 SLE-LTE Commercial Series Alarm Communicators -- Installation Instructions 

 

armed condition, any loss of communication must be 
treated as a Burglary Alarm at the Central Station.

  

 

The following models are available: 

 

SLE-LTEV-CFB-PS

:  Commercial / Residential Fire and 

Burglary Radio in red metal housing with SLE-ULPS-R 
power supply and 16.5V / 20VA transformer mounted 
inside housing 

SLE-LTEV-CB-TF

:  Commercial / Residential Burglary 

and Residential Fire Radio in white metal housing with 
SLE-ULPS-R power supply and TRF12/T123 plug-in 
16.5V / 20VA transformer 

SLE-LTEV-CFB

:  Commercial / Residential Fire and Bur-

glary in red metal housing.  Powered directly from control 
panel (no power supply, no transformer, rated 12/24VDC 
input) 

SLE-LTEV-CB

:  Commercial / Residential Burglary and 

Residential Fire Radio in white metal housing.  Powered 
directly from control panel (no power supply, no trans-
former) 

 

 

The following features are included with models that include 
a SLE-ULPS-R power supply:   

 



Power limited output to the StarLink radio PC board 12V 
input terminals 



Battery connection red and black flying leads 



Monitored battery charging and Active battery test circuits 



StarLink radio trouble input (from StarLink radio PC board 

PGM1 

terminal to detect StarLink radio trouble) 



Requires a sealed lead acid min 4AH / max 7AH battery 
for minimum 24-hour standby time (max charge current 
200mA). 



Trouble relay output (

C

N/O 

and 

N/C

 terminals) to wire 

to a panel zone dedicated to "LTE Trouble" (dry con-
tacts).  Remove jumper "

J2

" to isolate common from 

ground 



Green 

AC ON 

LED visible from the exterior housing 



Yellow 

TROUBLE 

LED on PC board.  Flashes signify: 

 

One flash: AC fail / brownout (2 hour delay) 
Two flashes: Low battery 
Three flashes: Charging circuit trouble 
Four flashes: StarLink radio trouble 

 

 

The housing-mounted transformer (when provided) is mount-

StarLink™ SLE-LTE Commercial Series  

Alarm Communicators  

INSTALLATION INSTRUCTIONS 

WI2226ALF  8/18 

333 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2018 

INTRODUCTION 

 The 

StarLink

 Commercial / Residential Fire and Burglary 

alarm capture radio communicators are fully supervised, 
wireless digital two-way subscriber units supported by an 
extensive nationwide wireless network.  All models are 
compatible with most 12VDC alarm control panels (always 
adhere to the documentation provided by the control panel 
manufacturer).  Model 

SLE-LTEV-CFB 

is compatible with 

most 12 or 24VDC control panels.  All can function as a 
backup to existing telephone lines, or as sole path primary 
communicators.  In backup mode, all units will automatical-
ly switch the communication channel from the telephone 
line to the network when telephone line trouble is detected.  

See WI2140 for programming information.   

  The SLE-LTE Series radios use data-capture technology 

that captures the alarm report from the control panel and 
transmits the alarm signals to the SLE Control Center; the 
alarm signals are then forwarded to ANY central station via 
Contact ID or Sur-Gard System II or Sur-Gard System V 
central station receivers via TCP/IP using standard line 
security.  The SLE Control Center reports a trouble signal 
in the event that the network does not receive the expected 
supervision signal from the wireless communicator.  

 

For Commercial Burglary installations, under the 

(

 

(

 

(

 

(

 

(

 

(

 

(

 

(

 

(

 (     ) 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

(1) 

(2) 

Control 
Panel 

Network  

Operator 

UL Classified StarLink Network  

Operations Center 

(3) 

CENTRAL 

STATION 

(5) 

(4) 

STARLINK RADIO REPORTING PATH 

 

The diagram below shows the transmission path of a 
signal from the StarLink radio to the central station.   

 

1. 

Signal from a Control Panel.  

 

2. 

StarLink

 radio receives the signal transmission 

(from the TIP an RING wires); sends RF signal 
through the network operator.  

3. 

Network Operator

, part of the vendor system, a 

section of the cellular spectrum.   

4. 

SLE Control Center

, receives and routes data. 

5. 

Central Station

StarLink 

Radio 

AGENCY LISTINGS 



UL 864 Standard For Control Units and Accessories For 
Fire Alarm Systems, 10th Edition 



UL 1610 Standard For Central-Station Burglar-Alarm Units 



UL 985 Standard For Household Fire Warning System Units 



UL 1023 Standard For Household Burglar-Alarm System 
Units 

LTEV models are 

Verizon

®

 Network Certified

 

Summary of Contents for SLE-LTEV-CB

Page 1: ...com Note Technical Service is for security professionals only Publicly traded on NASDAQ Symbol NSSC NAPCO 2018 INTRODUCTION The StarLink Commercial Residential Fire and Burglary alarm capture radio c...

