W415-1517 / A / 09.02.16
20
EN
NOTE: When constructing the enclosure allow
for fi nishing material thickness to maintain
clearances.
A minimum of 6" is required to combustibles from the
side of the appliance.
29
1
/
2
”
(749MM)
6”
(152MM)
MIN
6” (152MM)
MIN
54” (1372MM)
42” (1067MM)
75
5
/
16
”
(1913MM)
42” (1067MM)
54” (1372MM)
106
1
/
2
”
(2553MM)
Objects placed in front of the appliance must be kept a minimum of 48" (1219mm) away from the front of the
appliance.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
Framed Enclosure
:
Rear
-
0"
to
stand-offs
Sides
-
6"
(152mm)
Ceiling (Enclosure)
- 84" (2134mm) from the base of the appliance
Ceiling (Room)
- 84" (2134mm) from the base of the appliance
Chimney
- 2" (51mm)
Hot Air Gravity Ductwork Insulation
- 1" (25mm)
5.1
CLEARANCE TO COMBUSTIBLES
5.2
MINIMUM ENCLOSURE CLEARANCES