W415-1334 / 06.10.14
46
EN
11.2 CONTROL ACCESS
Once the appliance has been framed and
fi
nished, control access can only be achieved by removing the access
panel inside the
fi
rebox at the right end. The following sub sections take you through the steps of accessing the
control as if the appliance is installed.
*Prior to removing the control panel follow the “DOOR REMOVAL” proccess and then follow the media removal
instructions located under the “MAINTENANCE” section.
NOTE: IT WILL BE NECESSARY TO REPLACE THE GASKET (W290-0197) FOR THE ACCESS PLATE IF
THE UNIT HAS BEEN PREVIOUSLY OPERATED BEFORE REMOVING THE PLATE (W290-0197).
A.
Remove the media tray by removing all screws securing the front, rear and side panels.
B.
Remove the rear right side and then the right side porcelain panels, follow removal instructions under
the “ PORCELAIN PANEL REMOVAL” section.
C.
To access the control access remove the 12 screws securing the access plate.
D.
Care should be taken to ensure avoiding damage to the gasket.
E.
Reverse this process to install the control access. Ensure the access plate is well sealed to the
fi
replace
RIGHT
SIDE
11.3 MEDIA REMOVAL/REPLACEMENT
A. Glass
Insert a clean bag into your vacuum cleaner and vacuum out the glass media.
B. Rock
Carefully remove all of the rocks from the appliance.
C. Driftwood
Carefully remove all of the driftwood logs from the appliance.
D. Sand/Vermiculite
Option 1: Separate and remove the vermiculite from the sand, as best you can, remove it from the appliance.
Insert a clean bag into your vacuum cleaner and vacuum out the sand media.
Option 2: Insert a clean bag into your vacuum cleaner and vacuum out the sand and vermiculite from the
appliance, throw this media away and replace it with a new bag of sand and vermiculite.
37.1C
•
Inspect all accessible gaskets and replace as required.
•
Access the blower, if equipped and clean using a soft brush and vacuum.
•
Re-assemble the various components in reverse order.
•
Inspect the relief system. The appliance relieves through the main glass door or through the
fl
aps on the
fi
rebox top. Ensure they open freely, and close sealed.
•
Check the gas control valve pilot and Hi / Lo knobs move freely (if equipped) – replace if any stiffness in
movement is experienced.
•
Check for gas leaks on all gas connections up and downstream from the gas valve including the pilot tube
connections.