Page 2: ...structions Note Antennas are not Listed by UL For LTE radios where an External Antenna needs to be in stalled outside of the room in which the radio is installed maximum 30 meters 98 feet in Resident...

Page 3: ...c com Located at the bottom of the StarLink radio PC board the 17 terminals are described as follows TB1 PWR 12V Note Model SLE LTEV CFB is rat ed 12 24VDC input Refer to section STEP 4 APPLY POWER TB...

Page 4: ...rent due to the application such as when 24 hour standby time is required for Fire or CO the SLE ULPS R Charger Module accessory must be used to charge an additional battery and to supply the power fo...

Page 5: ...StarLink radio can also func tion as a backup to the existing telephone lines install jumper 3 in terminal block X5 When used as a backup communicator and when it senses telephone line trouble the Sta...

Page 6: ...receivers via TCP IP STARLINK RADIO RELATED EVENT REPORT CODES Contact ID by default EVENT AREA CONTACT ID CODE ZONE IN 1 Fire 0 E110 990 1A IN 2 Panic 0 E120 992 22 IN 3 Trouble 0 E300 993 F3 Low Ba...

Page 7: ...PGM activates the control panel zone and the panel generates a trouble that is sent to the central station All installations also require wiring an output from the control panel as follows With Gemin...

Page 8: ...he transformer compartment knockouts Keep all non power limited wiring separate from all power limited wiring inside the housing by 1 4 In addition maintain a minimum 1 4 separation of all primary wir...

Page 9: ...ng inside the housing by 1 4 Remove shunt J2 to isolate relay common from ground i e jumper on wet circuit common off dry contact When wet configuration is used the power should be derived from the al...

Page 10: ...ther the TRF12 T123 16 5V 20VA transformer or the chas sis mounted 16 5VAC 20VA transformer Transformer optional Optional When Power Supply SLE ULPS R is not used connect Panel Aux Power to StarLink t...

Page 11: ...IP STARLINK RADIO HOUSING Power Supply SLE ULPS R Either the TRF12 T123 16 5V 20VA transformer or the chassis mounted 16 5VAC 20VA transformer optional Transformer TELCO QUAD WIRE Optional When Power...

Page 12: ...nstructions for the GEMC F8ZCPIM as a Monitor Zone Only When PGM1 is wired to a GEMC F8ZCPIM zone replace the 2 2k ohm EOL resistor with a 560ohm 1 2 watt min EOL resistor Connect PGM1 to the negative...

Page 13: ...Radio Terminals PANEL RING PANEL TIP STARLINK RADIO HOUSING Either the TRF12 T123 16 5V 20VA transformer or the chassis mounted 16 5VAC 20VA transformer StarLink BATTERY RED BLACK Power Supply SLE ULP...

Page 14: ...TERY RED BLACK Refer to section SUPPLYING POWER 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TIP 17 16 RTS R PANEL TX B PANEL RX G CTS Y StarLink Radio Terminals PANEL RIN...

Page 15: ...ring Diagram for PRIMARY Reporting Configuration GEM X255 GEM P9600 GEM P3200 Control Panels Use when telephone line is NOT available AUX POWER CONTROL PANEL HOUSING 13 14 15 16 17 18 19 20 21 22 26 2...

Page 16: ...GRAY GRAY Optional When Power Supply SLE ULPS R is not used connect Panel Aux Power to StarLink terminals 1 and 2 observing polarity GRN RED YELLOW BLACK StarLink BATTERY RED BLACK Refer to section S...

Page 17: ...report Open Close radio remembers last state of panel for Napco panels when used with local download cable 5 BURG without DACT Use IN2 or IN3 for both Alarm and Trouble Panel has alarm and Trouble Rel...

Page 18: ...wire to a zone on the control panel GEM Tamperkit consists of Description QTY SC206LF Slotted Pan Head 6 32 x 3 4 Machine Screw 6 SW105 Tamper Switch 2 Tamper Switch Mounting Instructions Back Tamper...

Page 19: ...3 TRANSFORMER FOR CONNECTION TO SLE CHARGER BOARD UL LISTED SURFACE OR FLUSH MOUNT OUTLET BOX AND NON SWITCHED RECEPTACLE WALL TRANSFORMER SECONDARY WIRING CONDUIT LIMITED TO 20 FEET MAXIMUM LENGTH Ma...

Page 20: ...ompromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all cases provid...

Reviews: