NAPCO Gemini GEM-P1664EX Datasheet Download Page 2

The GEM-P1664 Hybrid 8 to 64-Zone Control/
Communicator features 8 zones expandable 
to 64 zones with multiplexing and supports 
proven, reliable, NAPCO crystal-control 
transmitters and uses advanced helically-filtered 
receivers, too. Supporting up to 64 user codes 
and 8 16 relays, the GEM-P1664 comes in two 
configurations suitable for 

EN50131-1

 and/or 

CE installations

. This Gem control features easy 

“Self-Programming Plus” keypad programming 
(for all zones), which includes new alpha 
keypad question-prompts, even for setting test 
timer, fire zones and exit/entry and follower 
zones. Additionally, the panel can be remote 
up/downloaded using easy-to-use NAPCO 
Quickloader Software (V5.0 or greater) with true 
Windows-style functionality, including cut/paste, 
drop/drag, etc. 

FEATURES

 8 Hardwire/Wireless Zones on board

 Up to 64 zones with multiplex expansion 

including 2 two 2-wire fire zones 

 With multiplexing, can accommodate up to 

64 EOL zones (from custom alpha keypads or 
multiplex modules)

 EZ Programming2 More comprehensive, 

menu-driven programming for all zones plus 
test timer.

 Up to 64 user codes

 Up to 4 areas

 3 on-board outputs, up to16 external relay 

outputs (RM3008s).

 Up to 2 NAPCO helically-filtered, crystal-

control RF receivers

 Interior bypass group with programmable 

automatic interior bypass

 600 event log

 Auto Arm

 Uses up to 7 of any of the Classic/RP- or K-

Series Stay & Away keypads

 Programmable telephone line cut supervision 

with delay

 3 Keypad panics (F, P, A)

 Supports all major communicator formats, 

including: 4/2, SIA, 4+2 and Point ID, plus 
pager

 Backup/double/split reporting; three 20-digit 

telephone numbers

 Dynamic battery test

 Reports alarms, restores and troubles by zone.

 2 programmable entry delay times

 Chime by zone

 8 EOL burglary zones programmable for area, 

E/E delay, interior, follower, day zone, chime, 
fire options, sensor watch, swinger shutdown, 
cross zoning , etc.

 Supports series zone doubling and Loop 

supervision using double EOL resistors 
(feature requires use of GEM-EZM4/8 
Multiplex Modules)

 Multiplex Expandability with GEM EZM4/8 or 

GEM EZM8 zone expansion modules

 Quickloader up/downloading, including 

unique unattended method

 Choice of RF receivers

 Partitioning by area

 Event log with open/close suppression

 Event log viewable at keypad (total log, 

burglar alarm log, fire alarm log, system 
trouble log, o/c log)

 Cellphone-style keypad programming of zone 

descriptions ( text)

 Programmable 50Hz Clock Setting

 Programmable Daylight Savings Time

 Programmable Security Bypass (code required 

for bypass)

 Un-Bypassing while disarmed (code required)

 Temperature Display at Keypad (-30 to 60

0

Celsius or -22 to 140

0

F Fahrenheit) with 

optional GEM-TEMP64 Indoor/Outdoor 
Temperature Sensor (Note: Keypad 
Temperature Display replaces Date on Display)

 Programmable High/Low Temperature Alarm 

Reporting (requires feature enabled; zone 6) 

 24 Hour day zone trouble

 Programmable security blocking of keypad 

display messages –Informational displays 
made visible contingent on user’s assigned 
area(s) within system

 Programmable Swinger Shutdown (2 or 3 

activations – selectable)

 Zone Anding/Cross Zoning (Grouping of zones 

in which sequential zone activation is required 
to generate an alarm)

SPECIFICATIONS

 Environmental Classification: Class I (+5C to +40C), 

Class II (-10C to +40C) and Class III (-25C to +50C)

 Input power: 16.5VAC via Class 2 plug-in 20VA, 40VA 

or 50VA transformer

 Loop voltage: 10-13VDCdc

 Loop current: 32.5mA with 2.2k ohm EOLR; 5mA for 

2-wire fire

 Loop resistance: 300 ohm max.; 50 ohm max for 

2-wire fire

 Aux & remote power: 12VDC regulated (11.7 to 

12.5VDC)

 Maximum Combined standby current: 650mA

 Maximum Alarm current: 2A

 Burg. voltage output: 1 

 Programmable negative outputs: 2

 Loop response 750ms, programmable 50ms to 

2,000ms

POWER

 (With Type A Power Supply):

