W415-0594 / D / 08.23.11
11
We recommend that the appliance be secured to the fl oor in
all cases.
Using the door opening as a datum, level the appliance by shim-
ming underneath the appliance. Remove and discard the lifting
handles. Bend the tabs down and secure the appliance to the fl oor.
AVERTISSEMEN
T:
AIR COMBURAN
T
SEULEMENT
WARNING:
COMBUSTION
AIR
ONL
Y
WARNING:
BLOWER
CONNECTION ONL
Y
AVERTISSEMENT
:
CONNEXION DE LA
SOUFFLERIE
SEULEMENT
3.1.1 VENTILATION OPENINGS
10' MIN.
TO CHIMNEY CAP.
NOTE: Incorporate a vertical loop or trap into air
liners to reduce air fl ow when appliance is not in
use.
Insulating the intake liners is recommended in colder
climates to prevent condensation from occurring.
The Napoleon Model NZ6000 takes outside air di-
rectly into the appliance through the openings in the
left and right hand sides.
Decide on the most convenient location for the fresh
air inlet ducts and hoods which may be installed
above or below fl oor level.
The fresh air inlet ducts and hoods must be installed.
Secure and seal the intake liners to the collars using
3 sheet metal screws, and high temperature sealant.
The appliance enclosure must be provided with suffi cient air circulation to avoid a fi re hazard. Install ventilation
grilles (minimum openings of 40 sq. inches) at both fl oor and ceiling levels of the enclosure. These grilles must
not restrict the fl ow of heat by more than 25%. Do not install into any area having a height less than 7 feet
(ceiling of enclosure to appliance bottom, excluding hearth height). The location of windows, doors and the
traffi c fl ow in the room where the stove is to be located should be considered. If possible, you should choose a
location where the chimney will pass through the house without cutting a fl oor or roof joist.
3.2 OUTSIDE COMBUSTION AIR