General Information

This Gas Barbecue is certified under Canadian and American National Standards, CSA 1.6-2015 

and 

ANSI 

Z21.58-2015 respectively for Outdoor Gas Grills and should be installed to conform according to local 

codes. In absence of local codes, install to the current CAN B149.1 Natural Gas and Propane Installation 

Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.  
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence 

of local codes, with the current CSA C22.1 

Canadian Electrical Code in Canada or the National Electrical 

Code, 

ANSI/NFPA 70

 in the United States.

WARNING

: This product can expose you to chemicals including lead and lead compounds, which are 

known to the State of California to cause cancer, and chemicals including di-n-butyl phthalate, which are 

known to the State of California to cause birth defects or other reproductive harm. For more information 

go to 

www.P65Warnings.ca.gov

.

Propane Cylinder Specifications

WARNING!

 If these instructions are not followed exactly, a fire causing death or serious 

injury may

occur.

WARNING!

 Do not store a spare propane cylinder on the shelf beneath the barbecue.

If the gas grill is being supplied with propane from a portable cylinder, a regulator specified by the 

manufacturer must be used.  The regulator must supply a pressure of 11 inches water column (0.39 PSI) to 

the gas grill and have a QCC1 type fitting. Cylinders to be used with this unit must be supplied with a QCC1 

cylinder valve.  A QCC1 cylinder has a positive seating connection, which will not allow gas flow until a 

positive seal has been achieved.  It is also equipped with an excess flow device.  In order to attain full flow 

to the grill, the valves must be in the off position when the cylinder valve is turned on.  

A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never 

use a cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in 

accordance with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/CSA-b339, 

Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or 

the Specifications for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). Cart models have 

been designed for use with a 20 lb (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the connection 

for outdoor cooking appliances.

  

The propane cylinder must be provided with a shut-off valve terminating 

in a propane cylinder valve type QCC1, and a safety relief device having direct communication with the 

vapor space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the 

cylinder shall include a collar to protect the cylinder valve.  The cylinder shall incorporate a listed OPD 

(overfill protection device).  Do not store a spare LP-gas cylinder under or near this appliance. Never fill 

the cylinder beyond 80 percent full.  If the preceding information is not followed exactly, a fire causing 

death or serious injury may occur.

NOTE!

 Propane regulator hose not included.

Gas Hook-Up Instructions

WARNING!

 This grill is designed for non-combustible enclosures only, and must be installed and

serviced by a qualified installer to local codes.

WARNING!

 Cabinet frame, cabinet, and counter top must be made from non-combustible

material.

WARNING!

 As indicated on the rating plate, this gas grill is designed to operate with gas supply

pressures of 11” WC for Propane and 7” WC for Natural Gas.  For installations where the gas supply 

pressure exceeds these requirements, a regulator must be installed upstream of the grill’s components.  

If the gas supply pressure is lower than these requirements, the unit will be under-fired and will not 

reach the maximum temperatures.  Ensure that the supply line size complies with local and/or national 

installation codes.

BUILT IN PROPANE GAS HOOK-UP

: The piping up to the gas grill is the responsibility of the installer and 

piping should be located as shown in the built-in instructions.  A flexible metal connector is included to 

simplify the installation of the unit.  Connect this flexible metal connector to the flare fitting on the end of 

the manifold.  Connect the other end of the connector to the gas piping.  Ensure that the connector does 

not pass through a wall, floor, ceiling or partition, and is protected from damage.  Do not use a hose to 

!

!

!

!

N415-0542 DEC 11.18.indd   4

12/13/2018   11:03:48 AM

Summary of Contents for BIPRO665-3

Page 1: ...r continues keep away from the appliance and immediately call your gas supplier or fire department APPLY SERIAL NUMBER LABEL FROM CARTON Serial No XXXXXX000000 MODEL NO This gas grill must be used onl...

Page 2: ...ial or indirect damages or for any transportation charges labor costs or export duties This Limited Warranty is provided in addition to any rights afforded to you by local laws Accordingly this Limite...

Page 3: ...other enclosed area Natural gas units must be disconnected from the supply when being stored indoors Inspect the fuel supply hose before each use If there is evidence of excessive abrasion or wear or...

Page 4: ...r Transportation of Dangerous Goods and Commission as applicable or the Specifications for LP Gas Cylinders of the U S Department of Transportation D O T Cart models have been designed for use with a...

