
EN
W415-1676 / C / 07.23.18
23
framing
5.1 finishing material
NON-COMBUSTIBLE BOARD
COMBUSTIBLE
FACING AND WOOD
FRAMING MAY START
AT 8’ (2.4M) ABOVE
THE BASE OF THE
APPLIANCE.
FACE MUST HAVE A
MIN. 8’ (2.4M) HEIGHT
OF NON-COMBUSTIBLE
BOARD DEPENDING
UPON THE CEILING
HEIGHT
FACEPLATE
MIN. ENCLOSURE
CEILING HEIGHT 96”
(243.8CM).
USE METAL STUDS WHEREVER NON-COMBUSTIBLE
FACING IS REQUIRED
NON-COMBUSTIBLE
BOARD FROM THE SIDE
MEASURED FROM THE
SIDE OF THE FACEPLATE.
46 3/8"
(117.8cm)
MIN. 6"
(152mm)
*
* 7 1/2" (190.5mm) is recommend to meet centre of slip studs.
• Screws used to fasten finishing materials to the face of the appliance above the guillotine screen and door
must not penetrate more than 1/2” (13mm) into the sheet metal front panels. Refer to the “dimensions”
section for specific requirements.
• Do not pack air spaces with insulation or other materials.
• Use only a non-combustible material to finish the face of the appliance. A non-combustible material such
as cement board is required for this purpose.
• Ventilation openings are mandatory for enclosures.
• Above 73 5/8” (187cm) combustible finishing materials may be used on the front face (measured appliance
from base of unit).
• Do not insulate around the appliance.
!
WARNING
Before you completely close up the enclosure, ensure the air control, flue damper and the door / screen
assemblies perform as intended.
note: