It’s important to periodically perform a visual check of the pilot and 
burner 

fl

 ames. Compare them to the illustrations provided. If any 

fl

 ames 

appear abnormal call a service person.

54.2A

3/8” - 1/2”

FLAME MUST 

ENVELOP UPPER 

3/8" TO 1/2" 

(12.7mm - 9.5mm) OF

THERMOCOUPLE & 

THERMOPILE

(9.5mm - 12.7mm)

9.3 FLAME 

CHARACTERISTICS

10.0 MAINTENANCE

CAUTION:

 Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper 

and dangerous operation. Verify proper operation after servicing. This appliance and its venting system 
should be inspected before use and at least annually by a quali

fi

 ed service person. The appliance area must 

be kept clear and free of combustible materials, gasoline or other 

fl

 ammable vapors and liquids. The 

fl

 ow of 

combustion and ventilation air must not be obstructed.

A.

 

In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to 
expose both assemblies.

B.

 

Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs 
clean by vacuuming or brushing, at least once a year.

C.

 

Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or 
are not burning properly. 

D. 

Check to see that the pilot 

fl

 ame is large enough to engulf the 

fl

 ame sensor and/or thermocouple / 

thermopile as well as reaches the burner.

E.

 

Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning 
which can be distributed in the surrounding living area.

F.

 

Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10 
second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer / 
distributor.

G.

 

Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if 
necessary.

H.

 

If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions 
provided for the initial installation.

I.

  

Cleaning the safety barrier may be necessary due to excessive lint / dust from carpeting, pets, etc. 
simply vacuum using the brush attachment.

J.

  

Ensure the pressure relief system performs effectively. Check that the gasket is not worn or damaged. 
Replace if necessary.

40.1D

MAINTENANCE

MAINTENANCE

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

DO NOT PAINT THE PILOT ASSEMBLY.

!

WARNING

MILLIVOLT 

ILLUSTRATED

Summary of Contents for B30NTR

Page 1: ...trical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fi...

Page 2: ...28 4 3 2 VERTICAL AIR TERMINAL INSTALLATION 29 4 3 3 RESTRICTING VERTICAL VENTS 29 4 4 VERTICAL THROUGH EXISTING CHIMNEY 30 4 5 MOBILE HOME INSTALLATION 31 4 6 GAS INSTALLATION 32 4 7 OPTIONAL WALL SW...

Page 3: ...ection NON COMBUSTIBLE FINISHING Side Wall See the section FRAMING See the section VENTING and INSTALLATION See the section RATING PLATE INFORMATION SAFETY BARRIER Batteries must be disposed of accord...

Page 4: ...no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part has...

Page 5: ...415 1397 09 30 14 EN 34 1 16 866mm GAS INLET B30 ILLUSTRATED 14 355mm 6 11 16 170mm 1 15 16 50mm 30 762mm 12 3 4 324mm 4 102mm 178mm 7 24 3 16 614mm 34 1 2 876mm 8 5 8 136mm SAFETY BARRIER 2 1 DIMENSI...

Page 6: ...uld choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material othe...

Page 7: ...eration Expansion contraction noises during heating up and cooling down cycles are normal and are to be expected A barrier designed to reduce the risk of burns from the hot viewing glass is provided w...

Page 8: ...S PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE AVERTISSEMENT CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE ACTION RAPIDE REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE ACTION RAPIDE DE WOLF STEEL L...

Page 9: ...t pipe shield or attic insulation shield when penetrating interior walls floor or ceiling NOTE If for any reason the vent air intake system is disassembled reinstall per the instructions provided for...

Page 10: ...separately When using Wolf Steel venting components use only approved Wolf Steel rigid flexible components with the following termination kits wall terminal kit GD222 GD222R or 1 12 to 7 12 pitch roo...

Page 11: ...415 1397 09 30 14 EN 3 2 TYPICAL VENT INSTALLATION 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM 34 1 16 865MM TOP VENT 8 203MM MINIMUM 34 1 16 865MM 42 1 16 1068MM MINIMUM PLUS RISE 24 610MM MAX...

Page 12: ...12 W415 1397 09 30 14 EN See VENTING section REAR VENT 40 FT 12M MAXIMUM 3 FT 1M MINIMUM 24 3 16 614MM 16 406MM MINIMUM 20 508MM MAX 24 3 16 614MM PLUS RISE...

Page 13: ...a minimum 12 304 8mm above grade The maximum allowable vent length is 10 3 1m for a fireplace and 8 2 4m for a stove 9 4A 12 305MM MINIMUM TO GRADE 30 762MM MINIMUM 30 762MM MINIMUM 34 1 16 865MM 20 5...

Page 14: ...6mm 16 406mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m See...

Page 15: ...the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 13 2A REAR EXIT Horizontal Termination Vertical Termination Vertica...

Page 16: ...horizontal vent lengths Hr and offsets Ho in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 90 in feet VT combined vertical vent lengths in feet 3 7 ELBOW...

Page 17: ...90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 6m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m Formula 1 HT VT 9 9 FT 3m 11 FT 3 4m Formula 2 HT VT 40 FT 12 2m 20 9 FT 6 4m 40 FT 12 2m Since both f...

Page 18: ...formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT 90 V1 H1 H2 90 Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4 FT 1 2...

Page 19: ...ithin the lines represents acceptable values for HT and HT HT VT 16 3A For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12...

Page 20: ...3_2B For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT 3 5VT Formula 2 HT VT 24 75 feet 7 5m Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4FT 1 2m 1...

Page 21: ...nt configurations requiring one or more 90 elbows top exit or one or more 90 elbows rear exit the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 5 FT 1 5m V2 6 FT 1...

Page 22: ...mulas apply Formula 1 HT 3 VT Formula 2 HT VT 40 feet 12 2m Example V1 2 FT 0 6m V2 1 FT 0 3m V3 1 5 FT 0 5m VT V1 V2 V3 2FT 0 6m 1FT 0 3m 1 5FT 0 5m 4 5 FT 1 4m H1 6 FT 1 8m H2 2 FT 0 6m HR H1 H2 6FT...

Page 23: ...Before attaching an elbow or rigid adaptor to the rear collar it may be necessary to trim the 4 102mm collar WARNING FAILURE TO INSTALL THE CAP WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN...

Page 24: ...AS AND ELECTRICAL SUPPLY TO THE APPLIANCE FOR SAFE AND PROPER OPERATION OF THE APPLIANCE FOLLOW THE VENTING INSTRUCTIONS EXACTLY ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING...

Page 25: ...is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will...

Page 26: ...he additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent pipe...

Page 27: ...ving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is...

Page 28: ...ll Pac 25 1A 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION A Move the appliance into position Measure the vent length required between terminal and appliance taking into account the additional length nee...

Page 29: ...g a 3 4 19 1mm margin all around Fasten to the roof Do NOT nail through the lower portion of the flashing Make weather tight by sealing with caulking Where possible cover the sides and top edges of th...

Page 30: ...ectly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the preferred manufacturer s appliance adaptor has be...

Page 31: ...ding products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is recommended that the applian...

Page 32: ...PE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFOR...

Page 33: ...SURE INSULATION AND OTHER MATERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO MAINTAIN CLEARANCES FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS LI...

Page 34: ...34 W415 1397 09 30 14 EN 5 7 1 MINIMUM FRAMING DIMENSIONS 301 2 775mm 343 4 883mm 115 16 49mm 71 2 192mm 141 2 368mm GAS INLET LOCATION ELECTRICAL CONNECTION ENCLOSURE TOP FINISHING MATERIAL...

Page 35: ...rial brick stone or ceramic tile may protrude in these areas Minimum clearance to combustible construction from appliance and vent surfaces Combustible Framing 0 to stand offs 1 25mm to bottom and sid...

Page 36: ...CK ANDSTONE 3 76mm MINIMUM 3 76mm 2 51mm 1 25mm 1 25mm 501 2 1283mm 54 1372mm CEILING MIN 141 2 368mm 421 16 1068mm MINIMUM PLUSRISE 161 4 412mm TOP EXIT ENCLOSURE The appliance requires a minimum non...

Page 37: ...GISUSED SUCHASBRICK ANDSTONE 3 76mm 1 25mm 243 16 614mm MINIMUM PLUSRISE 1 25mm 36 914mm 17 8 48mm 54 1372mm REAR EXIT ENCLOSURE The appliance requires a minimum non combustible enclosure height of 36...

Page 38: ...o combustibles are maintained Non combustible material can be used provided the minimum clearances to combustible materials are applied The minimum enclosure volume must be increased by no less than t...

