DESCRIPTION 

This variable-purpose power supply is suitable for many differ-
ent applications for security, access control and CCTV system 
accessories that need supplementary power.  NP-LPS6-24VDC 
power supply/charger converts low voltage AC input into 6VDC 
or 12VDC (@ 1.5 amps or 24VDC @ 1A of continuous supply 
current).  See specifications that follow.   

 

FEATURES 

Dip switch selectable 6VDC-12VDC-24VDC. 

1.5 amp continuous supply current at 6VDC-12VDC. 

1A continuous supply current at 24VDC. 

Filtered and electronically regulated output. 

Built-in charger for sealed lead acid or gel type batteries. 

Maximum charge current 300mA. 

Automatic switchover to stand-by battery when AC Fails. 

Circuit breaker battery protection (fused available). 

AC input and DC output LED indicators. 

Extremely compact design. 

Includes battery leads. 

    Board dimensions: 70mm L x 60mm W x 40mm H 

 

Voltage Output/Transformer Selection Table: 

INSTALLATION INSTRUCTIONS 

1.    Mount NP-LPS6-24VDC in desired location / enclosure. 
2.

    Unit is factory set for 12VDC.  

For 6VDC output dip switch 

2 off, for 24VDC output dip switch 1 on. 

3.    Connect proper transformer to terminals marked [AC] (refer 

to Voltage Output/Transformer Selection Table). 

       Use 18 AWG or larger for all power connections (Battery, 

DC output). 

        Keep  power  limited  wiring  separate  from  non-power 

limited wiring (115VAC / 60Hz Input, Battery 

        Wires).  Minimum .25” spacing must be provided. 

4.    Devices to be powered should be connected to terminals 

marked [+ DC] and [– DC] carefully observing polarity. 

        Note: 

It is important to measure output voltage before con-

necting devices.  This helps avoid potential damage. 

5.    Connect battery to terminals marked [BAT +] and [BAT –] 

(battery leads included).  Use two (2) 12VDC batteries con-
nected in series for 24VDC operation. 

        Note:   

When batteries are not used, a loss of AC will result 

in a loss of output voltage. 

 

LED Diagnostics: 

Terminal Identification: 

R

333 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 

NP-LPS6-24VDC 

LINEAR POWER SUPPLY 

WI1325D  12/05 

© NAPCO 2005 

Red  

(DC) 

Green 

(AC) 

Power Supply Status 

ON 

ON 

Normal operating condition. 

OFF 

ON 

No DC output.  Short circuit or thermal overload condition. 

OFF 

OFF 

No DC output.  Loss of AC.  Discharged or no battery present. 

Terminal 

Legend 

Function/Description 

AC 

Low voltage AC input (refer to voltage output/transformer 
selection table). 

+ DC - 

 

6VDC-12VDC @ 1.5 amp continuous supply current. 
24VDC @ 1A continuous supply current. 

+ BAT - 

Stand-by battery connections.  Maximum charge rate 
300mA. 

Item 

Description 

Dimension  Volume 

Memo 

Instruction Sheet 

A4 

 

Wire 

18AWG 22cm 

Red 

Wire 

18AWG 22cm 

Black 

Double Stick Foam Tape  60*20*7mm 

 

APPENDIX LIST

 

Output 

Voltage Selector 

(DIP SWITCH) 

Transformer 

24VDC @ 1A continuous 

supply current 

1.  ON 
2.  ON 

P-TRF2450 

12VDC @ 1.5 amp con-

tinuous supply current 

1.  ON 

2.  OFF 

P-TRF1650 

6VDC @ 1.5 amp con-

tinuous supply current 

1.  OFF 
2.  OFF 

P-TRF1650 

 

AC

 

 