Grades 1 and 2 Installations with 4AH battery: 

Maximum combined standby current: 210mA

Maximum combined standby current and alarm current: 

650mA

Grades 1 and 2 installations with 7AHbattery:

Maximum combined standby current is: 460mA

Maximum combined standby current and alarm current: 

500mA

Grade 3 installations (requires 7AH battery):

Maximum combined standby current is : 110mA

Maximum combined standby current and alarm current: 

500mA

ORDERING INFORMATION

GEM-P1664EX Control Panel

 suitable for use 

in EN50131-1 Installations (transformer not 

supplied).

GEM-P1664EX-230

 Control panel, as above, 

prewired with transformer (included) suitable for 

use in EN50131-1 CE installations., CE marked. 

PCD2000 NAPCO QUICKLOADER

®

  

Up/

Downloading Software For panel programming, 

requires version 5.0 or greater. (Windows-

based).

GEM-RP1CAe2

 Deluxe Custom Alphanumeric 

Dual-Line Display Keypad with built in 4-Zone 

Expansion Module. Classic NAPCO user 

functionality. (New Black and White Decorator 

Styling). (Firmware Version 9A+)

GEM-K1CA,

 as above, with STAY and AWAY 

user functionality. (Firmware Version 9A+)

GEM-TEMP64

 Optional temperature sensor, 

for use with either of the two keypads above, 

programmable for celsius or fahrenheit. Indoor 

or outdoor temperature display at keypad.

GEM-RP2ASe2

 Alpha/Icon Keypad (Version 7 

f support required).

GEM-K2AS

, as above, with STAY and AWAY 

user functionality. (Version 7 f support 

required).

GEM-RP3DGTL

 Digital Keypad (Version 3 

f support required).

GEM-K3DGTL

, as above, with STAY and AWAY 

user functionality. (Version 3 f support 

required).

GEM-EZM4/8

 Mulitplex Module for 4 to 8 zones 

expansion (supports series zone doubling and 

loop supervision using double EOL resistors).

GEM-EZM8

 8-Zone Mulitplex Module

Choice of NAPCO Wireless Receivers & Full 

Range of NAPCO GEM or Libra Wireless 

Transmitters (consult manual for selection for 

your region’s frequency):
GEM-K4RF

 Fixed English Language Display 

Keypad with 32Pt. Built-in Wireless Receiver 

(Version 2 f).

GEM-K4RF-SPAN

 Spanish Language version of 

above.

 

Note: Other language versions, also available: 

Call NAPCO International Sales for info.

LIBRA RECV255-433

 255 point receiver

LIBRA RECV8-433

 8 point receiver

LIBRA-REC16433

 Wireless 16 Point Receiver

LIBRAREC96433

 Wireless 96 Point Receiver

LIBRA-TRANS433

 Wireless Door Contact

LIBRA-PIR433

 Wireless PIR

LIBRA-KEYF433

 Wireless KeyFob

LIBRA-SMK433 

Wireless Smoke Detector

LIBRA-GB433 

Wireless Glass Break Sensor

GEM-RECV255

 Wireless Receiver, 96 Zones

GEM-RECV96

 Wireless Receiver, 96 Zones

GEM-RECV16

 Wireless Receiver, 16 Zones

GEM-RECV8

 Wireless Receiver, 8 Zones

GEM-TRANS2

 Window/Door Transmitter, 2-Pt

GEM-RTRANS

 Recessed Window/Door 

Transmitter

GEM-KEYF

 Key Fob Transmitter

GEM-SMK

 Wireless Smoke Detector

GEM-PIR

 Wireless PIR

GEM-PIRPET

 Wireless Pet Immune Transmitter

GEM-DT

 Wireless Dual-Technology Sensor

GEM-GB

 Wireless Glass-Break Detector

WI1388

 Instruction/Programming Manual

WI1386

 Instruction/Programming Manual with 

RP1/K1 Keypads

WI1418

 GEM-EZM4/8 Zone Expansion with 

GEM-P1664 Control

333 Bayview Ave., Amityville, NY, USA 11701

+1.631.842.9400 

 +1 (631) 842-2382 fax 

www.napcosecurity.com

NASDAQ: NSSC

email: [email protected]

A497 © NAPCO, 6/05

Preliminary specifications subject to change. 

GEM-

P1664

 zone hybrid control