EZM GROUP OPTIONS:
Up to 2 Groups of 4 Zones each may be pro-
grammed depending on the number of Zones used and which EZM mod-
ules are connected. Each Group represents 4 Zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations
above.
3. Press
U
to save.
EZM GROUP OPTIONS (ADDRESS 1455 & 1456)
EZM Group 1
ADDRESS 1455
EZM Group 2
ADDRESS 1456
EZM TYPE
DATA
ENTRIES
OPTION
blank (•)
Not used
(No EZM
present)
1
4-Zone EZM
EZM GROUP
1
9-12
2
13-16
ZONES
COVERED
NORMAL