INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be elec-
trically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 C
ANADIAN
ELECTRICAL
CODE
in Canada or the
ANSI/NFPA 70
NATIONAL
ELECTRICAL
CODE
in the United States.
Remove the blower from its mounting bracket and attach to the bracket supplied with
the appliance. This bracket is found secured on the mounting stud located at the bot-
tom of the vent side wall. The blower bracket contains two holes that allow the blower
to be positioned away from the intended gas supply hole.
Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole into
the pad. The blower must be able to be positioned entirely onto the pad.
Tilt the blower onto its side and slide it
past the controls. Position the blower
under the clip and onto the stud. Secure
with a wing nut.
Remove the "Z" shaped mounting bracket
secured to the burner, by the pilot. Re-
move the thermal switch from the bracket supplied in the blower kit and attach to
the mounting bracket. Attach the connectors from the black and white wires to the
thermal switch. Replace bracket and switch in the location it was removed from.
Do not overtighten thermal switch or distort housing. Attach the connectors from
the black and red wires to the blower. Attach and secure the variable speed
switch using the nut provided. Plug the harness cord into the receptacle.
The wire harness provided in this kit is a universal harness. When installed,
ensure that any excess wire is contained, preventing it from making
contact with moving or hot objects.
Drywall dust will penetrate into the blower bearings, causing irrepara-
ble damage. Care must be taken to prevent drywall dust from coming
into contact with the blower or its compartment. Any damage resulting
from this condition is not covered by the warranty policy.
Because the blower is thermally activated, when turned on, it will au-
tomatically start approximately 10 minutes after lighting the appliance
and will run for approximately 30 - 45 minutes after the appliance has been turned off. Use of the
fan increases the output of heat.
51.4A
black
white
red
BLOWER
THERMAL
SWITCH
VARIABLE
SPEED
SWITCH
MOUNTING
BRACKET
8.0 ELECTRICAL CONNECTION
!
WARNING
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED
SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
ELECTRICAL CIRCUIT.
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THE UNITED STATES.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.