45
W415-0769 / A / 12.10.10
A.
Remove optional front, see “AFK82/RFK82
FACING KIT INSTALLATION” section.
B.
Tilt the control panel forward and remove
allowing access to the electrode box which is
screwed to the base of the
fi
rebox.
C.
Pull back on the battery compartment door
latch and remove.
D.
Install
battery.
E.
Reinstall battery compartment and control
doors.
11.3 SPARK MODULE BATTERY INSTALLATION
REMOVE 4 SCREWS
BLOWER
MOUNTING PLATE
REMOVE 2 SCREWS
BURNER
BASE
11.4 BLOWER REPLACEMENT
Your
comes equipped with a heat circulating blower. The blower is pre-
wired and is controlled by the remote control supplied with the unit.
Drywall dust will penetrate into the blower bearings, causing irreparable
damage. Care must be taken to prevent drywall dust from coming into contact
with the blower or its compartment. Any damage resulting from this condition
is not covered by the warranty policy.
A.
Turn off the power to the appliance.
B.
Turn off the gas valve.
C.
Remove the glass door, bowl w/rocks, burner, decorative panel, &
burner base.
D.
The blower mounting plate can now be removed. Remove the four
screws that secure the plate to the
fi
rebox base.
E.
The blower is secured to the
fi
rebox. Disconnect the wire
connectors before attempting to remove the blower from the
fi
rebox.
F.
Remove the two screws securing the blower and lift through
blower access opening.
NOTE: When re-installing the replacement blower, it will be necessary to
replace the gasket (W290-0104) on the blower mounting plate.
!
WARNING
BE CAREFUL NOT TO TEAR THE BURNER TRAIN GASKET. A REPLACEMENT GASKET CAN BE
ORDERED FROM YOUR LOCAL AUTHORIZED DEALER.
ELECTRODE BOX
(AA Battery Required)
SEE-TH
RU
W
IN
D
O
W
RECEIVER
ON REMOTE
OFF
W385-0349 / 06.12.07
BURNER
CONTROL
PANEL