41
W415-0834 / D / 09.07.12
8.3 WIRING
DIAGRAM
69.5
!
WARNING
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.
ON / OFF
SWITCH
ACS/IPI
SWITCH
(OPTIONAL)
DC BACK-UP
GROUND
DFC
VALVE
ORANGE
GREEN
GROUND
EYELET
ON / OFF
IPI / CPI
DISCONNECT THESE
CONNECTORS TO THE
ON/OFF SWITCH AND
CONNECT TO
OPTIONAL
THERMOSTAT .
+
+
-
-
IPI BOARD
DC SUPPLY
TRANSFORMER
VALVE
ELECTRONIC
This appliance comes equipped with a battery back-up. If this backup is used, install 4 AA batteries (not
supplied) into the holder and connect to the wire harness. Place near the IPI board. Connect the battery
holder to the wire harness before using the appliance. Place near the IPI board. If backup is used, it must be
connected to the 6 volt battery pack (supplied).