W415-2838 / D / 06.22.21
EN
6
general information
Specifications
Emissions
1.30 grams / hour
Efficiency
Overall
LHV
HHV
71.56%
76.99%
71.56%
Chamber (D.W.H)
18” x 23 1/2” x 11”
(457mm x 597mm x 279mm)
Viewing Area
200.6 in² (1294.1cm²)
Capacity
2.51 cubic feet (0.07 cubic meters)
Approx. area heated**
Up to 2,100 ft² (195.1 m²)
Maximum heat output***
70,000 BTU /Hr
Heat output*
19,195 - 54,057 BTU/Hr
Duration low fire**
16.26 hours
Weight w/o bricks
345.78 lbs (156.84kg)
Weight of bricks
48 lbs (21.7kg)
Ideal wood length
Front-back loading
17” (432mm)
Left-right loading
23” (584mm)
Minimum Stack Height ****
15 feet (4.5m)
Efficiency Standard
B415.1-10
Minimum Depth
14 3/8” (365mm)
Maximum Depth
19 1/8” (486mm)
4.4
• Before beginning your installation, consult with your local building code agency or fi re offi cials and insurance
representative to ensure compliance.
• Non-toxic smoke will be emitted during the paint curing process to help dissipate the smoke open a window
near the appliance.
• Remove any dust or debris off the top of the appliance before fi ring the appliance as the paint will become
soft as the appliance heats up and will harden as the appliance cures. To cure the paint on your appliance,
burn your appliance moderately hot during the fi rst few fi res.
• To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door every
5-10 minutes.
• For the fi rst two weeks, use generous amounts of fuel and burn the appliance with the damper wide open
for an hour as the appliance goes through a process of eliminating moisture in the steel and fi rebricks.
The initial heat output will be reduced while the moisture is bring drawn from the appliance and it will be
necessary to build several hot fi res to remove this moisture.
• DURING THIS PROCESS DO NOT OVERFIRE THE APPLIANCE. REDUCE THE AMOUNT OF AIR
COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED.
!
WARNING
• All wiring should be done by a qualified electrician and shall be in compliance with local codes. In the absence of
local codes, use the current CSA 22.1 Canadian Electric Code in Canada or the current National Electric Code
ANSI/NFPA No.70 in the United States.
• This appliance has not been tested with any vented or unvented gas log set. To reduce risk of fire or prevent
injury, do not install a vented or unvented gas log set into the appliance.
• Burning your appliance with the ash dump door open or ajar creates a fire hazard that may result in
discolouration to the gold plated door, internal damage to the appliance or a house chimney fire.
• Do not connect this appliance to a chimney flue serving another appliance.
• This appliance and its components are designed to be installed and operated as a system. Any alteration to
or substition for items in this system, unless allowed by these installation instructions will void the listing and
may void the product warranty. It may also create a hazardous installation. Read through these instructions
thoroughly before starting your installation and follow them carefully through your project.
• Do not install in a mobile home.
1.2 specifications
1.3 general instructions
* As tested using test
method ALT-125.
** Figures will vary consider-
ably with individual condi-
tions.
*** Wolf Steel Ltd. esti-
mated realistic BTU/hr with
hardwood logs and regular
refueling.
**** Required in order to
achieve proper draft.