![NAPCO Gemini GEM-P1664EX Datasheet Download Page 2](http://html2.mh-extra.com/html/napco/gemini-gem-p1664ex/gemini-gem-p1664ex_datasheet_3272302002.webp)
The GEM-P1664 Hybrid 8 to 64-Zone Control/
Communicator features 8 zones expandable
to 64 zones with multiplexing and supports
proven, reliable, NAPCO crystal-control
transmitters and uses advanced helically-filtered
receivers, too. Supporting up to 64 user codes
and 8 16 relays, the GEM-P1664 comes in two
configurations suitable for
EN50131-1
and/or
CE installations
. This Gem control features easy
“Self-Programming Plus” keypad programming
(for all zones), which includes new alpha
keypad question-prompts, even for setting test
timer, fire zones and exit/entry and follower
zones. Additionally, the panel can be remote
up/downloaded using easy-to-use NAPCO
Quickloader Software (V5.0 or greater) with true
Windows-style functionality, including cut/paste,
drop/drag, etc.
FEATURES
•
8 Hardwire/Wireless Zones on board
•
Up to 64 zones with multiplex expansion
including 2 two 2-wire fire zones
•
With multiplexing, can accommodate up to
64 EOL zones (from custom alpha keypads or
multiplex modules)
•
EZ Programming2 More comprehensive,
menu-driven programming for all zones plus
test timer.
•
Up to 64 user codes
•
Up to 4 areas
•
3 on-board outputs, up to16 external relay
outputs (RM3008s).
•
Up to 2 NAPCO helically-filtered, crystal-
control RF receivers
•
Interior bypass group with programmable
automatic interior bypass
•
600 event log
•
Auto Arm
•
Uses up to 7 of any of the Classic/RP- or K-
Series Stay & Away keypads
•
Programmable telephone line cut supervision
with delay
•
3 Keypad panics (F, P, A)
•
Supports all major communicator formats,
including: 4/2, SIA, 4+2 and Point ID, plus
pager
•
Backup/double/split reporting; three 20-digit
telephone numbers
•
Dynamic battery test
•
Reports alarms, restores and troubles by zone.
•
2 programmable entry delay times
•
Chime by zone
•
8 EOL burglary zones programmable for area,
E/E delay, interior, follower, day zone, chime,
fire options, sensor watch, swinger shutdown,
cross zoning , etc.
•
Supports series zone doubling and Loop
supervision using double EOL resistors
(feature requires use of GEM-EZM4/8
Multiplex Modules)
•
Multiplex Expandability with GEM EZM4/8 or
GEM EZM8 zone expansion modules
•
Quickloader up/downloading, including
unique unattended method
•
Choice of RF receivers
•
Partitioning by area
•
Event log with open/close suppression
•
Event log viewable at keypad (total log,
burglar alarm log, fire alarm log, system
trouble log, o/c log)
•
Cellphone-style keypad programming of zone
descriptions ( text)
•
Programmable 50Hz Clock Setting
•
Programmable Daylight Savings Time
•
Programmable Security Bypass (code required
for bypass)
•
Un-Bypassing while disarmed (code required)
•
Temperature Display at Keypad (-30 to 60
0
C
Celsius or -22 to 140
0
F Fahrenheit) with
optional GEM-TEMP64 Indoor/Outdoor
Temperature Sensor (Note: Keypad
Temperature Display replaces Date on Display)
•
Programmable High/Low Temperature Alarm
Reporting (requires feature enabled; zone 6)
•
24 Hour day zone trouble
•
Programmable security blocking of keypad
display messages –Informational displays
made visible contingent on user’s assigned
area(s) within system
•
Programmable Swinger Shutdown (2 or 3
activations – selectable)
•
Zone Anding/Cross Zoning (Grouping of zones
in which sequential zone activation is required
to generate an alarm)
SPECIFICATIONS
•
Environmental Classification: Class I (+5C to +40C),
Class II (-10C to +40C) and Class III (-25C to +50C)
•
Input power: 16.5VAC via Class 2 plug-in 20VA, 40VA
or 50VA transformer
•
Loop voltage: 10-13VDCdc
•
Loop current: 32.5mA with 2.2k ohm EOLR; 5mA for
2-wire fire
•
Loop resistance: 300 ohm max.; 50 ohm max for
2-wire fire
•
Aux & remote power: 12VDC regulated (11.7 to
12.5VDC)
•
Maximum Combined standby current: 650mA
•
Maximum Alarm current: 2A
•
Burg. voltage output: 1
•
Programmable negative outputs: 2
•
Loop response 750ms, programmable 50ms to
2,000ms
POWER
(With Type A Power Supply):
Grades 1 and 2 Installations with 4AH battery:
Maximum combined standby current: 210mA
Maximum combined standby current and alarm current:
650mA
Grades 1 and 2 installations with 7AHbattery:
Maximum combined standby current is: 460mA
Maximum combined standby current and alarm current:
500mA
Grade 3 installations (requires 7AH battery):
Maximum combined standby current is : 110mA
Maximum combined standby current and alarm current:
500mA
ORDERING INFORMATION
GEM-P1664EX Control Panel
suitable for use
in EN50131-1 Installations (transformer not
supplied).
GEM-P1664EX-230
Control panel, as above,
prewired with transformer (included) suitable for
use in EN50131-1 CE installations., CE marked.
PCD2000 NAPCO QUICKLOADER
®
Up/
Downloading Software For panel programming,
requires version 5.0 or greater. (Windows-
based).
GEM-RP1CAe2
Deluxe Custom Alphanumeric
Dual-Line Display Keypad with built in 4-Zone
Expansion Module. Classic NAPCO user
functionality. (New Black and White Decorator
Styling). (Firmware Version 9A+)
GEM-K1CA,
as above, with STAY and AWAY
user functionality. (Firmware Version 9A+)
GEM-TEMP64
Optional temperature sensor,
for use with either of the two keypads above,
programmable for celsius or fahrenheit. Indoor
or outdoor temperature display at keypad.
GEM-RP2ASe2
Alpha/Icon Keypad (Version 7
f support required).
GEM-K2AS
, as above, with STAY and AWAY
user functionality. (Version 7 f support
required).
GEM-RP3DGTL
Digital Keypad (Version 3
f support required).
GEM-K3DGTL
, as above, with STAY and AWAY
user functionality. (Version 3 f support
required).
GEM-EZM4/8
Mulitplex Module for 4 to 8 zones
expansion (supports series zone doubling and
loop supervision using double EOL resistors).
GEM-EZM8
8-Zone Mulitplex Module
Choice of NAPCO Wireless Receivers & Full
Range of NAPCO GEM or Libra Wireless
Transmitters (consult manual for selection for
your region’s frequency):
GEM-K4RF
Fixed English Language Display
Keypad with 32Pt. Built-in Wireless Receiver
(Version 2 f).
GEM-K4RF-SPAN
Spanish Language version of
above.
Note: Other language versions, also available:
Call NAPCO International Sales for info.
LIBRA RECV255-433
255 point receiver
LIBRA RECV8-433
8 point receiver
LIBRA-REC16433
Wireless 16 Point Receiver
LIBRAREC96433
Wireless 96 Point Receiver
LIBRA-TRANS433
Wireless Door Contact
LIBRA-PIR433
Wireless PIR
LIBRA-KEYF433
Wireless KeyFob
LIBRA-SMK433
Wireless Smoke Detector
LIBRA-GB433
Wireless Glass Break Sensor
GEM-RECV255
Wireless Receiver, 96 Zones
GEM-RECV96
Wireless Receiver, 96 Zones
GEM-RECV16
Wireless Receiver, 16 Zones
GEM-RECV8
Wireless Receiver, 8 Zones
GEM-TRANS2
Window/Door Transmitter, 2-Pt
GEM-RTRANS
Recessed Window/Door
Transmitter
GEM-KEYF
Key Fob Transmitter
GEM-SMK
Wireless Smoke Detector
GEM-PIR
Wireless PIR
GEM-PIRPET
Wireless Pet Immune Transmitter
GEM-DT
Wireless Dual-Technology Sensor
GEM-GB
Wireless Glass-Break Detector
WI1388
Instruction/Programming Manual
WI1386
Instruction/Programming Manual with
RP1/K1 Keypads
WI1418
GEM-EZM4/8 Zone Expansion with
GEM-P1664 Control
333 Bayview Ave., Amityville, NY, USA 11701
+1.631.842.9400
•
+1 (631) 842-2382 fax
www.napcosecurity.com
NASDAQ: NSSC
email: [email protected]
A497 © NAPCO, 6/05
Preliminary specifications subject to change.
GEM-
P1664