Page 39: ...rojections are desired increase the clearance to the sides and top by 2 51mm for every additional 1 25mm of projection If using an optional surround the same rule applies starting from the top of the...

Page 40: ...02mm 6 152mm WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT ENSURE ALL C...

Page 41: ...th two latches along the top and two along the bottom Pull the handles of the latches forward then lift the latches out from the door frame to release the top of the door Repeat the same step for the...

Page 42: ...colours will become more uniform as colour pigments burn in during the heat activated curing process A Place the rear log W135 0575 firmly onto the two studs at the rear of the support tray Ensure the...

Page 43: ...EMENT 97 1A Remove the backing of the logo supplied and place on the glass viewing door as indicated 12 7mm LOGO 12 7mm E Place the right crossover log W135 0579 onto the two remaining pins B A C D E...

Page 44: ...ance to the battery housing F Place the battery housing into the control compartment ensure that the battery housing is placed in a clean and easily accessible location G Reinstall the safety screen T...

Page 45: ...gure 1 I Remove the adhesive backing strip from the velcro strip located on the variable speed switch VSS Place the VSS firmly into position on the front left corner of the base of the outer shell ref...

Page 46: ...CT THESE CONNECTIONS TO THE ON OFF SWITCH AND CONNECT TO AN OPTIONAL THERMOSTAT IPI BOARD DC SUPPLY TRANSFORMER VALVE ELECTRONIC OFF ON This appliance comes equipped with a battery back up If this bac...

Page 47: ...n off all gas to the fireplace Open windows Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbour...

Page 48: ...t until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is depres...

Page 49: ...or 3 turns and then placing pressure gauge tubing over the test point Gauge should read as described on the chart below Check that main burner is operating on HI Outlet pressure can be checked the sa...

Page 50: ...the ports which may not be burning or are not burning properly D Check to see that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as well as reaches the bur...

Page 51: ...ting inspection and inspection of the burner media and firebox Refer to the door removal section and remove the door as instructed Carefully remove media if necessary logs glass brick panels etc Using...

Page 52: ...ommended fireplace glass cleaner Thereafter clean as required If the glass is not kept clean permanent discoloration and or blemishes may result HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COO...

Page 53: ...ve the following information Model Serial Number of appliance Installation date of appliance Part number Description of part Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION C...

Page 54: ...FETY BARRIER ASSEMBLY W010 3244 DOOR ASSEMBLY W010 3446 ELECTRONIC VALVE TRAIN ASSEMBLY W010 3267 MILLIVOLT VALVE TRAIN ASSEMBLY W715 0976 TOP FINISHING TRIM W335 0067 HOOD RIGHT CROSSOVER LOG GL 694...

Page 55: ...RNER ORIFICE 49 NG W100 0162 BURNER ASSEMBLY 26 25 W725 0025 VALVE NG STOCKED STOCKED YES 14 14 14 14 14 33 14 34 14 14 14 14 14 14 W680 0005 THERMOCOUPLE W680 0004 THERMOPILE W010 0800 PILOT LP W010...

Page 56: ...MANIFOLD FLEX PIPE B30 ELECTRONIC VALVE TRAIN ASSEMBLY ITEMS MAY NOT APPEAR EXACTLY AS ILLUSTRATED 10 03 14 W010 1986 WIRE ASSEMBLY W290 0248 VALVE TRAIN GASKET YES 14 46 14 14 14 14 14 14 14 W190 002...

Page 57: ...EL PRPB30 W475 0939 W475 0940 16 W690 0002 THERMODISC AUB W062 0059 BLOWER AUB 72 73 4 67 5 69 70 71 74 75 76 77 AUB ACSENT UNIVERSAL BLOWER KIT W430 0003 MAGNETS X16 TK30 TOP BOTTOM TRIM X2 TK30 SIDE...

Page 58: ...ed and plugged into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer ar...

Page 59: ...e rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood the...

Page 60: ...or plate See RESTRICTING VENTS section if applicable Main burner flame is a blue lazy transparent flame Blockage in vent Remove blockage In really cold conditions ice buildup may occur on the terminal...

Page 61: ...lace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch termin...

Page 62: ...Gauge should read as described on the chart below Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak tes...

Page 63: ...headaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative...

Page 64: ...damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single claim During the first 10 y...

