installation
3.3.2 installing natural vent
Follow the instructions of the natural vent manufacturer for chimney installation.
A.
Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B.
Replace the four screws per side to secure the rear panel to
the appliance.
C.
Remove the spill switch bracket from the rear of the adapter.
D.
Gently pull the two wire terminals (located inside the
7" (178mm) fl ue collar at the top of the appliance) out
approximately 8" (203mm).
E.
Bring the wires through the lower hole in the adapter and out
the spill switch opening. To pass the wires through the hole
more easily, temporarily tape the two terminals together.
F.
With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance fl ue collar.
G.
Connect the wire terminals to the spill switch and re-secure the
bracket.
H.
Secure the terminal block into place as shown with the screw
supplied.
I.
Unscrew the wire access cover plate from the rear right hand
side below the fi rebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate. Connect
one wire end to the terminal block and the other end to
terminal 1 of the gas valve. Connect the two wires running
down the left side of the appliance from the on/off switch to
the remaining tab on the terminal block and to terminal 3 on
the gas valve.
For aesthetics, the adapter has been
designed to accept a standard matte
black 7" (178mm) stove pipe and the
decorative band (standard with the GS-
150KT). Both are available from your
local authorized dealer / distributor.
3.3.3 natural
vent
Attach the Natural Vent label (see below) in the control area of the appliance.
SWITCH
SPILL
ADAPTER
COMBUSTION AIR COVER
PLATES AND GASKET
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
MODEL.
ATTACHEZ CET ÉTIQUETTE DANS LA RÉGION DE CONTRÔLE DU FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
W385-0160 / B
NO B-VENT ADAPTER
WIRES (GDS28)
TERMINAL BLOCK
WIRE ACCESS
COVER PLATE
3.3.4 combustion
air
This appliance needs air for safe operation and must be installed in such a way that adequate combustion air is
available.
note:
If not converting, the wires are rated for high
temperatures and may remain as is in the