background image

:ROI6WHHO/WG1DSROHRQ5G%DUULH21/0<&DQDGD ‡  ‡ ID[ ‡ ZZZQDSROHRQILUHSODFHVFRP

ADJUSTMENTS

VENTURI ADJUSTMENT

Air shutter adjustment must be done by a qualifi ed 

installer!

All models have air shutters that have been factory set open 
according to the chart below:
These setting are for (maximum) horizontal termination.

Adjustment may be required depending on fuel type, vent 
confi guration and altitude.

Closing the air shutter will cause a more yellow fl ame, but 
can lead to carboning.  Opening the air shutter will cause a 
more blue fl ame, but can cause fl ame lifting from the burner 
ports.  The fl ame may not appear yellow immediately; allow 
15 to 30 minutes for the fi nal fl ame colour to be established. 

BGD/BCDV36

BGD/BCDV36CF BGNV/BCNV36

NG

1

/

16

1

/

16

1

/

16

LP

1

/

4

1

/

4

3

/

8

Adjust the pilot screw to provide properly sized fl ame.  Turn 
in a clockwise direction to reduce gas fl ow.

Inlet pressure can be checked by turning screw (A) counter-
clockwise until loosened and then placing pressure gauge 
tubing over the test point. Gauge should read 7” (minimum 4.5”) 
water column for natural gas or 13” (11” minimum) water column 
for propane. Check that main burner is operating on “HI”.

Outlet pressure can be checked the same as above using 
screw (B). Gauge should read 3.5” water column for natural 
gas or 10” water column for propane. Check that main burner 
is operating on “HI”.

AFTER TAKING PRESSURE READINGS, TIGHTEN 
SCREWS FIRMLY TO SEAL. DO NOT OVERTORQUE.

LEAK TEST

3/8” - 1/2”

FLAME MUST 

ENVELOPE UPPER 

3/8" TO 1/2" OF

THERMOCOUPLE & 

THERMOPILE

It is important to 
periodically perform 
a visual check of the 
pilot and burner fl ames.  
Compare them to the 
illustrations provided.

Maximum Input Ratings

BGD/BCDV36

BGD/

BCDV36CF

BGNV/BCNV36

NG

18,000 BTU/hr

17,000 BTU/hr

17,000 BTU/hr

LP

17,000 BTU/hr

17,000 BTU/hr

17,000 BTU/hr

To access the air shutter, remove the two screws that secure 
the cover to the air housing, taking care not to damage the 
gasket.

PILOT 

BURNER

THERMOCOUPLE

THERMOPILE

P

I

PILOT

N

O

L

O

T

H

I

L O

F

F O

A

B

PILOT SCREW

PILOT BURNER ADJUSTMENT

VENTURI

AIR SHUTTER 
OPENING

ORIFICE

Reviews: