately call a qualified service technician to inspect the f...

Page 3: ...louring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanical breakage of PHAZER logs and embers nor any venting components used in the installation...

Page 4: ...ace shall be installed on a metal or wood panel extending the full width and depth Purge all gas lines with the glass door of the fireplace open Assure that a continuous gas flow is at the burner befo...

Page 5: ...conjunction with the GD178 wall terminal kit use either the 5 foot vent kit GDT5 or the 10 foot vent kit GDT10 These kits allow for extended horizontal venting of the fireplace The maximum allowable v...

Page 6: ...6 W415 0619 A 08 09 07 N B B G A F C H H L K J M FIGURE 3...

Page 7: ...inished wall surface Apply a heavy bead of the high temperature sealant Slip the vent pipe a minimum of 2 over the inner sleeve of the air terminal and secure with 3 8 screws 3 Using the 5 diameter fl...

Page 8: ...l sheetrock as you would finish any other outside wall of a home This will ensure that clearance to combustibles is maintained within the cavity Proceed once the vent installation is complete Note All...

Page 9: ...ed This fireplace must be electrically connected and grounded in accordance with local codes In the absence of local codes use the current CSAC22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA...

Page 10: ...he top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door out from the retainer along the bottom of the door DOOR REMOVAL FINISHING FIGURE 16 GLASS RE...

Page 11: ...plier s instructions If you cannot reach your gas supplier call the fire department 1 STOP Read the safety information located above 2 Turn off all electric power to the fireplace 3 This fireplace is...

Page 12: ...ear and free of combustible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 Keep the control compartment burner and air sh...

Page 13: ...32 W175 0271 COUPLER KIT Contact your dealer for questions concerning prices and availability of replacement parts Normally all parts can be ordered through your Napoleon dealer or distributor When or...

Page 14: ...Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal venting White grey film forms Sulphur f...

Page 15: ...15 W415 0619 A 08 09 07 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Page 16: ...16 W415 0619 A 08 09 07 NOTES...