Page 65: ...65 W415 1397 09 30 14 EN 43 1 20 0 SERVICE HISTORY...

Page 66: ...66 W415 1397 09 30 14 EN 44 1 21 0 NOTES...

Page 67: ...67 W415 1397 09 30 14 EN 44 1...

Page 68: ...ces Outdoor Fireplaces Gourmet Grills Fireplaces Heating Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie...

Page 69: ...L installation et l entretien doivent tre faits par un installateur qualifi une agence d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j instal e dem...

Page 70: ...MINAISON HORIZONTALE 96 4 3 2 INSTALLATION DE LA TERMINAISON VERTICALE 97 4 3 3 RESTREIGNANT DES VENTS VERTICAUX 97 4 4 TERMINAISON VERTICALE TRAVERS UNE CHEMIN E EXISTANTE 98 4 5 INSTALLATION DANS UN...

Page 71: ...MAT RIAU DE FINITION INCOMBUSTIBLE Mur lat ral Voir la section OSSATURE Voir les sections VACUATION et INSTALLATION Voir la section INSTALLATION DES PERSIENNES CRAN DE PROTECTION Les piles doivent tre...

Page 72: ...ntretien Un entretien plus fr quent pourrait tre n cessaire en raison des peluches provenant des tapis literie etc L emplacement de l appareil doit tre gard libre de tous mat riaux combustibles essenc...

Page 73: ...10 01 14 FR 2 1 DIMENSIONS 34 1 16 866mm GAZ DU ENTR E B30 ILLUSTR 14 355mm 6 11 16 170mm 1 15 16 50mm 30 762mm 12 3 4 324mm 4 102mm 178mm 7 24 3 16 614mm 34 1 2 876mm 8 5 8 136mm CRAN DE PROTECTION E...

Page 74: ...cher ou de toit Si l appareil est install directement sur un tapis sur une surface de vinyle ou tout autre rev tement de plancher combustible autre que le bois l appareil devra tre mont sur un panneau...

Page 75: ...olt fonc tionnement du syst me Les bruits caus s par l expansion et la contraction lors des cycles de chauffage et de refroidissement sont tout fait normaux et il faut s y attendre Une barri re con u...

Page 76: ...T WITH THE FLAMES OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES TOP DESSUS 0 RECESSED DEPTH...

Page 77: ...es murs int rieurs le plancher ou le plafond sont travers s NOTE Si pour une raison quelconque le syst me d vents de prise d air est d mont r installez le selon les instructions fournies dans l instal...

Page 78: ...n suivants les ensembles de terminaison murale GD222 GD222R ou l ensemble de terminaison pour toit de pente 1 12 7 12 GD110 l ensemble de terminaison pour toit de pente 8 12 12 12 GD111 l ensemble de...

Page 79: ...01 14 FR 3 2 INSTALLATIONS TYPIQUES D VENTS VACUATION SUR LE DESSUS 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM 34 1 16 865MM 8 203MM MINIMUM 34 1 16 865MM 42 1 16 1068MM MINIMUM PLUS LA PENTE...

Page 80: ...80 W415 1397 10 01 14 FR Voir la section VACUATION 40 FT 12M MAXIMUM 3 FT 1M MINIMUM 24 3 16 614MM 16 406MM MINIMUM 20 508MM MAX 24 3 16 614MM PLUS LA PENTE VACUATION SUR L ARRI RE...

Page 81: ...12 305MM MINIMUM AU NIVEAU DU SOL 12 305MM MINIMUM TO GRADE 30 762MM MINIMUM 30 762MM MINIMUM 34 1 16 865MM 3 3 2 INSTALLATION EN COIN Lorsque l vent est install en coin la longueur maximale du condu...

Page 82: ...combustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1 8m Voir le tableau pour les dimensions d un mur plus profond La terminaison ne doit...

Page 83: ...ourse verticale plus grande ou gale la course horizontale 83 W415 1397 10 01 14 FR 3 5 CHARTE D APPLICATION DES VACUATIONS 13 2A VACUATION L ARRI RE Terminaison horizontale Terminaison verticale La co...

Page 84: ...izontales combin es en pieds HO facteur de la valeur d une d viation 0 03 du total des degr s de d viation 90 en pieds VT longueur des courses verticales combin es en pieds 15 1A PIEDS POUCES MILLIM T...

Page 85: ...liquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 3 PI 0 9m V2 8 PI 2 4m VT V1 V2 3PI 0 9m 8PI 2 4m 11PI 3 4m H1 2 5 PI 0 8m H2 2 PI 0 6m HR H1 H2 2 5PI 0 8m 2PI 0 6m 4 5 PI 1 4m HO 0...

Page 86: ...ormules sont respect es cette configuration d vacuation est acceptable La section ombrag e l int rieur des lignes repr sente des valeurs acceptables pour HT et VT 90 V1 H1 H2 90 Exemple V1 4 PI 1 2m V...

Page 87: ...r HT et VT HT VT 16 3A Lorsque la configuration de l vacuation exige plus qu un coude de 90 les formules suivantess appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 9 PI 2 7m V2 6...

Page 88: ...sque la configuration de l vacuation exige plus qu un coude de 90 les formules suivantes s appliquent Formule 1 HT 3 5VT Formule 2 HT VT 24 75 pieds 7 5m Exemple V1 4 PI 1 2m V2 1 5 PI 0 5m VT V1 V2 4...

Page 89: ...es formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 5 PI 1 5m V2 6 PI 1 8m V3 10 PI 3 1m VT V1 V2 V3 5PI 1 5m 6PI 1 8m 10PI 3 1m 21PI 6 4m H1 8 PI 2 4m H2 2 5...

Page 90: ...ppliquent Formule 1 HT 3 VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 2 PI 0 6m V2 1 PI 0 3m V3 1 5 PI 0 5m VT V1 V2 V3 2PI 0 6m 1PI 0 3m 1 5PI 0 5m 4 5PI 1 4m H1 6 PI 1 8m H2 2 PI 0 6m HR H1 H2 6PI 1...

Page 91: ...it d appuyer le joint d tanch it contre la chambre de combustion B R installez la d flecteur sup rieur C Avant de fixer les coudes aux collets l arri re de l appareil vous devrez enlever 4 102mm au co...

Page 92: ...ASSE PAS NE SERREZ PAS LA GAINE FLEXIBLE RISQUE D INCENDIE D EXPLOSION OU D ASPHYXIE SI L ENSEMBLE DU SYST ME DE CONDUIT D VENT N EST PAS AD QUATEMENT SOUTENU IL RISQUE DE FL CHIR OU DE SE S PARER UTI...

Page 93: ...s roof pitches are available from your authorized dealer distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated...

Page 94: ...4 101 6mm GAINE FLEXIBLE A tirez la gaine flexible int rieure la longueur requise en tenant compte de la longueur additionnelle n cessaire pour la surface du mur fini Appliquez un g n reux joint de sc...

Page 95: ...t autour Fixez le au toit Ne clouez pas travers la partie inf rieure du solin Imperm abilisez le en le scellant avec du calfeutrage Si possible recouvrez les c t s et le bord sup rieur du solin avec d...

Page 96: ...ellant haute temp rature W573 0007 non fourni sur le rebord ext rieur du collet int rieur de l appareil Installez le premier vent et fixez le en utilisant 3 vis autoperceuses Proc dez de la m me fa on...

Page 97: ...es mat riaux de couvertures G Appliquez un g n reux joint de calfeutrage l preuve de l eau 2 50 8mm au dessus du solin Installez le collet de solin autour du connecteur de terminaison et glissez le ju...

Page 98: ...n du fabricant du syst me d vacuation Des composants d vacuation de diff rents fabricants ne doivent pas tre combin s Une fois que l adaptateur de votre choix est install le reste du syst me d vacuati...

Page 99: ...ne installation dans une maison mobile l appareil doit tre fix au plancher Fixez l aide de vis 10 t te hexagonale ins r es dans les trous de la base teignez toujours la veilleuse et l alimentation en...

Page 100: ...1 NFPA 54 pour les tats Unis D Lorsque vous manipulez des conduites de gaz soutenez la soupape de gaz pour viter que les con duites ne se plient E Le raccord flexible de l alimentation en gaz devrait...

Page 101: ...E FINITION POUR MAINTENIR LES D GAGEMENTS SI L OSSATURE OU LES MAT RIAUX DE FINITION SE TROUVENT UNE DISTANCE INF RIEURE CELLE INDIQU E ILS DOIVENT TRE FAITS ENTI REMENT DE MAT RIAUX NON COMBUSTIBLES...

Page 102: ...1397 10 01 14 FR 301 2 775mm 343 4 883mm 115 16 49mm 71 2 192mm 141 2 368mm DESSUS DEL ENCEINTE MAT RIAU DEFINITION RACCORDEMENT LECTRIQUE EMPLACEMENT DEL ENTR E DUGAZ 5 7 1 DIMENSIONS MINIMALES DE L...

Page 103: ...et sur les c t s de l vent et de 3 76mm au dessus doit tre maintenu sur toutes les courses horizontales Utilisez l espaceur coupe feu W010 1777 fourni SECTIONS D VENTS VERTICALES Un d gagement minimal...

Page 104: ...PLUSLAPENTE 161 4 412mm 0 0MM SILESMAT RIAUX SONTINCOMBUSTIBLES COMMEDELABRIQUE ETDELAPIERRE COMBUSTIBLE INCOMBUSTIBLE BRIQUE ENCEINTE AVEC VACUATION SUR LE DESSUS L enceinte de l appareil doit avoir...

Page 105: ...IAUX SONTINCOMBUSTIBLES COMMEDELABRIQUE ETDELAPIERRE INCOMBUSTIBLE Voir la section VACUATION ENCEINTE AVEC VACUATION L ARRI RE L enceinte de l appareil doit avoir une hauteur minimale de 36 914mm Afin...

Page 106: ...mat riaux combustibles sont respect s Vous pouvez utiliser un mat riau incombustible pourvu que les d gagements minimaux aux mat riaux combustibles soient appliqu s Le volume minimal de l enceinte do...

Page 107: ...ts des c t s et du dessus de 2 50 8mm pour chaque pouce 24 5mm suppl mentaire de projection Si vous utilisez un moulure optionelle les m me r gles s applique commen ant du sommet du moulure Garantir q...

Page 108: ...NTS LA CHALEUR AFIN DE PR VENIR LA D COLORATION 73 1 108 W415 1397 10 01 14 FR Le d gagement d une tablette combustible l appareil peut varier selon la profondeur de la tablette Utilisez le graphique...

Page 109: ...EN RESPECTEZ TOUS LES D GAGEMENTS AUX MAT RIAUX COMBUSTIBLES AVANT D ENLEVER LA PORTE TEIGNEZ L APPAREIL ET ATTENDEZ QUE CE DERNIER SOIT FROID AU TOUCHER LES PORTES SONT LOURDES ET FRAGILES MANIPULEZ...

Page 110: ...lation Prenez le temps de bien installer les braises incandescentes pour obtenir le meilleur effet possible La couleur des b ches peut varier Lors de la premi re utilisation de l appareil les couleurs...

Page 111: ...acez le sur la porte vitr e tel qu indiqu LOGO 12 7mm 12 7mm E Placez la b che crois droite W135 0547 en place par alignez les trous en bas de la b che avec les deux tiges situ e dans la b che droite...

Page 112: ...es comme indiqu sur le couvercle Pour ouvrir le bo tier de batterie glisser le piece de l arri re hors du bo tier de batterie D Enlever l cran de protection en le levant vers le haut hors des quatre v...

Page 113: ...nt la soufflerie contre le caisson ext rieur pour que l adh sif colle bien l appareil NOTE VEILLEZ CE QUE TOUS LES FILS RESTENT LOIGN S DE LA SOUFFLERIE H Remettez le module de commande dans sa positi...

Page 114: ...TERRE INTERRUPTER ACS IPI D branchez ces connecteurs de l interrupteur marche arr t pour les connecter au thermostat optionnel TRANSFORMATEUR T L COMMANDE ON OFF Cette appareil est fourni avec une sa...

Page 115: ...r Ouvrez les fen tres N allumez aucun appareil Ne touchez aucun interrupteur lectrique n utilisez aucun t l phone dans votre immeuble De la maison d un voisin appelez im m diatement votre fournisseur...

Page 116: ...until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is depresse...

Page 117: ...ression comme d crit sur le diagramme ci dessous Assurez vous que le br leur principal fonctionne HI La v rification de la pression de sortie s effectue comme ci dessus en utilisant la vis B Le manom...

Page 118: ...d quatement D Assurez vous que la flamme de la veilleuse est assez puissante pour envelopper la sonde de flamme et ou le thermocouple thermopile et qu elle atteigne le br leur E Remettez en place les...

Page 119: ...uvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de flamme et l allumeur NOTE Vous devrez possiblement nettoyer le capteur de flamme l aide d...

Page 120: ...z le cadre de la porte avec la devanture vers le bas en prenant soin de ne pas gratigner la peinture B Centrez la vitre avec joint d tanch it dans le cadre avec le c t pais du joint d tanch it orient...

Page 121: ...l appareil Date d installation de l appareil Num ro de la pi ce Description de la pi ce Fini IDENTIFIE LES ARTICLES QUI NE SONT PAS ILLUSTR S POUR PLUS D INFORMATION CONTACTEZ VOTRE D TAILLANT AUTORI...

Page 122: ...X4 REQ D W385 0334 W562 0009 JOINT D TANCH IT NON 24 23 22 21 20 19 18 14 15 16 17 13 W010 3070 LOQUET DE PORTE X4 W010 0538 7 CAPUCHON CONDUIT avec JOINT D TANCH IT W290 0039 7 JOINT D TANCH IT CAPC...

Page 123: ...5 THERMOCOUPLE W680 0004 THERMOPILE W010 0800 VEILLEUSE PL W010 0798 ENSEMBLE DE VEILLEUSE GN W010 0799 ENSEMBLE DE VEILLEUSE PL 14 W720 0062 TUBE DE VEILLEUSE RACCORD W240 0006 ALLUMEUR AVEC FILS 35...

Page 124: ...ERY BACK UP OUI 14 14 56 14 57 14 58 14 59 14 59 14 64 14 65 14 66 W707 0010 TRANSFORMATEUR OUI 57 58 59 60 61 62 W750 0309 HARNAIS DE FILS NON 55 47 48 49 50 51 52 53 W290 0029 14 54 14 60 14 63 14 5...

Page 125: ...E DE CONVERSION MILLIVOLT GN PL W175 0376 TROUSSE DE CONVERSION MILLIVOLT PL GN W175 0377 TROUSSE DE CONVERSION L CTRONIQUE GN PL W175 0378 TROUSSE DE CONVERSION L CTRONIQUE PL GN 1 W175 0378 1 W175 0...

Page 126: ...situent entre 3 2 et 2 8 volts C A Syst me de d pannage piles s il y a panne de courant V rifiez les piles Une connexion desserr e ou causant un court circuit Retirez et r installez le harnais de fil...

Page 127: ...rant de la flamme V rifiez si le bon injecteur de veilleuse est install et que l alimentation en gaz est conforme aux sp cifications du manuel Souvenez vous que la flamme transporte le courant redress...

Page 128: ...eur principal est bleue paresseuse et transparente Syst me d vacuation bloqu Enlevez ce qui obstrue Dans des conditions de froid extr me une accumulation de glace peut se former sur la terminaison et...

Page 129: ...principal le bouton du gaz est HI l interrupteur mural thermostat est ON Le thermostat ou l interrupteur sont d fectueux Reliez un fil de d rivation entre les bornes de l interrupteur mural si le br...

Page 130: ...sur la diagramme ci dessous Assurez vous que le br leur prinicpal fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LA VIS VERS LA DROITE POUR SCELLER NE SERREZ...

Page 131: ...la buse d vacuation amovible V rifiez tous les joints scell s et la plaque d expansion V rifiez si la chemin e ne serait pas bloqu e V rifiez si la chemin e est install e selon les codes du b timent L...

Page 132: ...u produits d entretien nuisibles ne seront pas la responsabilit de NAPOL ON Toutes les pi ces remplac es en vertu de la politique de Garantie vie limit e du Pr sident ne peuvent faire l objet que d un...

Page 133: ...bl mes particuliers Travail effectu Nom du technicien D taillant Historique d entretien Wolf Steel Cet appareil doit tre entretenu annuellement selon son usage 19 0 HISTORIQUE D ENTRETIEN 133 W415 139...

Page 134: ...44 1 20 0 NOTES 134 W415 1397 10 01 14 FR...

Page 135: ...44 1 135 W415 1397 10 01 14 FR...

Page 136: ...s lectriques Foyers ext rieurs Grils gaz de qualit Foyers Chauffage et Climatisation Grils composez 514 737 6294 napoleonproducts com 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Roa...

Reviews: