remove the front lower cover of furnace (wiring schematic located on backside of cover). remove the desired
knockout from the panel and bring the 120v supply conductors through the panel (using electric conductor
feed through connectors and strain reliefs as required by electrical code). route
and secure
the 120v wires to
the door switch junction box located at the front of the furnace.
NOTE
the front door switch junction box can be relocated to the left front corner post if the supply conductors
are brought in through the left side panel.
front loWer Cover
door sWitCh
junCtion boX
THIs FURNACE Is EqUIppED wITH A BLOwER DOOR sAFETY swITCH. DO NOT
DIsABLE THIs swITCH. FAILURE TO FOLLOw THIs wARNINg CAN REsULT IN
ELECTRICAL sHOCk, pERsONAL INjURY, OR LOss OF LIFE.
Warning
!
!