Page 5: ...than 20 in2 130 cm2 for a 20 lb 9 1 kg cylinder and 30 in2 195 cm2 for a 30 lb 13 6 kg cylinder 2 At least one ventilation opening on the exposed exterior side of the enclosure located 1 in 25 4 mm or...

Page 6: ...flexible metal connector is included to simplify the installation of the unit Connect this connector to the flare fitting on the end of the manifold Connect the other end of the connector to the gas p...

Page 7: ...onds turn the control knob to the off position and wait 5 minutes for any excess gas to dissipate Either repeat steps 2 and 3 or light with a match 4 If the burner will not ignite within 5 seconds tur...

Page 8: ...winds adversely affect the cooking performance of the gas grill In extreme circumstances when consistent high winds come from directly behind the unit heat can vent underneath the control panel This...

Page 9: ...r on the inside For example a 3 pound chicken on the rotisserie will be done in approximately 1 hours on medium to high Search Grill Master Recipes at www napoleongrills com recipes for rotisserie ATT...

Page 10: ...Cleaning Inside The Gas Grill Remove the cooking grids Use a brass wire brush to clean loose debris from the casting sides and underneath the lid Scrape the sear plates with a putty knife or scraper a...

Page 11: ...Remove cooking grids and sear plates and leave lid open You may have to open the door or remove the top drawer if equipped to access the air shutter screw located at the mouth of the burner The back c...

Page 12: ...other debris Reinstallation Reverse the procedure to reinstall the burner Check that the valve enters the burner when installing Replace sear plate mount and or tighten screws to complete reinstallati...

Page 13: ...sing parts please call our Customer Solutions Department at 1 866 820 8686 between 9 AM and 5 PM Eastern Standard Time CAUTION During unpacking and assembly we recommended you wear work gloves and saf...

Page 14: ...terials to the appliance Do not use wood or drywall W W H D W H D 1 44mm BUILT IN SIDEBURNER GAS INLET OPENING NON COMBUSTIBLE MATERIAL OUTDOOR GFI ELECTRICAL OUTLET RECOMMENDED LOCATE ON SAME SIDE OF...

Page 15: ...18 EN www napoleongrills com N415 0542 DEC 11 18 APPLY A DAB OF SILICONE TO EACH FLANGE TO SECURE IN PLACE N415 0542 DEC 11 18 indd 18 12 13 2018 11 04 06 AM...

Page 16: ...19 www napoleongrills com N415 0542 DEC 11 18 N415 0542 DEC 11 18 indd 19 12 13 2018 11 04 06 AM...

Page 17: ...below the bottom of the grill as illustrated Fasten the electrical box to the inside of the enclosure making sure the ventilation holes are not obstructed Plug the power supply into a Ground Fault Int...

Page 18: ...21 www napoleongrills com N415 0542 DEC 11 18 x1 x1 x1 NON METALIC CABINET ONLY 4 3 5 LOCATED INSIDE CABINET N415 0542 DEC 11 18 indd 21 12 13 2018 11 04 14 AM...

Page 19: ...22 EN www napoleongrills com N415 0542 DEC 11 18 COUNTER TOP REQD NOT INCLUDED IM UGC665 N415 0542 DEC 11 18 indd 22 12 13 2018 11 04 17 AM...

Page 20: ...23 www napoleongrills com N415 0542 DEC 11 18 N570 0038 1 4 20 X 1 2 x2 N450 0008 1 4 20 x2 IM UGC665 1 2 3 4 N415 0542 DEC 11 18 indd 23 12 13 2018 11 04 19 AM...

Page 21: ...24 EN www napoleongrills com N415 0542 DEC 11 18 x1 x1 x2 x1 5 LOCATED INSIDE CABINET 6 7 N415 0542 DEC 11 18 indd 24 12 13 2018 11 04 23 AM...

Page 22: ...25 www napoleongrills com N415 0542 DEC 11 18 3 1 2 N415 0542 DEC 11 18 indd 25 12 13 2018 11 04 24 AM...

Page 23: ...26 EN www napoleongrills com N415 0542 DEC 11 18 N415 0542 DEC 11 18 indd 26 12 13 2018 11 04 26 AM...

Page 24: ...erforming this test and remove all sources of ignition See Leak Testing Diagram for areas to check Turn all burner controls to the off position Turn gas supply valve on Brush a half and half solution...

Page 25: ...m N415 0542 DEC 11 18 Rotisserie Kit Assembly Instruction optional Assemble rotisserie kit components as shown X Ensure stop bushing is tightened on the inside of hood casting N415 0542 DEC 11 18 indd...

Reviews: