HIGH LIMIT SWITCH:
Your appliance is equipped with a high limit switch. In the event that the temperature of
the appliance approaches an unsafe operating temperature, this switch will shut down the pellet feed, which
will eventually shut down the unit. If this happens, it is important to fi nd out why the unit overheated. Contact
your local dealer.
LOW LIMIT SWITCH:
This switch will automatically shut down the appliance if the fi re goes out or fails to light
within 15 minutes.
HOPPER DOOR INTERLOCK:
Your appliance is equipped with a micro switch in the hopper assembly that
shuts-off the auger when the hopper door is opened. Closing the door switches the auger back on, allowing
pellets to feed again.
VACUUM SWITCH:
This switch will sense lack of air fl ow through the appliance and shut down the pellet feed.
This lack of fl ow could be caused by a blocked vent.
POWER FAILURE:
In the event of a power failure, the appliance will shut down. Once power is restored, the
appliance will re-start, unless the convection air temperature has gone above the high limit switch setting. If
this happens, contact your local dealer.
2.4.2 SAFETY FEATURES
2.4.3 EPA COMPLIANCE
We suggest that our pellet hearth
products be installed and serviced by
professionals who are certified in the U.S.
by the National Fireplace Institute
®
(NFI)
as NFI Pellet Specialists or who are
certified in Canada by
Wood Energy Technical
Training (WETT).
www.nficertified.org
66.1A
Summary of Contents for NPS45
Page 48: ...W415 1472 04 21 15 48 EN 67 20 29 58 41 38 43 44 63 57 60 6 11 3 NPI45 REPLACEMENT PARTS...
Page 54: ...W415 1472 04 21 15 54 EN 14 0 SERVICE HISTORY 43 1...
Page 55: ...W415 1472 04 21 15 55 EN 15 0 NOTES 44 1...
Page 106: ...106 W415 1472 04 22 15 FR 67 20 29 58 41 38 43 44 63 57 60 6 11 3 PI CES DE RECHANGE DU NPI45...
Page 114: ...114 W415 1472 04 22 15 FR 15 0 NOTES 44 1...
Page 115: ...115 W415 1472 04 22 15 FR 44 1...