7.4.2 EXTENDED FIRE
7.5 SMOKING
82.1
Load your larger pieces of wood compactly, packed close enough to prevent the fl ames from penetrating it
completely. After approximately 30 minutes, depending on the size of the load, close the draft control complete-
ly making sure that the fi re is not extinguished.
DO NOT OVERFIRE THE APPLIANCE!
Overfi ring can occur by:
A.
Burning large amounts of smaller wood pieces such as furniture scraps, skids or treated wood;
B.
Vigorously burning large loads of wood with the draft control on “HIGH” (fully open) for long periods of
time (one or two hours).
C.
Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door.
83.1
A properly installed appliance should not smoke. If yours does, check the following:
•
Has the chimney had time to get hot?
•
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
•
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
•
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
•
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?