Napoleon GI3016-N Installation And Operation Instructions Manual Download Page 11

11

W415-0171 / E / 01.10.05

3.  Check to see that all burner ports are burning. Clean out
any of the ports which may not be burning or are not burn-
ing properly. (right brick panel must be removed in order to
facilitate burner removal)

4.   Check to see that the pilot flame is large enough to
engulf the thermopile on one leg and reaches toward the
burner on the other leg.

5.  Replace the cleaned logs.

6.  Check to see that the main burner ignites completely on
all openings when the gas knob for the burner is turned
on. A 5 to 10 second total light-up period is satisfactory. If
ignition takes longer, consult your Napoleon dealer / dis-
tributor.

7.  Check that the gasketing on the door is not broken or
missing. Replace if necessary.

TURN OFF THE GAS AND ELECTRICAL POWER

BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when serv-
icing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing.
This insert and its venting system should be inspected
before use and at least annually by a qualified service per-
son. The fireplace area must be kept clear and free of
combustible materials, gasoline or other flammable va-
pours and liquids. The flow of combustion and ventilation
air must not be obstructed.

1.  In order to properly clean the burner and pilot assembly,
remove the logs to expose both assemblies.

2.  Keep the control compartment, logs, burner, air shutter
opening and the area surrounding the logs clean by vacu-
uming or brushing, at least once a year.

FIGURE 21

The Napoleon gas fireplace insert comes standard with a
blower, a heat sensor, variable on/off speed control and a
power cord. Because the blower is thermally activated,
when turned on, it will automatically start approximately 15
minutes after lighting the fireplace and will run for approxi-
mately 30 minutes after the fireplace has been turned off.
Use of the fan increases the output of heat. Air, drawn in
through the lower louvre access door, is driven up the back
of the firebox, and exhausted as hot air between the upper
louvres.

Turn off the gas and electric power to the unit.

Remove the glass door.

Remove the lower glass bracket.

Remove the logs.

Remove the burner assembly. (right brick panel must
be removed in order to facilitate removal)

Remove the four screws holding the access door in
place on the control assembly (located to the back of
the burner assembly.) For location, see picture in re-
placement parts.

Disconnect the electrical connectors at the blower.

Remove the blower.

FIGURE 23

1.  Remove the pilot adjustment cap.

2.  Adjust the pilot screw to provide properly sized flame.

3.  Replace the pilot adjustment cap.

Natural gas models have air shutters set at 1/16 (.063")
inch open. Propane gas models have air shutters set at  [5/
16] (.313) inch open. Closing the air shutter will cause a
more yellow flame, but can lead to carboning. Opening the
air shutter will cause a more blue flame, but can cause
flame lifting from the burner ports. The flame may not ap-
pear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A

QUALIFIED GAS INSTALLER!

PILOT ASSEMBLY

FIGURE 25

PILOT ADJUSTMENT

CAP

FLAME MUST ENVELOP UPPER

3

/

16

" TO ½" OF THERMOPILE

THERMOPILE

Drywall dust will penetrate into blower bearings causing irrepairable damage and must be prevented from coming into
contact with the blower or its compartment.
Any damage resulting from this condition is not covered by the warranty policy.

MAINTENANCE

BLOWER REPLACEMENT INSTALLATION

BLOWER  SYSTEM

BLOWER REPLACEMENT INSTRUCTIONS

ADJUSTMENTS

PILOT  BURNER  ADJUSTMENT

VENTURI  ADJUSTMENT

FIGURE 24

Summary of Contents for GI3016-N

Page 1: ...e vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Page 2: ... vapours and liquids Do not use this fireplace if any part has been under water Immediately call a qualified service techni cian to inspect the fireplace and to replace any part of the control system and any gas control which has been under water Under no circumstances should this fireplace be modified Do not burn wood or other materials in this fire place Adults and especially children should be ...

Page 3: ...uires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON are based on a predetermined rate schedule and any repair are based on a predetermined rate schedule and any repair are based on a predetermined rate schedule and any repair are based on a pred...

Page 4: ... log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts In absence of local code...

Page 5: ... non combustible materials If necessary have any repair work done by a qualified person before installing the in sert Remove the existing fireplace damper or lock into an open position Using screws attach the fireplace warning tag W385 0199 to the inside of the firebox of the fireplace into which the insert is being installed The sheet metal parts of the fireplace in which the gas fireplace insert...

Page 6: ...y again If the smoke or flame is still not drawn into the spill tube turn the unit off and check for adequate fresh air supply vent blockage or restriction If necessary consult with a qualified inspector SPILL SWITCH VENTING ACTION CHECK Levelling the insert will eliminate rocking or excessive noise when the fan is in operation Replace the securing screw to the front of the dilution plate Install ...

Page 7: ...harcoal embers available from your Napoleon dealer 1 Place the front log onto the main burner pushing it as close as possible to the burner ports without blocking covering them The left and right spacing between the log ends and the burner ports should be equal 2 Place the back log onto the log support brackets located on the rear wall of the combustion chamber The notch situated at the lower left...

Page 8: ...king of the logo supplied and place on the glass viewing area as indicated LOWER GLASS BRACKET LOGO 11 8 13 8 SECURING SCREW LOCATIONS LOGO PLACEMENT FLUSH GLASS FRONT KIT GI FF FLASHING SURROUND KITS GI 900 GI 909 UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips LOWER LOUVRES Secure the lower louvre assembly to the insert using the 4 screws supplied FLUSH LOUVRE ...

Page 9: ...re the bay to the insert front at the top and bottom outside corners using 4 screws Note Black louvre assembly if supplied must be installed as uppers due to the high fireplace temperature Assemble the flashing and mount to the inside of the outer shell using 4 securing screws and spacers supplied as shown Hook the ornamental inlays over the spacers Both these options may be attached to the insert...

Page 10: ...r turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de partment Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building 8 Depress and hol...

Page 11: ...l automatically start approximately 15 minutes after lighting the fireplace and will run for approxi mately 30 minutes after the fireplace has been turned off Use of the fan increases the output of heat Air drawn in through the lower louvre access door is driven up the back of the firebox and exhausted as hot air between the upper louvres Turn off the gas and electric power to the unit Remove the ...

Page 12: ...S C W LOWER DOOR TRIM 31 GIB OIG GOLD PLATED BAY ORNAMENTAL INSETS 32 GI 778KT BRICK PANEL KIT 33 W470 0002 ENAMEL TOUCH UP AND BRUSH SPECIFY COLOUR 34 GI 700KT ZERO CLEARANCE SHELL 35 111 KT OUTSIDE AIR KIT 36 W690 0001 MILLIVOLTTHERMOSTAT 37 W660 0011 REMOTE CONTROL ADVANTAGE PLUS 38 GD 660 WALL SWITCH 20FT WIRE 39 W500 0033 V S S MOUNTING PLATE FOR WALL SWITCH 40 GI 900AB6 ANTIQUE BRASS FLASHIN...

Page 13: ...13 W415 0171 E 01 10 05 ...

Page 14: ...hts replace the wall switch B Wall switch wiring is defec tive disconnect switch wires from valve and connect a jumper wire across terminals 1 and 3 if the main burner lights check the wires for defects and or replace wires C Main burner orifice is plugged remove stoppage in orifice D Remote gas valve operator is defective connect a jumper wire across terminals 1 and 3 if main burner does not ligh...

Page 15: ...ed in room head aches check for chimney blockage check that chimney is installed to building code room is in negative pressure increase fresh air supply Fireplace is spilling A Wall switch is mounted up side down B Remote wall switch is grounding C Remote wall switch wire is grounding Remote wall switch is in off position main burner comes on when gas knob is turned to ON posi tion reverse replace...

Page 16: ...16 W415 0171 E 01 10 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name ...

Reviews: