StarLink™ Connect SLECDMA-CB Series Alarm Communicators -- Installation Instructions 

 

SLECDMA-CB-TF-C

 - Commercial / Residential Burglary 

and Residential Fire Network Compatible CDMA alarm 
capture radio communicator in white metal housing.  In-
cludes 

SLE-ULPS-R 

power supply and 

TRF12/T123 

plug-in 16.5V / 20VA transformer.   

 

ADDITIONAL COMPONENTS 

  In addition to the models listed above, the 

following sub-assemblies are available: 

 

SLE-WIFI-MODULE

 - Allows your StarLink

 

device to connect to the Internet by means of a wireless 
(Wi-Fi) link, eliminating a wired Ethernet cable connec-
tion.   

SLE-DLCBL

 - Download Cable, 6 feet. 

SLE-ANTEXT30

 - Extended antenna with 30 feet of cable. 

SLE-ANTEXT50

 - Extended antenna with 50 feet of cable. 

SLE-ANTEXT75

 - Extended antenna with 75 feet of cable. 

  (Any suitable external cellular antenna is permitted by 

UL).  Always follow the manufacturer's installation in-
structions.  

Note:

  Antennas are not Listed by UL.  For 

3/4G radios where an External Antenna needs to be 
installed outside of the room in which the radio is in-
stalled (maximum 30 meters (98 feet) in Residential ap-
plications), please use RF Transmitter Board 
9GPS5320EXAPSLD available from our Customer Ser-
vice Department, if not provided.  The 

 

9GPS5320EXAPSLD is identified by "two red dots" lo-
cated on the lower right corner of the board.  See 
WI2222 included with the 9GPS5320EXAPSLD for the 
simple installation procedure.   

 

SPECIFICATIONS

 

 The 

following 

specifications 

apply to all StarLink radio mod-

els in these installation instructions unless otherwise stated: 

 

  Electrical Ratings for +12V (both models powered by the 

control panel) 



Input Voltage:  10-15VDC (power-limited output from con-
trol panel).  Do NOT connect to full-wave rectified (FWR) 
power.   



Input Current:  

 

SLECDMA-CB-C

 standby current:  100mA (110mA 

with telco EOLR) 

 

SLECDMA-CB-TF-C

 standby current:  100mA 

(110mA with telco EOLR) 

 

Transmission current (all models):  200mA max. 

 

  Electrical Ratings for the IN 1 Burg/Fire Input: 



Input Voltage:  9-15VDC.   



Maximum Input Current:  Up to 2mA from control panel 
supply circuit 

 

WI2247ALF  8/18 

333 Bayview Avenue Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2018 

OVERVIEW 

 The StarLink

 Connect models 

SLECDMA-CB-C

 and 

SLECDMA-CB-TF-C

 are multi-function Commercial / Resi-

dential Burglary and Residential Fire alarm radio communi-
cators and supervised system interface modules.  They pro-
vide several options to the user:   

 

1. A monitoring path to a central station through a digital 

CDMA radio and optionally through a TCP/IP network to 
the Internet using a hardwired or optional Wi-Fi connec-
tion; 

 

2. Notification alerts of alarm system changes to a mobile 

device.  Notifications use 

iBridge Messenger 

SMS text 

messaging and/or emails to inform the user and/or deal-
er of system state changes.  For this release, these noti-
fications are enabled in the 

iBridge Connected Home 

Services 

website at 

http://ibridge.napconoc2.com

 

3. Both radio models are compatible with most 12VDC 

alarm control panels, including Honeywell and DSC 
(always adhere to the documentation provided by the 
control panel manufacturer).  Residing in the Windows 

System Tray

, the 

StarLink Connect 

application allows 

you to use your customary control panel communication 
software for remote programming and communication: 

 



DSC 

DLS 

 



Honeywell 

Compass

®

 

 

 

  NAPCO control panels are programmed in the tradition-

al way using PCD-Windows Quickloader software.   

StarLink Connect

 is available on the enclosed CD.   

 

  If required, mount the unit to a single-, dual-, or three-gang 

electrical box and route the wires through the back knock-
out(s), or as specified by local codes.  

See WI2140 for pro-

gramming instructions 

(all manuals are available for 

download at 

http://tech.napcosecurity.com/

). 

 

  StarLink SLE Series radios use proprietary data-capture 

technology that captures the alarm report from the control 
panel and transmits the alarm signals to the SLE Control 
Center (the Napco "NOC"); the alarm signals are then for-
warded to ANY central station via Contact ID or Sur-Gard 
System II or Sur-Gard System V central station receivers via 
TCP/IP using standard line security.  The SLE Control Cen-
ter reports a trouble signal in the event that the network does 
not receive the expected supervision signal from the wire-
less communicator.  In addition, both StarLink radio models 
can be powered directly from the control panel.   

  The StarLink radio model names are as follows: 

 

SLECDMA-CB-C 

- Commercial / Residential Burglary and 

Residential Fire Network Compatible CDMA alarm cap-
ture radio communicator in white metal housing.  Pow-
ered directly from control panel (no power supply, no 
transformer).   

 

StarLink

 Connect Series  

SLECDMA-CB-C & SLECDMA-CB-TF-C 

Multi-Function Alarm Communicators  

INSTALLATION INSTRUCTIONS 

Summary of Contents for StarLink Connect Series

Page 1: ...models SLECDMA CB C and SLECDMA CB TF C are multi function Commercial Resi dential Burglary and Residential Fire alarm radio communi cators and supervised system interface modules They pro vide sever...

Page 2: ...r and correct reporting formats and codes TB7 IN 2 See TB9 below TB8 GND Common ground terminal TB9 IN 3 Both terminals IN 2 and IN 3 default to User Defined no end of line resistor supervision requir...

Page 3: ...er When DS15 is flashing rapidly Push button on Wi Fi module is being pressed When DS15 is flashing steady with 1 quick blink off eve ry 2 seconds Reporting signal to NOC When DS15 is flashing steady...

Page 4: ...used in accordance with the In struction Manual may cause harmful interference to radio communications However there is no guarantee that in terference will not occur in a particular installation If...

Page 5: ...at the interval determined by your rate plan rect the interference by one of more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipmen...

Page 6: ...rm E122 Medical Alarm E100 24 hour Aux Alarm E150 24 hour Aux Restore R150 Burg Perimeter Alarm E131 Burg Interior Alarm E132 Keypad Holdup Alarm ambush E121 Keypad Panic Alarm E123 Keypad Emergency A...

Page 7: ...1 not supervised IN2 and IN3 can be supervised Keep all non power limited wiring separate from all power limited wiring inside the housing by 1 4 Remove shunt J2 to isolate relay common from ground i...

Page 8: ...33 30 31 32 Control Panel PC Board Refer to section SUPPLYING POWER TIP RING TIP RING TEL LINE PHONE 2 2K CONTROL PANEL HOUSING STARLINK RADIO HOUSING StarLink Radio Terminals 9 10 11 REMOTE BUS BLK...

Page 9: ...ows 6 3 6 CD located in the StarLink Connect root folder Save the StarlinkConnectSetup exe file to a folder on your PC 2 Run StarlinkConnectSetup exe and follow the installation prompts After the inst...

Page 10: ...e is ready to connect with the DSC DLS Programming Software 3 Launch the DSC DLS Programming Software and log in DSC Control Panel Connections normally When connected to the DSC DLS Programming Softwa...

Page 11: ...e Option 1 Option 1 turns on off communications Option 5 turns on off 3rd tele phone number 381 Disable Option 3 Option 3 turns on off code reporting 382 Enable Option 5 Option 5 enables disables comm...

Page 12: ...k Connect icon in the System Tray turns green with a black C in the center shown at right the Napco StarLink Connect software is ready to connect with the Compass Downloader for Windows software 3 Lau...

Page 13: ...nect To allow notification alerts iBridge Messenger text messaging mobile device app communication for remote system control and the Napco StarLink Connect software to support Honeywell Compass softwa...

Page 14: ...to display the first choice of the menu driven programming functions Press 0 for NO or press 1 for YES in response to the displayed menu selection Press keypad star key to display the next selec tion...

Page 15: ...TANT WIRING METHODS Incorrect Correct Use pigtail and wire nut crimp connector PIGTAIL WIRE NUT OR CRIMP CONNECTOR PIGTAIL For single conductor terminal blocks like the type shown at left to terminate...

Page 16: ...er assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be li...

Reviews: